What does H-O make for humanoid robot batteries?
Five parts H-O cuts for humanoid battery packs: dielectric sheets, cell compression pads, mica barrier sheets, lid gaskets and vent-mounting gaskets. Cell format, voltage and the pack safety plan decide which belong in yours. A material rating never replaces pack-level testing.
Reviewed by H-O engineering·
Sources and how to read the evidence
Published application context: Figure documents insulating potting and a flame-arrestor vent; Rogers documents EVExtend cell pressure-management foams. These are different constructions. Neither source establishes Figure’s use of PORON, mica or aerogel. A protective adhesive vent is not automatically a flame arrestor.
Pick the part. See the grade.
Select a part to see its job, the catalog grade we start with, and how strong the evidence is.








Cell-top & busbar dielectric sheets
Insulates cell tops and busbars from the enclosure and from each other.
Start with220 °C aramid paper or polyimide film with high dielectric strength; die-cut or fold-and-score to the module.
Inter-cell compression pads
Holds pouch or prismatic cells inside a controlled pressure window as they swell and age.
Start withMade for EV cell compression: flat force curve and low compression set over life. Cylindrical-cell packs do not need it.
Module & under-lid barrier sheets
Slows heat moving from one module to the next in a thermal event.
Start withMica sheet is the established EV thermal-runaway containment material. Cut flat with holes and tabs; flame-rated adhesive where specified. Thin aerogel cell-to-cell barriers to order.
High-voltage insulation at temperature
Dielectric barrier where voltage and temperature are both high.
Start withMica-filled aramid paper for high-voltage dielectric duty. It is an insulator, not a thermal-runaway barrier on its own.
Lid & door gaskets
Seals the pack lid or swap door against dust and splash at low closure force.
Start withUL 94 V-0 silicone foam, –55 to 200 °C; HT-870 for low flange load, HT-800 where more load is available.
Protective vent + mounting gasket
Equalizes pressure in a sealed pack while blocking water and dust.
Start withIP64 to IP68 adhesive vents; H-O die-cuts the mounting gasket. Pressure equalization only, not sized for thermal-runaway gas.
BMS & DC-DC thermal pads
Moves heat from the BMS and DC-DC boards into the enclosure wall.
Start withSoft gap pad for uneven boards; Sil-Pad where the pad must also insulate.
Define the operating limits
Start with the constraints that govern thickness, material choice and assembly behavior. These nine inputs decide the grade.
Heat path
- Cell-to-cell and module-to-lid gaps
- BMS and DC-DC heat load
- Thermal-propagation design intent
Electrical isolation
- Working and transient voltage
- Barrier thickness available
- Busbar and cell-top geometry
Mechanical fit
- Cell format and pressure window
- Lid flange and closure force
- Vent position and ingress target
Grade data sheets give properties under test conditions. Suitability at your interface is confirmed on the assembly.
Designed for assembly
Loose parts, adhesive-backed components or kiss-cut carriers to match your build sequence.
Illustrative part formats · positions vary by design

Electrical insulation
Aramid-paper slot liners & polyimide film barriers

Thermal materials
Dielectric thermal pads & encapsulated graphite spreaders

Gaskets & cushioning
Silicone-foam static gaskets & PORON® kiss-cut pads

Barriers & vents
Mica & aerogel barriers, compression pads & adhesive vents
Review the technical details
Explore the zones on the robot, compare material families and inspect the supporting references.

