Thermal materials for humanoid robots
Gap pads, insulating TIMs and graphite spreaders for compute modules, drives and power electronics.

Who we've worked with
- University robotics teams
- Robotics R&D labs and think tanks
- World-leading industrial robot manufacturers
- ISO 9001:2015 certified organization
What does H-O make for humanoid robot thermal management?
Four parts H-O cuts for humanoid robot electronics: gap pads for the compute module, insulating pads for driver boards, graphite spreaders and duct seals. Send heat load, gap and pressure; we cut the pad to the layout.
Reviewed by H-O engineering·
Sources and how to read the evidence
Published application context: Henkel identifies thermal interfaces for humanoid robots and documents GAP PAD in an AGV control unit. The AGV case supports an adjacent application, not humanoid grade adoption. Electrical behavior is grade-specific; a thermal-pad brand does not establish insulation.
Pick the part. See the grade.
Select a part to see its job, the catalog grade we start with, and how strong the evidence is.








Compute-module interface (thermal transfer plate to chassis or cold plate)
Carries heat from the AI module’s factory thermal transfer plate into the robot’s chassis, heat sink or cold plate.
Start withJetson-class modules ship with a thermal transfer plate and factory TIM, so the pad you specify sits on top of that plate. Soft S-class pad conforms at low pressure, 3.0 W/m·K.
Higher heat-flux option
Same interface where the gap is thin and the heat flux is higher.
Start with5.0 W/m·K in the same soft family. A mid-range option, not the top of Bergquist’s range; thin bond lines matter more than the number.
Actuator driver electronics to housing
Insulated heat path from driver MOSFETs into the actuator housing.
Start withElectrically insulating, 1.8 W/m·K; about 50 psi clamp for rated performance.
Flat, clamped, non-isolated joints
Thin high-conductivity interface where both faces are flat and the joint is electrically isolated elsewhere.
Start withGraphite TIM needs roughly 700 kPa (100 psi) of clamp and flat surfaces; it is electrically conductive.
Lateral heat spreading
Spreads a hot spot sideways across a cover, shield or chassis panel.
Start withVery high in-plane conductivity; must be encapsulated or kept clear of live parts because graphite conducts electricity.
Thin dielectric layer in a TIM stack
Insulating film under a spreader or where a film thickness is specified.
Start withThermally conductive polyimide; bare film has high contact resistance, so pair it with a compliant layer.
Duct & air-dam seals
Stops cooling air from bypassing the fan path in an air-cooled torso.
Start withCellular silicone foam, UL 94 V-0, wide temperature range; die-cut strips with PSA.
Define the operating limits
Start with the constraints that govern thickness, material choice and assembly behavior. These nine inputs decide the grade.
Heat path
- Heat load per component
- Interface gap and flatness
- Mounting pressure at the cold plate or heat sink
Electrical isolation
- Interfaces that must insulate
- Graphite proximity to live parts
- Creepage around spreaders
Mechanical fit
- Component height variation
- Duct and air-dam geometry
- Service and rework access
Grade data sheets give properties under test conditions. Suitability at your interface is confirmed on the assembly.
Designed for assembly
Loose parts, adhesive-backed components or kiss-cut carriers to match your build sequence.
Illustrative part formats · positions vary by design

Thermal materials
Dielectric thermal pads & encapsulated graphite spreaders

Gaskets & cushioning
Silicone-foam static gaskets & PORON® kiss-cut pads

Shielding & harness protection
EMI gaskets, foil tape & UHMW / polyimide harness tapes
Review the technical details
Explore the zones on the robot, compare material families and inspect the supporting references.

