Humanoid robotics  /  EMI shielding & isolation

Shielding and isolation for humanoid robots

Conductive gaskets, foil shield wraps and dielectric barriers for shielded enclosures and busbars.

Who we've worked with

  • University robotics teams
  • Robotics R&D labs and think tanks
  • World-leading industrial robot manufacturers
  • ISO 9001:2015 certified organization
01Quick answer

What does H-O make for humanoid robot shielding and isolation?

Four parts H-O cuts for shielding and isolation: conductive seam gaskets, foil shield wraps, ESD pads and fold-and-score dielectric barriers. Start with the coupling path, the frequency range and the grounding plan. A conductive gasket never replaces a dielectric barrier.

Sources and how to read the evidence

Published application context: Molex describes humanoid interconnect constraints; 3M documents conductive gasket tape and EMI absorber materials. These establish distinct electronics functions, not a specific robot’s shielding grade or attenuation. Conductive shielding does not provide dielectric isolation.

Evidence context · assembly validation required
Humanoid contextA published source describes this function in a humanoid robot
Related technical evidenceMaterial information or a related application; review the cited scope
Design-dependent candidateA candidate only; your robot architecture decides whether it applies
Find the part inside

Pick the part. See the grade.

Select a part to see its job, the catalog grade we start with, and how strong the evidence is.

Studio view of the EMI and isolation parts for a humanoid electronics enclosure: conductive seam gasket, flange gasket, ESD pads, copper and aluminum foil shields, grounding tabs, Kapton barrier and absorber pieces
Concept view · not an assembly drawing

Enclosure seam gasket (compute, radio)

Bridges the lid-to-housing seam electrically so the enclosure stays a continuous shield.

Start with

Nickel-graphite conductive silicone, a soft 30 Shore A solid (not a foam). Low closure force; die-cuts into frames and strips.

Proven in similar uses · BISCO® EC-2130 data
Request a quote for this part →

Firmer conductive flange gasket

Flat conductive gasket where higher contact pressure or a firmer sheet is specified.

Start with

Nickel-graphite filled silicone sheet with third-party shielding data; ask H-O for the grade sheet.

Request a quote for this part →

ESD static-drain pads

Bleeds static charge from covers and sensor housings. Not an EMI shield.

Start with

Carbon-filled silicone at about 5 Ω·cm: conductive enough for static drain, far too resistive for shielding.

Depends on your design
Request a quote for this part →

Shield wrap inside covers & around bundles

Adds a foil shield layer to a plastic cover or a cable bundle.

Start with

Foil/PET laminates with non-conductive adhesive: a shield wrap, not a grounding tape. A-35’s 95 dB figure is far-field at 100 MHz.

Request a quote for this part →

Shield termination & grounding tabs

Bonds a cable shield or cover shield to chassis ground.

Start with

H-O’s stocked foil tapes have non-conductive adhesive, so termination needs a conductive-adhesive tape sourced to order or a 360° connector backshell.

Request a quote for this part →

Dielectric barriers & creepage sheets

Insulates busbars and board edges; keeps shield metal away from live parts.

Start with

Fold-and-score sheets. A conductive gasket provides bonding, not insulation; pair it with a dielectric barrier and recheck creepage and clearance.

Request a quote for this part →

Absorber pieces at a drive or radio

Damps a measured resonance at a specific frequency.

Start with

Only after an EMC scan identifies the frequency; absorbers supplement grounding and shield continuity, they do not replace them.

Depends on your design · 3M: AB7000 EMI absorbers
Request a quote for this part →
Before material selection

Define the operating limits

Start with the constraints that govern thickness, material choice and assembly behavior. These nine inputs decide the grade.

Shielding target

  1. Frequency range and attenuation
  2. Seam geometry and closure force
  3. Housing metal and finish

Electrical isolation

  1. Working voltage near shields
  2. Creepage and clearance
  3. Grounding scheme and shield termination

Mechanical fit

  1. Gasket cross-section available
  2. Cable-entry and connector cut-outs
  3. Flex exposure at terminations

Grade data sheets give properties under test conditions. Suitability at your interface is confirmed on the assembly.

Supplied formats

Designed for assembly

Loose parts, adhesive-backed components or kiss-cut carriers to match your build sequence.

