Shielding and isolation for humanoid robots
Conductive gaskets, foil shield wraps and dielectric barriers for shielded enclosures and busbars.

Who we've worked with
- University robotics teams
- Robotics R&D labs and think tanks
- World-leading industrial robot manufacturers
- ISO 9001:2015 certified organization
What does H-O make for humanoid robot shielding and isolation?
Four parts H-O cuts for shielding and isolation: conductive seam gaskets, foil shield wraps, ESD pads and fold-and-score dielectric barriers. Start with the coupling path, the frequency range and the grounding plan. A conductive gasket never replaces a dielectric barrier.
Reviewed by H-O engineering·
Sources and how to read the evidence
Published application context: Molex describes humanoid interconnect constraints; 3M documents conductive gasket tape and EMI absorber materials. These establish distinct electronics functions, not a specific robot’s shielding grade or attenuation. Conductive shielding does not provide dielectric isolation.
Pick the part. See the grade.
Select a part to see its job, the catalog grade we start with, and how strong the evidence is.








Enclosure seam gasket (compute, radio)
Bridges the lid-to-housing seam electrically so the enclosure stays a continuous shield.
Start withNickel-graphite conductive silicone, a soft 30 Shore A solid (not a foam). Low closure force; die-cuts into frames and strips.
Firmer conductive flange gasket
Flat conductive gasket where higher contact pressure or a firmer sheet is specified.
Start withNickel-graphite filled silicone sheet with third-party shielding data; ask H-O for the grade sheet.
ESD static-drain pads
Bleeds static charge from covers and sensor housings. Not an EMI shield.
Start withCarbon-filled silicone at about 5 Ω·cm: conductive enough for static drain, far too resistive for shielding.
Shield wrap inside covers & around bundles
Adds a foil shield layer to a plastic cover or a cable bundle.
Start withFoil/PET laminates with non-conductive adhesive: a shield wrap, not a grounding tape. A-35’s 95 dB figure is far-field at 100 MHz.
Shield termination & grounding tabs
Bonds a cable shield or cover shield to chassis ground.
Start withH-O’s stocked foil tapes have non-conductive adhesive, so termination needs a conductive-adhesive tape sourced to order or a 360° connector backshell.
Dielectric barriers & creepage sheets
Insulates busbars and board edges; keeps shield metal away from live parts.
Start withFold-and-score sheets. A conductive gasket provides bonding, not insulation; pair it with a dielectric barrier and recheck creepage and clearance.
Absorber pieces at a drive or radio
Damps a measured resonance at a specific frequency.
Start withOnly after an EMC scan identifies the frequency; absorbers supplement grounding and shield continuity, they do not replace them.
Define the operating limits
Start with the constraints that govern thickness, material choice and assembly behavior. These nine inputs decide the grade.
Shielding target
- Frequency range and attenuation
- Seam geometry and closure force
- Housing metal and finish
Electrical isolation
- Working voltage near shields
- Creepage and clearance
- Grounding scheme and shield termination
Mechanical fit
- Gasket cross-section available
- Cable-entry and connector cut-outs
- Flex exposure at terminations
Grade data sheets give properties under test conditions. Suitability at your interface is confirmed on the assembly.
Designed for assembly
Loose parts, adhesive-backed components or kiss-cut carriers to match your build sequence.
Illustrative part formats · positions vary by design

Electrical insulation
Aramid-paper slot liners & polyimide film barriers

Shielding & harness protection
EMI gaskets, foil tape & UHMW / polyimide harness tapes
Review the technical details
Explore the zones on the robot, compare material families and inspect the supporting references.

