Home › Blog › Wound Care & NPWT › Selecting the NPWT material stack
NPWT Material Stack by Design: Selecting Interface Foam, Drape and Adhesive
By the H-O Products applications engineering team · Updated June 2026 · ~8 min read
An NPWT material stack is a foam, a film and an adhesive that work together while being selected on entirely different property axes: the interface foam on porosity and open-cell structure, the drape film on barrier and moisture-vapor transmission, and the skin-contact border on peel and a material-level ISO 10993-10 evaluation. Treating them as one decision is where stacks go wrong.
This guide explains the three axes, shows how to coordinate the selections so the materials fit together, and reads each off its own data sheet, with everything kept strictly at the material level and no claim about treating or healing.
Three materials, three independent property sets
An NPWT material stack is a foam, a film and an adhesive that have to work together while being selected on entirely different property axes. Treating them as one decision is where stacks go wrong; selecting each on its own axis is how a buildable stack comes together. Every property below is a material property read off the maker's data sheet, and none of it is a statement about therapy or outcomes.
- The interface foam axis: porosity and structure. Pore size (pores per inch) and the open-cell, through-porous structure decide how readily fluid and air move through the foam. Characterized per ASTM D3574; a finer or coarser pore range is a grade choice.
- The drape axis: barrier and moisture-vapor. The film must be a closed barrier that supports the seal yet manage moisture-vapor transmission so the construction behaves over the wear window. Characterized per ASTM E96.
- The adhesive axis: wear and material-level evaluation. The skin-contact border must hold for the wear window, release cleanly, and carry an ISO 10993-10 material-level evaluation. Peel is characterized per ASTM D3330.
How do you select the three materials so they fit together?
Start with the foam, because its role is the most distinctive: it must be open and permeable. Choose a reticulated open-cell polyurethane and state the pore range; a coated grade is an option where a different surface or finer structure is wanted. Then select the drape as the opposite kind of material, a closed, conformable film whose barrier holds the seal while its moisture-vapor transmission keeps the construction stable over the intended wear time.
Finally select the skin-contact border to hold the drape for that wear window with a clean release, reading its peel and confirming the ISO 10993-10 designation on the grade. The three selections are independent in their properties but coordinated in the build: the foam is permeable, the drape is sealing, and the adhesive holds the assembly to skin. The numbers live on three different data sheets, and the finished device defines how the assembly is used.
Reading the three data sheets: what each property is and is not
| Material | Property to read | What it is not |
|---|---|---|
| Interface foam | Pore range and open-cell structure (ASTM D3574) | A therapy parameter; it is a permeability property of the foam |
| Interface foam | Force-deflection and recovery | A statement about the wound; it is how the foam compresses |
| Drape film | Barrier and moisture-vapor transmission (ASTM E96) | A guarantee of seal; the seal is a finished-construction property |
| Skin adhesive | Peel (ASTM D3330) and backing | A wear time on a person; that is a finished-device matter |
| Skin adhesive | ISO 10993-10 designation | A finished-device biocompatibility clearance, which the device maker owns |
A worked reading: coordinating the stack
Suppose the device calls for a moderate-porosity interface foam, a conformable drape with a controlled moisture-vapor transmission, and a skin border for a multi-day wear window. The foam is selected as a reticulated open-cell polyurethane with the stated pore range and confirmed on its data sheet. The drape is selected as a closed film whose moisture-vapor transmission is read against ASTM E96 so it neither traps nor dries the construction unpredictably over the window.
The skin border is selected for a peel that holds the drape and releases cleanly, on a backing whose breathability suits the longer wear, with the ISO 10993-10 designation confirmed on the grade. Three data sheets, three coordinated material choices, and one device that the maker defines and assesses. H-O die-cuts each material to the geometry and kits the set.
NPWT Stack: Which Property to Read for Each Material
For the interface foam, read the pore range and open-cell structure (ASTM D3574) and state pores per inch; a reticulated open-cell polyurethane fits. Confirm the grade on the data sheet. This is a material property, not a therapy parameter.
Illustrative only; confirm against current material data and a drawing review. This selector returns which property to read and a material family direction, not a grade, a pore size or any clinical or therapeutic claim, and it makes no claim that any material treats or heals. Porosity (ASTM D3574), moisture-vapor transmission (ASTM E96), peel (ASTM D3330) and the ISO 10993-10 designation are read on the makers' current data sheets, and the finished device and its use belong to the device maker.
Design and converting considerations
- Select foam-first. The interface foam's permeability is the most distinctive requirement; state the pore range and confirm the open-cell grade.
- Make the drape the opposite material. A closed, conformable film whose moisture-vapor transmission is read against ASTM E96; the seal belongs to the finished construction.
- Coordinate the adhesive to the wear window. Read peel and choose the backing for the wear time; confirm the ISO 10993-10 designation on the grade.
- Keep the three on three data sheets. They are independent property sets; do not specify one number for the stack.
- Process fit. Foam, drape and adhesive are die-cut, laminated and kitted to the device geometry on release liners.