Illustrative part formats · positions vary by design

Aramid-paper slot liners & polyimide film barriers

Electrical insulation

Aramid-paper slot liners & polyimide film barriers

EMI gaskets, foil tape & UHMW / polyimide harness tapes

Shielding & harness protection

EMI gaskets, foil tape & UHMW / polyimide harness tapes

Technical reference

Review the technical details

Explore the zones on the robot, compare material families and inspect the supporting references.

Robot electronics and ribbon cables under test on the bench
01

Compute & radio enclosure shielding (conductive silicone / FoF)

Related technical evidence+

What to define first

Define the interference frequency range and shielding target. Select gasket compression, closure force and surface finish for the enclosure, with corrosion-compatible contact materials.

Materials H-O converts

How H-O makes it

Die cut sheet variants, laminate, kit.

Watch-outs

Fabric-over-foam ranges include wrapped profiles and conductive-foam formats; only suitable sheet grades are candidates for die cutting. Fabric-over-foam is not inherently a weather seal.

02

Motor-drive EMI at the joint (absorbers, foil, grounding)

Related technical evidence+

What to define first

Identify coupling from the drive, switching edges and cable routing. Establish shield continuity and grounding before selecting absorbers for a measured frequency range.

Materials H-O converts

Copper / aluminum foil tapesConductive fabric tapesFrequency-specific absorber pieces

How H-O makes it

Slitting, die cutting.

Watch-outs

Absorbers supplement a specific EMC design; they do not replace grounding, cable layout or shield continuity.

03

Sensor-electronics protection (cameras, encoders, F/T, IMU)

Related technical evidence+

What to define first

Specify shielding continuity, contact pressure, sensor clearances and grounding around the conditioning electronics. Check material interaction with magnetic sensors.

Materials H-O converts

How H-O makes it

Die cut, slit.

Watch-outs

Sensor performance and calibration govern the construction. A generic shield material is not a validated OEM sensor stack.

04

Connector & feed-through interfaces (EMI + sealing where justified)

Related technical evidence+

What to define first

Define shielding and ingress requirements at the flange. Match conductive filler, binder and housing metal for corrosion behavior, closure force and service environment.

Materials H-O converts

How H-O makes it

Die/waterjet/flash cut sheet, PSA laminate. H-O does not mold or extrude profiles.

Watch-outs

H-O converts flat sheet gaskets. Conductive filler, binder and flame rating are grade-specific; SSP 502 and 2529 are not interchangeable V-0 designations. Molded profiles require a separate process.

05

Dielectric isolation & creepage

Related technical evidence+

What to define first

Determine insulation coordination from working voltage, transients, pollution conditions and geometry. Select dielectric strength, thermal rating and flammability for the specific material grade.

Materials H-O converts

How H-O makes it

Die/flash cut, fold-and-score, kit.

Watch-outs

Nominal bus voltage alone does not establish safe creepage or clearance. Conductive shield materials must remain separate from required dielectric barriers.

06

Cable-shield continuity & grounding

Related technical evidence+

What to define first

Specify where the shield terminates (connector backshell or conductive-adhesive tape, sourced to order), contact resistance, corrosion compatibility and flex exposure. Stocked foil laminates have non-conductive adhesive. Validate the assembled grounding path over the duty cycle.

Materials H-O converts

How H-O makes it

Slitting, die cutting.

Sources

Watch-outs

Foil tape is not a repair for a failed flex-cable design. Use purpose-designed terminations and flex-rated cable where motion requires them.

05Material matrix

Compare material options.

Compare application fit and limitations. Evidence labels describe the scope of the references; grade and assembly validation are still required.