01Compute & radio enclosure shielding (conductive silicone / FoF)
Related technical evidence+
What to define first
Define the interference frequency range and shielding target. Select gasket compression, closure force and surface finish for the enclosure, with corrosion-compatible contact materials.
Materials H-O converts
How H-O makes it
Die cut sheet variants, laminate, kit.
Watch-outs
Fabric-over-foam ranges include wrapped profiles and conductive-foam formats; only suitable sheet grades are candidates for die cutting. Fabric-over-foam is not inherently a weather seal.
02Motor-drive EMI at the joint (absorbers, foil, grounding)
Related technical evidence+
What to define first
Identify coupling from the drive, switching edges and cable routing. Establish shield continuity and grounding before selecting absorbers for a measured frequency range.
Materials H-O converts
How H-O makes it
Slitting, die cutting.
Sources
Watch-outs
Absorbers supplement a specific EMC design; they do not replace grounding, cable layout or shield continuity.
03Sensor-electronics protection (cameras, encoders, F/T, IMU)
Related technical evidence+
What to define first
Specify shielding continuity, contact pressure, sensor clearances and grounding around the conditioning electronics. Check material interaction with magnetic sensors.
Materials H-O converts
How H-O makes it
Die cut, slit.
Sources
Watch-outs
Sensor performance and calibration govern the construction. A generic shield material is not a validated OEM sensor stack.
04Connector & feed-through interfaces (EMI + sealing where justified)
Related technical evidence+
What to define first
Define shielding and ingress requirements at the flange. Match conductive filler, binder and housing metal for corrosion behavior, closure force and service environment.
Materials H-O converts
How H-O makes it
Die/waterjet/flash cut sheet, PSA laminate. H-O does not mold or extrude profiles.
Sources
- Boston Dynamics: published robot specificationsbostondynamics.com
- Molex: connector design for humanoid robotsmolex.com
- H-O-listed conductive sheet gradesh-oproducts.com
Watch-outs
H-O converts flat sheet gaskets. Conductive filler, binder and flame rating are grade-specific; SSP 502 and 2529 are not interchangeable V-0 designations. Molded profiles require a separate process.
05Dielectric isolation & creepage
Related technical evidence+
What to define first
Determine insulation coordination from working voltage, transients, pollution conditions and geometry. Select dielectric strength, thermal rating and flammability for the specific material grade.
Materials H-O converts
How H-O makes it
Die/flash cut, fold-and-score, kit.
Sources
Watch-outs
Nominal bus voltage alone does not establish safe creepage or clearance. Conductive shield materials must remain separate from required dielectric barriers.
06Cable-shield continuity & grounding
Related technical evidence+
What to define first
Specify where the shield terminates (connector backshell or conductive-adhesive tape, sourced to order), contact resistance, corrosion compatibility and flex exposure. Stocked foil laminates have non-conductive adhesive. Validate the assembled grounding path over the duty cycle.
Materials H-O converts
How H-O makes it
Slitting, die cutting.
Sources
- chinabizinsider.com
- H-O-listed foil tapesh-oproducts.com
Watch-outs
Foil tape is not a repair for a failed flex-cable design. Use purpose-designed terminations and flex-rated cable where motion requires them.
Compare material options.
Compare application fit and limitations. Evidence labels describe the scope of the references; grade and assembly validation are still required.
Compare material families · use when, not when, confidence+
| Material family | Use when | Not when | Evidence context | H-O page |
|---|---|---|---|---|
| Nomex / aramid / NMN / NKN | Electrical/thermal class and geometry support paper/laminate insulation | Grade and thickness must fit the complete insulation system | Related technical evidence | View page → |
| Polyimide / Kapton film (grade-specific) | Thin high-temperature electrical insulation is needed | Thermal and electrical properties vary by grade; verify the current datasheet | Related technical evidence | View page → |
| PET polyester film / Formex GK polypropylene sheet | Temperature/electrical/flame requirements fit the film | Not where polyimide/aramid is required | Related technical evidence | PET tape example → |
| Conductive silicone (EC-2130) / fabric-over-foam | EMI/grounding at enclosure seam without weather seal | Not an environmental/weather seal | Related technical evidence | View product → |
| Conductive silicone / fluorosilicone sheet (grade-specific filler and flame rating) | Both shielding and sealing are required and sheet geometry is appropriate | Flat sheet geometry; molded or extruded profiles require a separate process | Related technical evidence | View page → |
| EMI absorbers | Frequency-specific analysis supports absorber use | Not a universal substitute for shielding/grounding | Design-dependent candidate | Ask H-O → |
| Copper / aluminum foil tapes and foil-film laminates | Shield wrap inside covers or around bundles; stocked laminates have non-conductive adhesive | Verify grounding, corrosion and fatigue behavior in the intended interface | Related technical evidence | View product → |
| Acrylic foam / transfer / LSE PSA | Substrate, surface energy, temperature, outgassing, removability validated | Validate adhesion on the actual substrate, finish and environment | Related technical evidence | View page → |
Technical sources and design context
Manufacturer references below verify material functions and product distinctions. They do not identify grades used by a humanoid OEM; candidate stacks require application qualification.
Shielding and isolation questions.
Which converted materials address EMI and electrical isolation in humanoid robots?
+
Conductive foam, elastomer sheet, foil tape and absorber pieces can address defined shielding or coupling problems. Polyimide, aramid and other dielectric films serve electrical-insulation functions. Select these as separate parts of the grounding and isolation design.
Does an EMI gasket also provide an environmental seal?
+
Only when the selected material and flange construction are designed and qualified for both functions. Fabric-over-foam is not inherently a weather seal; verify compression, surface contact, corrosion and ingress performance in the assembly.
Can a conductive thermal or shielding material replace a dielectric barrier?
+
No. Conductive materials cannot provide the required dielectric barrier. Verify the complete grounding, creepage, clearance and insulation design before placing them near energized parts.
What does H-O Products supply for this application?
+
H-O converts films, foams, tapes and laminates into parts to drawing. Share the geometry, material requirements, quantity and inspection needs for review. The robot or subsystem designer remains responsible for material qualification and system performance.
Which conductive gasket materials can H-O die-cut for a robot enclosure seam?
+
BISCO® EC-2130 nickel-graphite conductive silicone (a soft 30 Shore A solid) and SSP502 nickel-graphite silicone sheet are the shielding gasket grades we cut into frames and strips. BISCO® EC2265 is a carbon-filled ESD grade for static drain, not shielding. Copper and aluminum foil/PET laminates serve as shield wraps; their adhesive is non-conductive, so conductive-adhesive tape for shield termination is sourced to order. Molded and extruded profiles are outside our scope.
Does H-O supply EMI absorbers?
+
Absorber sheet is available for die-cut pieces when your EMC analysis identifies a frequency-specific coupling problem. Send the frequency range and location. Absorbers supplement grounding and shield continuity rather than replace them.
How do I keep a shielding part from compromising electrical isolation?
+
Keep conductive shielding parts physically separate from dielectric barriers and respect creepage and clearance. We can laminate a dielectric film to one face of a foil or conductive gasket where the design calls for it. The isolation scheme is verified by your electrical team.
Bring us the interface.
Send the drawing, operating conditions and expected quantities. We review material and converting options and come back with a quote.
- Frequency range and shielding target
- Seam geometry and closure force
- Housing metal and finish
- Grounding scheme
- Working voltage for isolation barriers
- Annual quantity
Get an EMI and isolation parts quote
Send the drawing, operating conditions and quantities. We typically respond within one business day with a material recommendation, prototype lead time and converting options.
We've worked with university robotics teams, R&D labs and think tanks, and some of the world's leading industrial robot manufacturers.