01AI compute module interfaces (Jetson Thor / custom AI compute)
Humanoid context+
What to define first
Follow the compute module's thermal design guide for heat-transfer surface, interface thickness, mounting load and allowable temperature. Include flatness, assembly tolerance and serviceability.
Materials H-O converts
How H-O makes it
Die/flash cut, kit per module.
Sources
- NVIDIA Jetson Thor power modes and thermal-management requirementsdocs.nvidia.com
- NVIDIA: Jetson Thor platform and robotics ecosystemnvidianews.nvidia.com
- A Thor liquid-cooling block ships with a 60x60x1 mm thermal padconnecttech.com
- H-O TIM selection resourceh-oproducts.com
Watch-outs
A module reference design does not qualify one TIM for every robot integration. Confirm the selected material against the actual cooling assembly.
02Actuator driver electronics thermal path
Related technical evidence+
What to define first
Manage heat from drive electronics to the joint housing while meeting dielectric, clearance and mechanical requirements. Review stall and duty-cycle conditions.
Materials H-O converts
How H-O makes it
Die cutting, slitting or adhesive lamination to the specified part geometry; process confirmed during drawing review.
Sources
Watch-outs
Use the actuator page for the joint-specific stack-up and material considerations.
03Power electronics & DC-DC interfaces
Related technical evidence+
What to define first
Define converter losses, allowable component temperature and the path to chassis or heat sink. Check dielectric separation, magnetics insulation and assembly pressure.
Materials H-O converts
How H-O makes it
Die cutting, slitting or adhesive lamination to the specified part geometry; process confirmed during drawing review.
Sources
- LV conversion inside the packpatents.google.com
- H-O power-module TIM selection resourceh-oproducts.com
Watch-outs
Converted pads and films require a defined gap and mating surfaces; dispensed fillers use a different manufacturing process.
04Battery thermal interfaces
Related technical evidence+
What to define first
Coordinate the thermal interface with cell format, cooling surface, pressure limits and electrical isolation. Use pack-level thermal and safety testing to confirm suitability.
Materials H-O converts
How H-O makes it
Die cutting, slitting or adhesive lamination to the specified part geometry; process confirmed during drawing review.
Sources
- Figure: disclosed F.03 battery construction and safety testingfigure.ai
- BN-silicone dielectric padsh-oproducts.com
Watch-outs
Battery interfaces follow the pack architecture; a generic thermal-conductivity value is not a complete specification.
05Lateral heat spreading (graphite, conditional)
Related technical evidence+
What to define first
Select in-plane and through-plane behavior, thickness, bend limits and edge treatment for the heat path. Verify chassis grounding, creepage, clearance and the complete isolation scheme.
Materials H-O converts
How H-O makes it
Die/laser/waterjet cut, PET/PI encapsulation lamination.
Sources
- chinabizinsider.com
- H-O NeoGraf graphite pageh-oproducts.com
Watch-outs
Bare graphite and copper are conductive. Encapsulation must be designed and verified, including edges, cut-outs and assembly damage.
06Enclosure, duct & airflow sealing for conduction/forced-air paths
Related technical evidence+
What to define first
Define seal compression, airflow bypass, filter pressure drop and service access for a ducted design. Evaluate insulation against measured accessible-surface temperatures.
Materials H-O converts
How H-O makes it
Die cutting, lamination.
Sources
- A shared cooling duct for compute and batterypatents.google.com
- Boston Dynamics: published robot specificationsbostondynamics.com
- Silicone foam gasket propertiesrogerscorp.com
- H-O aerogel insulation pageh-oproducts.com
Watch-outs
Reticulated foam filters airflow; it is not a sealing gasket. Keep hot-zone insulation outside the intended cooling path. Sealed, fan-cooled and liquid-cooled assemblies require different interfaces.
Compare material options.
Compare application fit and limitations. Evidence labels describe the scope of the references; grade and assembly validation are still required.
Compare material families · use when, not when, confidence+
| Material family | Use when | Not when | Evidence context | H-O page |
|---|---|---|---|---|
| Dielectric thermal-interface pads (grade-specific) | Compliant thermal path with known pressure/thickness | Verify dielectric properties by grade; not every TIM or SIL PAD product is insulating | Humanoid context | View page → |
| Graphite spreaders: NeoGraf SpreaderShield | Electrical design allows a conductive spreader or provides PET/PI encapsulation | Conductive material: verify grounding, creepage, clearance and complete isolation scheme | Related technical evidence | View page → |
| BISCO HT-800 / HT-870 / BF-1000 silicone foam | Static gasket needs match closure force, thickness, temperature, environment | Not a cell-to-cell runaway barrier by default | Related technical evidence | View page → |
| Mica, ceramic and aerogel barriers; specialty silicone barriers (ProCell EV Firewall) | Battery safety design and abuse testing support the construction | Do not replace qualification with UL 94 claims | Related technical evidence | View page → |
| Copper / aluminum foil tapes and foil-film laminates | Shielding or grounding at the thermal assembly is required; not a TIM substitute | EMI foil-tape data does not qualify the tape as a heat spreader | Related technical evidence | View product → |
| Acrylic foam / transfer / LSE PSA | Substrate, surface energy, temperature, outgassing, removability validated | Validate adhesion on the actual substrate, finish and environment | Related technical evidence | View page → |
Technical sources and design context
Manufacturer references below verify material functions and product distinctions. They do not identify grades used by a humanoid OEM; candidate stacks require application qualification.
Related H-O pages
Thermal material questions.
How do engineers select thermal interface materials for humanoid robots?
+
Start with heat load, allowable temperatures, interface gap, surface flatness and contact pressure. Then check electrical isolation, assembly tolerance and service needs. H-O converts the selected pad, film or spreader construction to the required geometry.
Can graphite provide electrical insulation?
+
Bare graphite is electrically conductive. Before specification, verify chassis grounding, creepage, clearance and the complete isolation scheme. Any encapsulation must be designed and tested, including edges and cut-outs.
Do all humanoid robots use the same cooling approach?
+
No. Conduction, forced-air and liquid-cooled designs use different heat paths and interfaces. Follow the component supplier’s thermal requirements and qualify the complete robot assembly.
What does H-O Products supply for this application?
+
H-O converts films, foams, tapes and laminates into parts to drawing. Share the geometry, material requirements, quantity and inspection needs for review. The robot or subsystem designer remains responsible for material qualification and system performance.
Gap pad or graphite: which should I use on a humanoid's AI compute module?
+
Use a conformable gap pad such as Bergquist® Gap Pad TGP 3000 (or TGP 5000 for higher heat flux) between the module and your heat sink or cold plate. Jetson-class modules ship with a factory thermal transfer plate and TIM, so your pad sits on top of that plate, not on the bare SoC. Use NeoGraf® SpreaderShield™ graphite when you need to move heat sideways to a cooler area, and encapsulate it when it sits near live circuitry. Many designs use both.
Can H-O cut one thermal pad for several chips of different heights?
+
Yes. We die-cut multi-cavity pads and kit several thicknesses together so one carrier layout covers the SoC, VRM and memory. Send the component map with heights and allowable pressure.
Which thermal pads are also electrical insulators?
+
Bergquist® Sil-Pad TSP grades and Kapton® MT+ are designed as insulating thermal interfaces. Graphite and foil products are conductive. Verify dielectric strength by grade and thickness for your assembly.
Bring us the interface.
Send the drawing, operating conditions and expected quantities. We review material and converting options and come back with a quote.
- Heat load per component
- Allowable temperatures
- Interface gap and flatness
- Contact pressure
- Isolation requirement
- Cooling type (conduction
- Forced air or liquid)
- Annual quantity
Get a thermal interface quote
Send the drawing, operating conditions and quantities. We typically respond within one business day with a material recommendation, prototype lead time and converting options.
We've worked with university robotics teams, R&D labs and think tanks, and some of the world's leading industrial robot manufacturers.