01Dielectric isolation: cell tops, busbars, module-to-enclosure
Related technical evidence+
What to define first
Specify working and transient voltage, dielectric withstand, temperature and flammability requirements. Determine creepage and clearance from the applicable insulation-coordination design, including edges and cut-outs.
Materials H-O converts
How H-O makes it
Die/flash cut at high count, PSA lamination, inspection to the agreed requirements.
Sources
- Figure: disclosed F.03 battery construction and safety testingfigure.ai
- The pack enclosure is the structural torso with multiple fused bussespatents.google.com
- Electrical-insulation families for motors, power electronics and related equipmentqnityelectronics.com
- H-O's own busbar insulation resourceh-oproducts.com
Watch-outs
PET is polyester; Formex GK is polypropylene. Select each paper, film or sheet for the actual electrical and temperature requirements. These families are not a named robot OEM bill of materials.
02Cell pressure-management pads (architecture-dependent)
Humanoid context+
What to define first
Use the cell maker's allowable pressure and expansion window. Review compression-force behavior, stress relaxation, thickness and temperature across the cell life.
Materials H-O converts
How H-O makes it
Die/flash/waterjet cut, lamination.
Sources
Watch-outs
Cell compression pads are architecture-dependent. Cylindrical, pouch and prismatic cells do not share one pad specification.
03Thermal-propagation & flame barriers
Humanoid context+
What to define first
Define the fault scenario, exposure, available thickness and mechanical support. Evaluate the complete barrier construction in the pack's abuse and propagation test plan.
Materials H-O converts
How H-O makes it
Die/waterjet cut, laminate with FR PSA, dust and edge controls, part identification to the agreed requirements.
Sources
Watch-outs
Mica, ceramic, aerogel and ProCell cellular-silicone barriers are different constructions. UL 94 material data does not establish propagation protection; Figure’s disclosed potting system does not verify use of these sheet barriers.
04Static pack sealing & pressure-equalization venting
Related technical evidence+
What to define first
Define enclosure ingress requirements, flange compression, temperature and service cycles. Size protective vent airflow and water-entry resistance to the enclosure and pressure cycle.
Materials H-O converts
How H-O makes it
Die/laser cut, PSA lamination. Vents converted/integrated per Gore format.
Sources
- Autonomous 3-minute hot-swap of dual 48 V packs (cycling)ubtrobot.com
- Boston Dynamics: published robot specificationsbostondynamics.com
- Figure: disclosed F.03 battery construction and safety testingfigure.ai
- Silicone foam static-seal propertiesrogerscorp.com
- Protective adhesive vents equalize pressure and resist ingress in sealed enclosuresgore.com
Watch-outs
An ordinary ePTFE protective vent is not a flame arrestor. The connector's molded seal and a flat enclosure gasket serve different interfaces.
05BMS / DC-DC / power-electronics interfaces
Related technical evidence+
What to define first
Define the BMS or converter heat path, board clearances and allowable contact pressure. Verify the selected TIM's dielectric properties and magnetics insulation against the electrical design.
Materials H-O converts
How H-O makes it
Die cutting, lamination, kitting.
Sources
- Low-voltage conversion and fused power distribution live inside the pack enclosurepatents.google.com
- H-O drive-interface selection guide (converter context)h-oproducts.com
- Dielectric TIM ratingsh-oproducts.com
Watch-outs
H-O supplies converted sheet and film interfaces. Select conductivity and thickness from the stack-up; dispensing and potting require a separate process.
06Wireless-charging & charge-port interfaces
Related technical evidence+
What to define first
Specify dielectric separation, wear, heat flow and ingress requirements around charging contacts or coils. Preserve the charging system's magnetic and electrical clearances.
Materials H-O converts
How H-O makes it
Die cutting, lamination.
Sources
Watch-outs
Coil, window and contact interfaces follow the charging supplier's design; the illustration does not identify a named OEM material stack.
Compare material options.
Compare application fit and limitations. Evidence labels describe the scope of the references; grade and assembly validation are still required.
Compare material families · use when, not when, confidence+
| Material family | Use when | Not when | Evidence context | H-O page |
|---|---|---|---|---|
| Nomex / aramid / NMN / NKN | Electrical/thermal class and geometry support paper/laminate insulation | Grade and thickness must fit the complete insulation system | Related technical evidence | View page → |
