Home › Blog › Aerospace, Defense & Space › Engine Bay & Nacelle Thermal Insulation › Nacelle insulation material selection
SOLIMIDE, Aerogel, Mica, or Silicone: Choosing Nacelle Insulation Materials
By the H-O Products applications engineering team · Updated June 2026 · ~9 min read
An engine bay is two problems wearing one name. The thermal problem keeps heat out of structure, wiring, and people, and is judged by conductivity. The fire problem keeps flame inside a designated zone, and is judged by entirely different methods. The families on the H-O nacelle insulation page split cleanly along that line, and this guide walks each one by the decision it wins, with methods named by designation and per-grade values kept on the maker TDS.
Request a quote for your project →
The nacelle is a stack, not a material
The single most expensive habit in propulsion-zone insulation is treating a bay as a one-material problem. A qualified nacelle stack is a layered system in which a thermal core, a fire-barrier ply, a surface facing, and a compliant seal each carry one job and carry the documented data for that job. The parent application page puts the rule plainly: separate the thermal job from the fire job before picking any material, because insulation keeps heat out of structure and a fire barrier keeps flame inside a zone, and one material rarely does both well.
This guide walks the families H-O converts for this zone by the decision each one wins, with methods named by designation: ASTM C177 for thermal conductivity, ASTM D1056 for compression-deflection and set on the sponge seals, UL 94 and ASTM E162 / E662 for flame, smoke, and toxicity behavior, AMS 3323 for the fluorosilicone family, and FAR 25.856 as the transport-category framing for thermal-acoustic insulation.
Per-grade values are the maker-TDS figures cited on the parent page.
The thermal core: mass against conductivity
Polyimide foam: the lightest way to fill a bay
Inlet-barrel and fan-cowl blanket cores want the lightest documented insulation available, which is open-cell polyimide foam: SOLIMIDE aerospace grades (the SOLIMIDE HT-340 grade for higher-temperature duty per its TDS) are among the lightest foams flying, and nacelle hardware pays for mass twice, once in fuel burn and once in the cowl's own structural sizing.
The flame, smoke, and toxicity data lives on the maker's TDS and is commonly evaluated against FAR 25.856(a). The foam is light because there is almost nothing there, so its facing and edge closure are part of the spec, not an option.
Aerogel blanket: thermal resistance in a fraction of the thickness
Bleed-air ducts and hot-line lagging want aerogel blanket, picked by line temperature. ArmaGel aerogel blanket (the warm-run default, conductivity per ASTM C177 and surface-burning data per ASTM E84 on the TDS) carries pre-cooler and warm bleed runs as the thin flexible default, and Pyrogel XTE, a family rated for service to 650 °C per the maker's data, takes the hottest sections nearest the engine.
The reason aerogel changed this job is thickness: it delivers a given thermal resistance in a fraction of conventional lagging depth, which is what keeps insulated ducts inside crowded cowls. Design thickness from the TDS conductivity values for your line.
The fire barrier: inorganic plies that do not insulate well
Fire barriers and insulators are not interchangeable, and the confusion is costly. Phlogopite mica sheet and ManniGlas glass-fiber paper (grades 1200, 1900, 1902, 2000) are inorganic barriers: superb against flame and radiant heat, modest as bulk insulation, and stable at temperatures past what any organic foam should see.
Mica holds the most severe radiant and flame locations; ManniGlas is the lighter inorganic ply that lets a layered stack add fire and thermal margin without mica thickness everywhere. Where a heat-shield foam suits the stack, the BISCO RF-120 heat-shield foam from the specialty silicone foam family was developed for radiant-shield duty, with flame and smoke data on the Rogers TDS.
Where a wall needs both steady-state insulation and a fire rating, the two-layer construction is normal, and H-O laminates barrier and insulation as one converted part. Ply order in a barrier stack is part of the qualified design.
The seals: chemistry before firmness
Access-panel and equipment-cover gaskets in a propulsion bay sort on a single question that comes before firmness: what fluid can reach the seal.
Dry hot-zone gaskets stay on closed-cell silicone foam (BISCO HT and BF series, with the HT-800 medium grade as a representative firmness) and kSil V-0 sponge (a UL 94 V-0 listed silicone sponge per its TDS): silicone-class temperature capability and compression-set behavior per ASTM D1056 that survive daily cycling.