Compare material families · use when, not when, confidence
+
Material familyUse whenNot whenEvidence contextH-O page
Nomex / aramid / NMN / NKNElectrical/thermal class and geometry support paper/laminate insulationGrade and thickness must fit the complete insulation systemRelated technical evidenceView page →
Polyimide / Kapton film (grade-specific)Thin high-temperature electrical insulation is neededThermal and electrical properties vary by grade; verify the current datasheetRelated technical evidenceView page →
PET polyester film / Formex GK polypropylene sheetTemperature/electrical/flame requirements fit the filmNot where polyimide/aramid is requiredRelated technical evidencePET tape example →
Conductive silicone (EC-2130) / fabric-over-foamEMI/grounding at enclosure seam without weather sealNot an environmental/weather sealRelated technical evidenceView product →
Conductive silicone / fluorosilicone sheet (grade-specific filler and flame rating)Both shielding and sealing are required and sheet geometry is appropriateFlat sheet geometry; molded or extruded profiles require a separate processRelated technical evidenceView page →
EMI absorbersFrequency-specific analysis supports absorber useNot a universal substitute for shielding/groundingDesign-dependent candidateAsk H-O →
Copper / aluminum foil tapes and foil-film laminatesShield wrap inside covers or around bundles; stocked laminates have non-conductive adhesiveVerify grounding, corrosion and fatigue behavior in the intended interfaceRelated technical evidenceView product →
Acrylic foam / transfer / LSE PSASubstrate, surface energy, temperature, outgassing, removability validatedValidate adhesion on the actual substrate, finish and environmentRelated technical evidenceView page →
No material family on this page matches that filter.
06Engineering FAQ

Shielding and isolation questions.

Which converted materials address EMI and electrical isolation in humanoid robots?

+

Conductive foam, elastomer sheet, foil tape and absorber pieces can address defined shielding or coupling problems. Polyimide, aramid and other dielectric films serve electrical-insulation functions. Select these as separate parts of the grounding and isolation design.

Does an EMI gasket also provide an environmental seal?

+

Only when the selected material and flange construction are designed and qualified for both functions. Fabric-over-foam is not inherently a weather seal; verify compression, surface contact, corrosion and ingress performance in the assembly.

Can a conductive thermal or shielding material replace a dielectric barrier?

+

No. Conductive materials cannot provide the required dielectric barrier. Verify the complete grounding, creepage, clearance and insulation design before placing them near energized parts.

What does H-O Products supply for this application?

+

H-O converts films, foams, tapes and laminates into parts to drawing. Share the geometry, material requirements, quantity and inspection needs for review. The robot or subsystem designer remains responsible for material qualification and system performance.

Which conductive gasket materials can H-O die-cut for a robot enclosure seam?

+

BISCO® EC-2130 nickel-graphite conductive silicone (a soft 30 Shore A solid) and SSP502 nickel-graphite silicone sheet are the shielding gasket grades we cut into frames and strips. BISCO® EC2265 is a carbon-filled ESD grade for static drain, not shielding. Copper and aluminum foil/PET laminates serve as shield wraps; their adhesive is non-conductive, so conductive-adhesive tape for shield termination is sourced to order. Molded and extruded profiles are outside our scope.

Does H-O supply EMI absorbers?

+

Absorber sheet is available for die-cut pieces when your EMC analysis identifies a frequency-specific coupling problem. Send the frequency range and location. Absorbers supplement grounding and shield continuity rather than replace them.

How do I keep a shielding part from compromising electrical isolation?

+

Keep conductive shielding parts physically separate from dielectric barriers and respect creepage and clearance. We can laminate a dielectric film to one face of a foil or conductive gasket where the design calls for it. The isolation scheme is verified by your electrical team.

Start with your drawing

Bring us the interface.

Send the drawing, operating conditions and expected quantities. We review material and converting options and come back with a quote.

What to send us
  • Frequency range and shielding target
  • Seam geometry and closure force
  • Housing metal and finish
  • Grounding scheme
  • Working voltage for isolation barriers
  • Annual quantity
Quote request

Get an EMI and isolation parts quote

Send the drawing, operating conditions and quantities. We typically respond within one business day with a material recommendation, prototype lead time and converting options.

We've worked with university robotics teams, R&D labs and think tanks, and some of the world's leading industrial robot manufacturers.

Contact
Company address
Your job
Part & quantity
Typical response in one business day. 24-hour prototypes on in-house materials; otherwise samples typically 3–5 business days; production in about 2 weeks. Made-to-order; MOQ varies by material and part.
Engineered Materials. Advanced Converting. · Winsted, CT

Concept application guide. H-O Products converts and supplies materials to your drawing; it does not design, build or certify humanoid robots or their subsystems. Illustrations show where a converted part can sit, not a validated OEM assembly. No claim is made that any named robot maker uses any named material. Source context labels describe the cited evidence, not qualification. Humanoid context identifies a published robot function or requirement. Related technical evidence refers to material information or an analogous application; verify the cited scope. Design-dependent candidate requires a specific design review. Grade-specific data and assembly testing govern selection. Brand names are trademarks of their respective owners.