Humanoid robotics  /  Sealing & ingress protection

Sealing materials for humanoid robots

Panel gaskets, connector seals and protective vents for every enclosure on the robot.

Who we've worked with

  • University robotics teams
  • Robotics R&D labs and think tanks
  • World-leading industrial robot manufacturers
  • ISO 9001:2015 certified organization
01Quick answer

What does H-O make for humanoid robot enclosure sealing?

Static gaskets for robot enclosure interfaces: access-panel and lid gaskets, connector-flange seals, higher-load solid gaskets and pressure-equalization vents. Send the flange drawing, ingress target and closure force. The IP rating is earned by the enclosure, not the gasket.

Sources and how to read the evidence

Published application context: Boston Dynamics publishes Atlas ingress specifications; Rogers documents silicone-foam sealing properties and Gore documents protective adhesive vents. Atlas’s rating does not disclose its gasket grade. These industrial material functions do not establish an assembled robot’s ingress performance.

Evidence context · assembly validation required
Humanoid contextA published source describes this function in a humanoid robot
Related technical evidenceMaterial information or a related application; review the cited scope
Design-dependent candidateA candidate only; your robot architecture decides whether it applies
Find the part inside

Pick the part. See the grade.

Select a part to see its job, the catalog grade we start with, and how strong the evidence is.

Studio view of the sealing parts for a humanoid enclosure: panel gasket, AquaPro gasket, connector gaskets, solid silicone and fluorosilicone seals, fire-barrier gasket, protective vent, aperture seal and filter foam
Concept view · not an assembly drawing

Access-panel & lid gaskets

Seals torso panels, lids and compute enclosures against dust and splash.

Start with

Cellular silicone candidates for covers and lids. Compare HT-800 and extra-soft BF-1000 using grade-specific force-deflection, temperature and flammability data.

Proven in similar uses · Rogers silicone-foam selection data
Request a quote for this part →

Water-resistant foam gasket

Foam gasket that must pass a water-ingress fixture test.

Start with

Rogers reports AquaPro passing an IPX7-style fixture test; the enclosure, not the foam, earns the rating. 4701-41 is UL 94 HBF.

Proven in similar uses · Rogers: enclosure gasket examples
Request a quote for this part →

Connector-flange & feed-through gaskets

Seals connector flanges and panel cut-outs, PSA on one face.

Start with

PORON for low compression set; solid EPDM for ozone and weather exposure.

Proven in similar uses · Molex: humanoid connector design
Request a quote for this part →

Higher-load static seals

Flat gaskets where the flange load is higher or fluids are present.

Start with

Static covers only. Fluorosilicone after a fluid-compatibility review; sheet gaskets are not rotating-shaft seals.

Request a quote for this part →

Fire-barrier gasket

Where a low-smoke, fire-barrier solid is specified at a battery or hot-zone cover.

Start with

A solid silicone candidate where fire-performance requirements are specified. Review the selected thickness, supplier data, closure load and required assembly tests.

Depends on your design
Request a quote for this part →

Pressure-equalization vents

Lets the enclosure breathe as it heats and cools while blocking water and dust.

Start with

Select a protective vent using the supplier’s pressure-flow, ingress and installation data. H-O converts the mounting gasket; fault-pressure relief requires a separate component review.

Proven in similar uses · Gore: protective adhesive vents
Request a quote for this part →

Dust & light seals at sensor apertures

Very low-force seal around windows and lenses. Not a water seal.

Start with

A candidate for low-force dust and light sealing. Confirm the closure load, optical alignment and contamination requirements.

Proven in similar uses · Rogers: camera gasket materials
Request a quote for this part →

Filtered airflow at fan intakes

Keeps debris out of a forced-air path.

Start with

Reticulated foam for a forced-air filtration path. Specify pore size, pressure drop and particle-retention requirements; it is not an enclosure water seal.

Depends on your design · FXI: reticulated air-filter foam
Request a quote for this part →
Before material selection

Define the operating limits

Start with the constraints that govern thickness, material choice and assembly behavior. These nine inputs decide the grade.

Ingress target

  1. IP or test level for the enclosure
  2. Water, dust or wash-down exposure
  3. Pressure-equalization need

Flange

  1. Gap and flatness
  2. Fastener pattern and closure force
  3. Connector and feed-through cut-outs

Material limits

  1. Temperature range
  2. Flame rating required
  3. Fluids or UV exposure

Grade data sheets give properties under test conditions. Suitability at your interface is confirmed on the assembly.

Supplied formats

Designed for assembly

Loose parts, adhesive-backed components or kiss-cut carriers to match your build sequence.