Where fuel, oil, or hydraulic mist can reach the joint, the answer moves to fluorosilicone sponge (the AMS 3323 family), whose fluid resistance relative to standard silicone is the reason it exists. The chemistry call comes before the firmness call.
The facing: insulation failures start at the surface
Most propulsion-zone insulation failures in service start at the surface, not in the core: high-velocity bay airflow erodes an unfaced blanket edge, a harness chafes through a facing, a boot heel crushes a soft core during inspection.
The protection layer is therefore part of the insulation spec. PTFE-coated fiberglass is the working facing family: glass-cloth strength and temperature capability with a low-friction surface that sheds fluids and survives contact, supplied as facings laminated to blanket cores, slit-width wrap for lines, and die-cut rub strips at known chafe points.
Erosion starts at unsealed edges and seams rather than face sheets, so the closure detail matters as much as the facing material.
Propulsion-Zone Families by the Job They Win
| Family | Job in the stack | Fluid role | Temperature position (per TDS) | Where it lives |
|---|---|---|---|---|
| SOLIMIDE polyimide foam | Thermal core | Protect from mist | Inlet / cowl regime per grade | Ultra-light blanket cores, APU walls, infills |
| ArmaGel / Pyrogel XTE | Duct lagging | Faced where exposed | Pyrogel XTE to 650 °C per maker data | Warm to hottest bleed and pre-cooler runs |
| Mica / ManniGlas | Fire barrier | Inorganic, fluid-stable | Inorganic high-temp stability | Firewall plies, heat-shield stacks |
| BISCO HT / BF / kSil V-0 | Dry-zone seal | Silicone economics | Silicone window per ASTM D1056 | Access doors, covers, penetrations (dry) |
| Fluorosilicone sponge | Wet-zone seal | Fuel / oil mist | Per AMS 3323 grade | Mist-path and drain-path gaskets |
| PTFE-coated fiberglass | Facing / wrap | Sheds fluids | Per TDS series | Erosion and handling protection |
Illustrative and relative only; confirm each grade on its current technical data sheet. Thermal cores compared per ASTM C177; sponge seals per ASTM D1056; fire-zone qualification per ISO 2685 / AC 20-135 campaigns owned by the integrator.
Two rules that sort the page
First, the temperature ceiling comes from the TDS, not the family name: polyimide foam covers the inlet and cowl regime, aerogel blanket covers warm to hot duct runs by grade, and the inorganic plies hold the locations where radiant and flame exposure exceed what any organic foam should see. Second, name the part's fire role on the drawing, because the governing framing follows the role: FAR 25.856 frames thermal-acoustic insulation, ISO 2685 and AC 20-135 frame fire-zone hardware, and FAR 25.853 frames compartment interiors.
A material should carry only the data its TDS actually shows.
How H-O Products helps
H-O Products is a precision die-cut converter, not a raw-material producer. We take polyimide foam, aerogel blanket, mica, glass-fiber paper, silicone and fluorosilicone sponge, and PTFE-coated fiberglass stock from the material manufacturers and die-cut, knife-cut, kiss-cut on liner, slit, and laminate it to your drawing, with material traceability and lot-code TDS records under our ISO 9001:2015 certified quality management system in Winsted, Connecticut.
We recommend a family and grade direction from your zone temperature profile, fire role, mass and thickness budget, fluid exposure, and attachment method, and grade-level values are confirmed against the manufacturer's current TDS. Fire-zone qualification, FAR 25.856 compliance findings, and airworthiness sign-off stay with the airframer and the propulsion integrator.
Frequently asked questions
What insulation goes inside a jet engine nacelle?
Layered stacks, not a single material. The thermal core in inlet and fan-cowl bays is typically SOLIMIDE polyimide foam, an ultra-light foam whose flame, smoke, and toxicity data is documented on the maker's TDS and commonly evaluated against the FAR 25.856(a) flame-propagation requirement. Around it sit the supporting layers: mica or ManniGlas barrier plies where the fire strategy calls for them, a PTFE-coated fiberglass facing against erosion and handling, and silicone-foam edge gaskets where the blanket meets structure.
