Humanoid robotics  /  Battery & power

Materials for humanoid battery packs

Dielectric sheets, compression pads, mica barriers and gaskets for pack modules and enclosures.

Who we've worked with

  • University robotics teams
  • Robotics R&D labs and think tanks
  • World-leading industrial robot manufacturers
  • ISO 9001:2015 certified organization
01Quick answer

What does H-O make for humanoid robot batteries?

Five parts H-O cuts for humanoid battery packs: dielectric sheets, cell compression pads, mica barrier sheets, lid gaskets and vent-mounting gaskets. Cell format, voltage and the pack safety plan decide which belong in yours. A material rating never replaces pack-level testing.

Sources and how to read the evidence

Published application context: Figure documents insulating potting and a flame-arrestor vent; Rogers documents EVExtend cell pressure-management foams. These are different constructions. Neither source establishes Figure’s use of PORON, mica or aerogel. A protective adhesive vent is not automatically a flame arrestor.

Evidence context · assembly validation required
Humanoid contextA published source describes this function in a humanoid robot
Related technical evidenceMaterial information or a related application; review the cited scope
Design-dependent candidateA candidate only; your robot architecture decides whether it applies
Find the part inside

Pick the part. See the grade.

Select a part to see its job, the catalog grade we start with, and how strong the evidence is.

Studio view of the die-cut parts inside a humanoid battery module: Nomex cell-top sheet, PORON compression pad, mica barrier, aramid-mica HV insulation, lid gasket, vent with gasket and BMS thermal pads
Concept view · not an assembly drawing

Cell-top & busbar dielectric sheets

Insulates cell tops and busbars from the enclosure and from each other.

Start with

220 °C aramid paper or polyimide film with high dielectric strength; die-cut or fold-and-score to the module.

Request a quote for this part →

Inter-cell compression pads

Holds pouch or prismatic cells inside a controlled pressure window as they swell and age.

Start with

Made for EV cell compression: flat force curve and low compression set over life. Cylindrical-cell packs do not need it.

Request a quote for this part →

Module & under-lid barrier sheets

Slows heat moving from one module to the next in a thermal event.

Start with

Mica sheet is the established EV thermal-runaway containment material. Cut flat with holes and tabs; flame-rated adhesive where specified. Thin aerogel cell-to-cell barriers to order.

Proven in similar uses
Request a quote for this part →

High-voltage insulation at temperature

Dielectric barrier where voltage and temperature are both high.

Start with

Mica-filled aramid paper for high-voltage dielectric duty. It is an insulator, not a thermal-runaway barrier on its own.

Depends on your design
Request a quote for this part →

Lid & door gaskets

Seals the pack lid or swap door against dust and splash at low closure force.

Start with

UL 94 V-0 silicone foam, –55 to 200 °C; HT-870 for low flange load, HT-800 where more load is available.

Proven in similar uses · Rogers: BISCO® HT-800 data
Request a quote for this part →

Protective vent + mounting gasket

Equalizes pressure in a sealed pack while blocking water and dust.

Start with

IP64 to IP68 adhesive vents; H-O die-cuts the mounting gasket. Pressure equalization only, not sized for thermal-runaway gas.

Proven in similar uses · Gore: protective adhesive vents
Request a quote for this part →

BMS & DC-DC thermal pads

Moves heat from the BMS and DC-DC boards into the enclosure wall.

Start with

Soft gap pad for uneven boards; Sil-Pad where the pad must also insulate.

Request a quote for this part →
Before material selection

Define the operating limits

Start with the constraints that govern thickness, material choice and assembly behavior. These nine inputs decide the grade.

Heat path

  1. Cell-to-cell and module-to-lid gaps
  2. BMS and DC-DC heat load
  3. Thermal-propagation design intent

Electrical isolation

  1. Working and transient voltage
  2. Barrier thickness available
  3. Busbar and cell-top geometry

Mechanical fit

  1. Cell format and pressure window
  2. Lid flange and closure force
  3. Vent position and ingress target

Grade data sheets give properties under test conditions. Suitability at your interface is confirmed on the assembly.

Supplied formats

Designed for assembly

Loose parts, adhesive-backed components or kiss-cut carriers to match your build sequence.