Illustrative part formats · positions vary by design

Static foam gaskets and kiss-cut cushioning pads

Gaskets & cushioning

Static foam gaskets and kiss-cut cushioning pads

Technical reference

Review the technical details

Explore the zones on the robot, compare material families and inspect the supporting references.

Humanoid robot head with a sealed camera visor
01

Head & sensor housings

Related technical evidence+

What to define first

Define ingress protection, compression and low-outgassing requirements for the housing. Evaluate contamination and cleaning chemistry around optical modules.

Materials H-O converts

How H-O makes it

Die cutting, slitting or adhesive lamination to the specified part geometry; process confirmed during drawing review.

Watch-outs

Optical apertures and calibration interfaces need sensor-specific review in addition to enclosure sealing.

02

Torso electronics & compute enclosures

Humanoid context+

What to define first

Select gasket thickness and compression from flange tolerance and closure force. Review temperature, oil mist, cleaning fluids and required flammability data.

Materials H-O converts

How H-O makes it

Die cutting, slitting or adhesive lamination to the specified part geometry; process confirmed during drawing review.

Watch-outs

The complete enclosure establishes the ingress rating. Flat converted gaskets are distinct from formed-in-place or molded seals.

03

Battery enclosure lids, doors & swap interfaces

Related technical evidence+

What to define first

Account for pack access, repeated closure, flange recovery and pressure equalization. Coordinate the static seal and vent with the battery safety design.

Materials H-O converts

How H-O makes it

Die cutting, slitting or adhesive lamination to the specified part geometry; process confirmed during drawing review.

Watch-outs

Protective vents and fault-pressure relief perform different duties. Review the pack-specific sealing and venting interfaces.

04

Static actuator covers & service plates

Related technical evidence+

What to define first

Define the cover gap, fastener pattern, lubricant exposure and service temperature. Qualify compression recovery over the planned service cycles.

Materials H-O converts

How H-O makes it

Die cutting, slitting or adhesive lamination to the specified part geometry; process confirmed during drawing review.

Watch-outs

Rotary shaft seals and dynamic lip seals are separate technologies; these materials address static covers and service plates.

05

Connector panels & feed-through cut-outs

Related technical evidence+

What to define first

Specify the flange cut-out, fastener load, repeated mating environment and any grounding requirement. Keep the gasket clear of connector engagement and retention features.

Materials H-O converts

How H-O makes it

Die cutting, slitting or adhesive lamination to the specified part geometry; process confirmed during drawing review.

Watch-outs

A panel gasket supplements the connector design; it does not replace the connector supplier's molded seal.

06

Pressure equalization, venting & filtered airflow

Related technical evidence+

What to define first

Size vent airflow and water-entry resistance for enclosure volume and pressure cycling. Evaluate oil exposure and contamination; specify filter pressure drop for forced-air systems.

Materials H-O converts

How H-O makes it

Die cut filter pads and mounting gaskets as specified. Confirm the vent product, available format and installation process with its supplier.

Watch-outs

A protective ePTFE vent is not automatically a flame arrestor or grease seal. A pressure vent and an airflow filter are different components.

Material guide Sealing & ingress

Start with the interface.

Tell us what the part needs to do. Explore candidate materials, understand the tradeoffs, and carry the right questions into your engineering brief.

Start with the part explorer and the material reference below. Review silicone foam for enclosure gaskets, AquaPro for water-sealing evaluation, or protective vents for pressure equalization.

For review, bring the flange drawing, available closure force, exposure conditions, temperature range, and service schedule. Material data supports selection; the finished assembly must meet its own test requirements.

01 / YOUR INTERFACE

Early concept? Leave unknowns open. They become questions for review.

02 / YOUR STARTING POINT

Candidates to evaluate

Resolve before specification

    A starting point for engineering review. These suggestions do not establish an IP rating or qualification for a particular robot.

    Three questions worth resolving early

    How much compression?

    Review the selected grade’s force-deflection data against the flange gap, tolerances, gasket area, and available load. There is no single compression setting for every foam.

    Rogers material data & design tools ↗

    What changes with service access?

    Include recovery after opening, gasket retention, wear, and the replacement plan in your review. Validate the seal again after representative service cycles.

    Rogers recovery & relaxation information ↗

    Does the enclosure need to breathe?

    A protective vent provides a controlled air path for pressure equalization. Select the vent and its installation for your enclosure volume, environment, and ingress target.

    Gore vent selection & installation ↗
    05Material matrix

    Compare material options.

    Compare application fit and limitations. Evidence labels describe the scope of the references; grade and assembly validation are still required.