| Polyimide / Kapton film (grade-specific) | Thin high-temperature electrical insulation is needed | Thermal and electrical properties vary by grade; verify the current datasheet | Related technical evidence | View page → |
| PET polyester film / Formex GK polypropylene sheet | Temperature/electrical/flame requirements fit the film | Not where polyimide/aramid is required | Related technical evidence | PET tape example → |
| Dielectric thermal-interface pads (grade-specific) | Compliant thermal path with known pressure/thickness | Verify dielectric properties by grade; not every TIM or SIL PAD product is insulating | Humanoid context | View page → |
| BISCO HT-800 / HT-870 / BF-1000 silicone foam | Static gasket needs match closure force, thickness, temperature, environment | Not a cell-to-cell runaway barrier by default | Related technical evidence | View page → |
| PORON EVExtend | Pouch or prismatic cell design requires a specified pressure window | Pressure-management needs depend on cell format and pack architecture | Humanoid context | View page → |
| Mica, ceramic and aerogel barriers; specialty silicone barriers (ProCell EV Firewall) | Battery safety design and abuse testing support the construction | Do not replace qualification with UL 94 claims | Related technical evidence | View page → |
| ePTFE protective vents (Gore) | Sealed enclosure pressure cycling/condensation requires venting | Pressure-equalization venting does not establish flame arrest or emergency pressure relief | Related technical evidence | View page → |
| Acrylic foam / transfer / LSE PSA | Substrate, surface energy, temperature, outgassing, removability validated | Validate adhesion on the actual substrate, finish and environment | Related technical evidence | View page → |
| Protective films / masking / liners | Manufacturing consumable and protective interfaces | Select for the protection stage, removal method and surface compatibility | Related technical evidence | View page → |
Technical sources and design context
Manufacturer references below verify material functions and product distinctions. They do not identify grades used by a humanoid OEM; candidate stacks require application qualification.
Battery and power-system material questions.
Which converted materials can be evaluated for humanoid robot batteries?
+
Candidate interfaces include dielectric films, cell pressure-management pads, thermal pads, barrier layers and static enclosure gaskets. Cell format, electrical design, cooling and fault response determine the construction; the same set of parts does not belong in every pack.
Does every humanoid battery need cell compression pads?
+
Cell pressure-management pads are architecture-dependent. Use the cell manufacturer’s allowable pressure, expansion and service-life requirements; cylindrical, pouch and prismatic designs can need different approaches.
Does a flame-rated sheet certify battery thermal-propagation protection?
+
No. Material flammability data does not establish pack-level propagation performance. Evaluate the full barrier, venting and enclosure construction through the battery system’s safety and abuse-test program.
What does H-O Products supply for this application?
+
H-O converts films, foams, tapes and laminates into parts to drawing. Share the geometry, material requirements, quantity and inspection needs for review. The robot or subsystem designer remains responsible for material qualification and system performance.
What is a cell compression pad and when does a humanoid battery need one?
+
A compression pad is a die-cut foam layer between pouch or prismatic cells that keeps cell pressure inside the window the cell maker specifies as cells swell and age. PORON® EVExtend® 4701-43 is designed for this duty. Cylindrical-cell packs usually need a different approach.
Which thermal-propagation barrier sheets can H-O die-cut?
+
Mica barrier sheets are the established EV choice. We cut them flat to module and under-lid geometry, with holes, tabs and flame-rated adhesive where specified. Nomex® 818 aramid-mica paper adds a high-voltage dielectric where mica is needed in a thin paper form; it is an insulator, not a barrier on its own. Thin aerogel cell-to-cell barriers can be sourced to order. Propagation performance is established by your pack abuse testing, not by the sheet.
Can H-O supply the pressure-equalization vent for a sealed battery enclosure?
+
Yes. We supply GORE® adhesive, snap-in and screw-in protective vents and die-cut the gasket that mounts them. A protective vent balances pressure and blocks water; it is not a flame arrestor or an emergency pressure-relief device.
Bring us the interface.
Send the drawing, operating conditions and expected quantities. We review material and converting options and come back with a quote.
- Cell format and allowable pressure window
- Working and transient voltage
- Barrier thickness available
- Lid flange and closure force
- Abuse-test plan references
- Annual quantity