Illustrative part formats · positions vary by design

Aramid-paper slot liners & polyimide film barriers

Electrical insulation

Aramid-paper slot liners & polyimide film barriers

Dielectric thermal pads & encapsulated graphite spreaders

Thermal materials

Dielectric thermal pads & encapsulated graphite spreaders

Silicone-foam static gaskets & PORON® kiss-cut pads

Gaskets & cushioning

Silicone-foam static gaskets & PORON® kiss-cut pads

Mica & aerogel barriers, compression pads & adhesive vents

Barriers & vents

Mica & aerogel barriers, compression pads & adhesive vents

Technical reference

Review the technical details

Explore the zones on the robot, compare material families and inspect the supporting references.

Robot hand holding a battery pack
01

Dielectric isolation: cell tops, busbars, module-to-enclosure

Related technical evidence+

What to define first

Specify working and transient voltage, dielectric withstand, temperature and flammability requirements. Determine creepage and clearance from the applicable insulation-coordination design, including edges and cut-outs.

Materials H-O converts

How H-O makes it

Die/flash cut at high count, PSA lamination, inspection to the agreed requirements.

Watch-outs

PET is polyester; Formex GK is polypropylene. Select each paper, film or sheet for the actual electrical and temperature requirements. These families are not a named robot OEM bill of materials.

02

Cell pressure-management pads (architecture-dependent)

Humanoid context+

What to define first

Use the cell maker's allowable pressure and expansion window. Review compression-force behavior, stress relaxation, thickness and temperature across the cell life.

Materials H-O converts

How H-O makes it

Die/flash/waterjet cut, lamination.

Watch-outs

Cell compression pads are architecture-dependent. Cylindrical, pouch and prismatic cells do not share one pad specification.

03

Thermal-propagation & flame barriers

Humanoid context+

What to define first

Define the fault scenario, exposure, available thickness and mechanical support. Evaluate the complete barrier construction in the pack's abuse and propagation test plan.

Materials H-O converts

How H-O makes it

Die/waterjet cut, laminate with FR PSA, dust and edge controls, part identification to the agreed requirements.

Watch-outs

Mica, ceramic, aerogel and ProCell cellular-silicone barriers are different constructions. UL 94 material data does not establish propagation protection; Figure’s disclosed potting system does not verify use of these sheet barriers.

04

Static pack sealing & pressure-equalization venting

Related technical evidence+

What to define first

Define enclosure ingress requirements, flange compression, temperature and service cycles. Size protective vent airflow and water-entry resistance to the enclosure and pressure cycle.

Materials H-O converts

How H-O makes it

Die/laser cut, PSA lamination. Vents converted/integrated per Gore format.

Watch-outs

An ordinary ePTFE protective vent is not a flame arrestor. The connector's molded seal and a flat enclosure gasket serve different interfaces.

05

BMS / DC-DC / power-electronics interfaces

Related technical evidence+

What to define first

Define the BMS or converter heat path, board clearances and allowable contact pressure. Verify the selected TIM's dielectric properties and magnetics insulation against the electrical design.

Materials H-O converts

How H-O makes it

Die cutting, lamination, kitting.

Watch-outs

H-O supplies converted sheet and film interfaces. Select conductivity and thickness from the stack-up; dispensing and potting require a separate process.

06

Wireless-charging & charge-port interfaces

Related technical evidence+

What to define first

Specify dielectric separation, wear, heat flow and ingress requirements around charging contacts or coils. Preserve the charging system's magnetic and electrical clearances.

Materials H-O converts

How H-O makes it

Die cutting, lamination.

Watch-outs

Coil, window and contact interfaces follow the charging supplier's design; the illustration does not identify a named OEM material stack.

05Material matrix

Compare material options.

Compare application fit and limitations. Evidence labels describe the scope of the references; grade and assembly validation are still required.