    Compare material families · use when, not when, confidence
    +
    Material familyUse whenNot whenEvidence contextH-O page
    BISCO silicone foam (HT-800 / HT-870 / BF-1000 examples)Static gasket needs match closure force, thickness, temperature, environmentNot a cell-to-cell runaway barrier by defaultRelated technical evidenceView page →
    Solid silicone / fluorosilicone sheetStatic sheet gasket where flange load and gap fit; fluorosilicone only after fluid-compatibility reviewSheet gaskets do not replace engineered rotating-shaft or reciprocating sealsRelated technical evidenceView page →
    PORON polyurethane foam (grade and recovery behavior selected)Temperature/flame/fluid conditions fit PU; long-term compression behavior suitableNot automatically in hot actuator or battery fire-barrier zonesRelated technical evidenceView page →
    Conductive silicone or fluorosilicone gasket (grade-specific)Both shielding and sealing are required and sheet geometry is appropriateFlat sheet geometry; molded or extruded profiles require a separate processRelated technical evidenceView page →
    ePTFE enclosure pressure vents (specified vent product)The specified vent meets pressure-flow, water-entry and installation requirementsRaw ePTFE sheet is not a qualified vent; ordinary enclosure vents are not battery flame arrestorsRelated technical evidenceePTFE stock reference →
    Acrylic transfer adhesive (substrate-specific)Bonding needs match adhesive, substrate finish, temperature and contamination limitsValidate adhesion on the actual substrate, finish and environmentRelated technical evidenceView page →
    EPDM sponge (grade-specific)Static sealing needs match compression, temperature and fluid exposureEPDM is not universally oil-resistant; verify the actual exposureDesign-dependent candidateView page →
    No material family on this page matches that filter.
    06Engineering FAQ

    Enclosure sealing questions.

    How are flat gaskets selected for humanoid robot enclosures?

    +

    Define the ingress target, flange gap, surface condition, fastener load and compression range. Then review temperature, cleaning fluids, lubricant exposure and service cycles. H-O converts the selected sheet or laminate to the enclosure drawing.

    Does a gasket material give an enclosure an IP rating?

    +

    No. Ingress protection depends on the complete enclosure, including gasket geometry, compression, fasteners, vents and penetrations. Verify the assembled system against its specified test requirements.

    Is a protective ePTFE vent a battery flame arrestor?

    +

    Not automatically. Protective vents balance pressure while resisting specified liquid and particle ingress. Flame arresting and fault-pressure relief are separate functions that require an appropriate component and system design.

    What does H-O Products supply for this application?

    +

    H-O converts films, foams, tapes and laminates into parts to drawing. Share the geometry, material requirements, quantity and inspection needs for review. The robot or subsystem designer remains responsible for material qualification and system performance.

    Which gasket foam seals a robot access panel with low closure force?

    +

    BISCO® BF-1000 extra-soft silicone foam seals at low compression force; PORON® 4701-15 SoftSeal suits dust and light seals rather than water. BISCO® HT-800 is the medium-firmness general choice for lids and covers. Pick thickness from the flange gap and the foam's compression curve.

    What is the difference between a protective vent and a filter foam?

    +

    A GORE® protective vent is a membrane that equalizes pressure inside a sealed enclosure while blocking water and dust. Reticulated filter foam such as FilterPore® passes forced air and traps particles in an open cooling path. They do different jobs and are specified separately.

    Can H-O apply adhesive to one side of the gasket?

    +

    Yes. We laminate pressure-sensitive adhesive to one face, die-cut the gasket and deliver it on a liner, nested or in strips, so it peels and places on the assembly line.

    Start with your drawing

    Bring us the interface.

    Send the drawing, operating conditions and expected quantities. We review material and converting options and come back with a quote.

    What to send us
    • Flange drawing with gap and fastener pattern
    • Ingress target (IP rating)
    • Closure force
    • Temperature and fluid exposure
    • Service cycles
    • Annual quantity
    Quote request

    Get a sealing and venting quote

    Send the drawing, operating conditions and quantities. We typically respond within one business day with a material recommendation, prototype lead time and converting options.

    We've worked with university robotics teams, R&D labs and think tanks, and some of the world's leading industrial robot manufacturers.

    Contact
    Company address
    Your job
    Part & quantity
    Typical response in one business day. 24-hour prototypes on in-house materials; otherwise samples typically 3–5 business days; production in about 2 weeks. Made-to-order; MOQ varies by material and part.
    Engineered Materials. Advanced Converting. · Winsted, CT

    Concept application guide. H-O Products converts and supplies materials to your drawing; it does not design, build or certify humanoid robots or their subsystems. Illustrations show where a converted part can sit, not a validated OEM assembly. No claim is made that any named robot maker uses any named material. Source context labels describe the cited evidence, not qualification. Humanoid context identifies a published robot function or requirement. Related technical evidence refers to material information or an analogous application; verify the cited scope. Design-dependent candidate requires a specific design review. Grade-specific data and assembly testing govern selection. Brand names are trademarks of their respective owners.