Is thermal insulation the same as a fire barrier?
No, and treating them as interchangeable is the most expensive confusion in this zone. Insulation such as polyimide foam and aerogel blanket limits heat transfer to structure; a fire barrier such as mica sheet or glass-fiber paper resists flame and radiant exposure as part of a containment strategy tested per ISO 2685 and AC 20-135 campaigns. Qualified nacelle stacks layer the two jobs, and a drawing should name which job each ply carries.
When does a seal need fluorosilicone instead of silicone?
When the seal lives in the fuel, oil, or hydraulic mist path. Standard silicone elastomers are a poor long-term match for those exposures: they swell and soften where mist and drips collect. Fluorosilicone sponge, the AMS 3323 family, holds its properties in exactly those locations, which is why APU access doors and drain-path seals move to it while dry-side gaskets stay on standard silicone economics. Classify each location by what can reach it and confirm against the program's fluid specification.
Why use aerogel blanket instead of conventional duct lagging?
Thickness. Aerogel blankets deliver a given thermal resistance in a fraction of conventional lagging depth, per the ASTM C177 conductivity values on their TDS, and propulsion bays are exactly where that matters: crowded routing, tight cowls, and personnel touch-protection surface-temperature targets. The trade is mechanical delicacy, which the facing layer answers. Where thickness is free, conventional lagging can win on cost; in a nacelle, thickness is never free.
Does H-O certify parts for fire zones or hold flight qualification?
No, and a converter that claims to should worry you. Fire-zone qualification under ISO 2685 and AC 20-135 campaigns, insulation compliance findings under FAR 25.856, and airworthiness sign-off belong to the airframer, the propulsion integrator, and their test houses. H-O's role is bounded: convert the documented materials to the qualified drawing, repeatably, with material traceability and lot-code TDS records that support your certification file.
Get a nacelle insulation recommendation
Tell us the zone temperature profile, the fire role of each part, the mass and thickness budget, the fluid exposure at the seals, and the attachment method, and we will recommend a family and grade direction and quote die-cut parts to your drawing.
Samples typically ship in 3 to 5 business days for common die-cut configurations on materials we keep on hand; standard production runs about two weeks after drawing approval; expedited service is available. MOQ varies by material and part.
Family-owned in Winsted, Connecticut since 1971 · ISO 9001:2015 certified · OEMs worldwide send us a drawing — and get back their part.
Related reading
Request a quote for your engine-bay & nacelle thermal insulation part
Send H-O your drawing or describe the part—engineering reviews every RFQ and converts samples on your geometry.
Last updated · Reviewed by H-O Products engineering (ISO 9001:2015 certified converter, Winsted, CT).
References
- FAR 25.856(a) and (b) (thermal-acoustic insulation flame propagation and burnthrough, transport-category framing); FAR 25.853 (compartment-interior flammability).
- ISO 2685 and AC 20-135 (fire-resistance test framing for designated-fire-zone hardware, owned by the integrator).
- ASTM C177 (steady-state thermal conductivity, the blanket and core method); ASTM E84 (surface burning, cited on the aerogel TDS).
- ASTM D1056 (compression-deflection and compression set for sponge seals); UL 94 and ASTM E162 / E662 (flame, smoke, and toxicity data, per grade); AMS 3323 (fluorosilicone sponge).
- Manufacturer technical data sheets for the polyimide foam, aerogel blanket, mica, glass-fiber paper, silicone and fluorosilicone sponge, and PTFE-coated fiberglass grades named on the parent application page.
This article summarizes insulation material-selection principles for engine bays and nacelles using the families and published test methods cited on the parent application page. Comparisons are qualitative; per-grade values quoted are maker-TDS figures and must be confirmed on the manufacturer's current technical data sheet at your thickness, temperature, and installed condition. Standards (FAR, AMS, ISO, ASTM, UL) are cited by designation for context, not as a claim of qualification.
H-O is a precision die-cut converter, not a raw-material producer, and does not perform thermal design, certify materials, or hold flight or fire-zone qualification; those belong to the airframer, the propulsion integrator, and their test houses.