Common material mismatches
| Mismatch | Root cause | Reading correction |
|---|---|---|
| Stack specified as one material | Foam, drape and adhesive treated as a single decision | Select each on its own axis: porosity, barrier, peel |
| Interface foam too closed | Pore range not stated, a low-porosity grade supplied | State pores per inch; read the open-cell structure per ASTM D3574 |
| Drape behaves unpredictably over the window | Moisture-vapor transmission not read | Read MVTR per ASTM E96 and select the film for a controlled value |
| Border lifts on a multi-day window | Adhesive and backing mismatched to the wear time | Reselect for a breathable backing; read peel per ASTM D3330 |
| Designation assumed on the adhesive | ISO 10993-10 not confirmed on the grade | Confirm the ISO 10993-10 designation on the specific data sheet |
How H-O Products helps
H-O Products is a precision die-cut converter serving medical and clean-component programs. For a wound-care or NPWT device we die-cut the interface foam, the drape film and the skin-contact border to your geometry, and help you coordinate the three selections so each material is read on its own data sheet. As an ISO 9001:2015 certified organization we name a foam, film or adhesive family only where it is catalog-verified, and we defer every grade-specific number to the manufacturer's current technical data sheet.
We do not produce the raw materials and we do not make the finished device; the device, its indications and its clinical performance belong to you, and we make no claim that any material treats or heals a wound.
Coordinating an NPWT foam, drape and adhesive stack?
Tell us the pore range, the drape barrier and the wear window, and any material-level documentation you need. We will help you read the three data sheets, recommend a family direction for each material, and die-cut the set on your geometry.
Samples typically ship in 3 to 5 business days for common die-cut configurations; standard production runs about two weeks; special orders are quoted to the job.
Family-owned in Winsted, Connecticut since 1971 · ISO 9001:2015 certified · OEMs worldwide send us a drawing — and get back their part.
Related reading
IndustryMedical & clean components overview (industry hub)Read →
Frequently asked questions
How do the foam, drape and adhesive in an NPWT stack relate?
They are three materials selected on three different property axes and coordinated in the build. The interface foam is an open, through-porous reticulated polyurethane selected on pore range and open-cell structure. The drape is the opposite, a closed conformable film selected on barrier and moisture-vapor transmission. The skin-contact border holds the drape for the wear window, selected on peel and a material-level ISO 10993-10 evaluation.
Each lives on its own data sheet. H-O die-cuts each to the geometry; the finished device defines how the assembly is used.
What is moisture-vapor transmission and why read it for a drape?
Moisture-vapor transmission, characterized per ASTM E96, describes how readily a film passes water vapor. For an NPWT drape it is read so the closed film holds the seal while managing moisture over the wear window, neither trapping nor drying the construction unpredictably. It is a material property of the film, read on the maker's data sheet. It is not a guarantee of seal, which is a finished-construction property, and it is not a clinical claim.
Is any of this a wound-healing or therapy claim?
No. This guide describes how to select foam, drape and adhesive materials by their mechanical and material-level properties. It makes no claim that any material treats, heals, manages or improves a wound or any condition. Wound healing, therapy, indications and clinical outcomes belong to the finished device and its maker. H-O Products is a die-cut converter and an ISO 9001:2015 certified organization; material-level designations such as ISO 10993 describe the material, not the device.
Request a quote for your NPWT material stack
Send H-O your stack and geometry—engineering helps you read the three data sheets, recommends a family per material, and die-cuts the set on your geometry.
Last updated · Reviewed by H-O Products engineering (ISO 9001:2015 certified converter, Winsted, CT).
References
- ASTM D3574, Standard Test Methods for Flexible Cellular Materials: Slab, Bonded, and Molded Urethane Foams. ASTM International.
- ASTM E96, Standard Test Methods for Water Vapor Transmission of Materials. ASTM International.
- ASTM D3330, Standard Test Method for Peel Adhesion of Pressure-Sensitive Tape. ASTM International.
- ISO 10993-10, Biological Evaluation of Medical Devices, Part 10: Tests for Skin Sensitization. International Organization for Standardization (material-level designation).
- ISO 10993-1, Biological Evaluation of Medical Devices, Part 1: Evaluation and Testing Within a Risk Management Process. International Organization for Standardization (material-level designation).
- Manufacturer technical data sheets for the named material families; porosity, moisture-vapor, peel and material-level designations are confirmed on the makers' current TDS.
This article describes material families H-O Products converts for negative pressure wound therapy (NPWT) and wound-care devices and cites published standards by designation (ASTM D3574 for urethane cellular materials, ISO 10993 and USP Class VI as material-level designations, ASTM E96 for water-vapor transmission, ASTM D3330 for peel adhesion). It describes foam, drape and adhesive materials only.
It makes no patient, clinical or therapeutic claim, and no claim that any material treats, heals, manages or improves a wound or any condition; wound healing, therapy and clinical outcomes are the responsibility of the finished device and its maker, not of any material described here.
The material maker characterizes and documents a grade on its current technical data sheet; the device maker owns the finished device, its indications, its biocompatibility assessment and its regulatory file. H-O Products is a precision die-cut converter, not a raw-material producer and not a medical-device manufacturer; this is not, and does not imply, an ISO 13485 certification, an FDA device registration, a cleanroom certification or a biocompatibility certification.
The only certification claimed is ISO 9001:2015, which governs the converting process. Grade-specific values are confirmed against the manufacturer's current technical data sheet and an engineering drawing review. All parts are custom manufactured to order and minimum production run quantities apply.