Compare material families · use when, not when, confidence
+
Material familyUse whenNot whenEvidence contextH-O page
Nomex / aramid / NMN / NKNElectrical/thermal class and geometry support paper/laminate insulationGrade and thickness must fit the complete insulation systemRelated technical evidenceView page →
Polyimide / Kapton film (grade-specific)Thin high-temperature electrical insulation is neededThermal and electrical properties vary by grade; verify the current datasheetRelated technical evidenceView page →
PET polyester film / Formex GK polypropylene sheetTemperature/electrical/flame requirements fit the filmNot where polyimide/aramid is requiredRelated technical evidencePET tape example →
Dielectric thermal-interface pads (grade-specific)Compliant thermal path with known pressure/thicknessVerify dielectric properties by grade; not every TIM or SIL PAD product is insulatingHumanoid contextView page →
BISCO HT-800 / HT-870 / BF-1000 silicone foamStatic gasket needs match closure force, thickness, temperature, environmentNot a cell-to-cell runaway barrier by defaultRelated technical evidenceView page →
PORON EVExtendPouch or prismatic cell design requires a specified pressure windowPressure-management needs depend on cell format and pack architectureHumanoid contextView page →
Mica, ceramic and aerogel barriers; specialty silicone barriers (ProCell EV Firewall)Battery safety design and abuse testing support the constructionDo not replace qualification with UL 94 claimsRelated technical evidenceView page →
ePTFE protective vents (Gore)Sealed enclosure pressure cycling/condensation requires ventingPressure-equalization venting does not establish flame arrest or emergency pressure reliefRelated technical evidenceView page →
Acrylic foam / transfer / LSE PSASubstrate, surface energy, temperature, outgassing, removability validatedValidate adhesion on the actual substrate, finish and environmentRelated technical evidenceView page →
Protective films / masking / linersManufacturing consumable and protective interfacesSelect for the protection stage, removal method and surface compatibilityRelated technical evidenceView page →
No material family on this page matches that filter.
06Engineering FAQ

Battery and power-system material questions.

Which converted materials can be evaluated for humanoid robot batteries?

+

Candidate interfaces include dielectric films, cell pressure-management pads, thermal pads, barrier layers and static enclosure gaskets. Cell format, electrical design, cooling and fault response determine the construction; the same set of parts does not belong in every pack.

Does every humanoid battery need cell compression pads?

+

Cell pressure-management pads are architecture-dependent. Use the cell manufacturer’s allowable pressure, expansion and service-life requirements; cylindrical, pouch and prismatic designs can need different approaches.

Does a flame-rated sheet certify battery thermal-propagation protection?

+

No. Material flammability data does not establish pack-level propagation performance. Evaluate the full barrier, venting and enclosure construction through the battery system’s safety and abuse-test program.

What does H-O Products supply for this application?

+

H-O converts films, foams, tapes and laminates into parts to drawing. Share the geometry, material requirements, quantity and inspection needs for review. The robot or subsystem designer remains responsible for material qualification and system performance.

What is a cell compression pad and when does a humanoid battery need one?

+

A compression pad is a die-cut foam layer between pouch or prismatic cells that keeps cell pressure inside the window the cell maker specifies as cells swell and age. PORON® EVExtend® 4701-43 is designed for this duty. Cylindrical-cell packs usually need a different approach.

Which thermal-propagation barrier sheets can H-O die-cut?

+

Mica barrier sheets are the established EV choice. We cut them flat to module and under-lid geometry, with holes, tabs and flame-rated adhesive where specified. Nomex® 818 aramid-mica paper adds a high-voltage dielectric where mica is needed in a thin paper form; it is an insulator, not a barrier on its own. Thin aerogel cell-to-cell barriers can be sourced to order. Propagation performance is established by your pack abuse testing, not by the sheet.

Can H-O supply the pressure-equalization vent for a sealed battery enclosure?

+

Yes. We supply GORE® adhesive, snap-in and screw-in protective vents and die-cut the gasket that mounts them. A protective vent balances pressure and blocks water; it is not a flame arrestor or an emergency pressure-relief device.

Start with your drawing

Bring us the interface.

Send the drawing, operating conditions and expected quantities. We review material and converting options and come back with a quote.

What to send us
  • Cell format and allowable pressure window
  • Working and transient voltage
  • Barrier thickness available
  • Lid flange and closure force
  • Abuse-test plan references
  • Annual quantity
Quote request

Get a battery pack parts quote

Send the drawing, operating conditions and quantities. We typically respond within one business day with a material recommendation, prototype lead time and converting options.

We've worked with university robotics teams, R&D labs and think tanks, and some of the world's leading industrial robot manufacturers.

Contact
Company address
Your job
Part & quantity
Typical response in one business day. 24-hour prototypes on in-house materials; otherwise samples typically 3–5 business days; production in about 2 weeks. Made-to-order; MOQ varies by material and part.
Engineered Materials. Advanced Converting. · Winsted, CT

Concept application guide. H-O Products converts and supplies materials to your drawing; it does not design, build or certify humanoid robots or their subsystems. Illustrations show where a converted part can sit, not a validated OEM assembly. No claim is made that any named robot maker uses any named material. Source context labels describe the cited evidence, not qualification. Humanoid context identifies a published robot function or requirement. Related technical evidence refers to material information or an analogous application; verify the cited scope. Design-dependent candidate requires a specific design review. Grade-specific data and assembly testing govern selection. Brand names are trademarks of their respective owners.