Orbital Data Centers: Six Materials Questions to Settle Before the Compute Node Flies

Why radiator area turns every thermal interface into a design decision, which gap pads, graphite spreaders, cushions, seals, films and foams carry ASTM E595 outgassing data, and what thermal cycling, launch and EMI do to the shortlist.

Communications satellite with twin solar arrays in low Earth orbit above North America at night, city lights visible below

Between November 2025 and February 2026 the idea of running servers in orbit went from pitch decks to hardware and paperwork. Starcloud flew an Nvidia H100 on a small satellite and, by December, had run Google's open Gemma model and trained a small language model on it in orbit. Google published its Project Suncatcher design study, with proton-beam radiation results for its TPUs and a plan to fly two prototype satellites with Planet by early 2027. Axiom Space's first two free-flying data-center nodes launched in January on Kepler's optical relay network. In February the FCC accepted for filing a SpaceX application for up to one million satellites at 500 to 2,000 km, described as orbital data centers. Whatever the economics turn out to be, every one of those boxes is a satellite first and a server second. The silicon is the same silicon that runs in a terrestrial rack, but the air that carried its heat away is gone, the elastomers and foams around it are sitting in vacuum, and the whole assembly has to survive a launch nothing in a data hall was designed for. This article is about the converted materials inside such a node, the gap pads, insulators, cushions, gaskets, films and foams, and the six questions a thermal or mechanical engineer should settle about them before the drawing goes out.

Short answer. In orbit the only exit for waste heat is a radiator, and radiator area is set by the temperature at which heat reaches it. Every kelvin dropped across the conduction path from die to radiator, including the thermal interface materials, is paid for in radiator area and launch mass, so the interface stack deserves the same attention as the chip. Everything polymeric in the box must then clear the outgassing screen (ASTM E595: TML ≤1.0%, CVCM ≤0.10%), survive thermal cycling and launch vibration, keep the RF in and out, and be insulated where heat must not go. H-O converts screened grades for each of those jobs, from E595-reported PORON and platinum-cured silicone to polyimide films and foams and Bergquist thermal pads, into parts to your drawing; the screening and the flight qualification stay with the material maker and your program.

Request a quote →

Why a GPU in orbit is a materials problem before it is a software problem

On the ground a 40 kW rack rejects its heat into air or water and the building deals with the rest. In orbit there is no convection. Heat leaves a spacecraft only by radiation, at a rate set by the Stefan–Boltzmann law: proportional to radiator area and to the fourth power of the radiator's absolute temperature. A perfect emitter at 20 °C radiates about 420 W per square metre of surface; a real radiator with finite emissivity, which also absorbs sunlight (1,361 W/m² at Earth's distance), Earth-shine and heat from its own structure, delivers less. IEEE Spectrum's June 2026 analysis put the numbers on a single 700 W accelerator: just under 3 m² of radiator if the heat arrives at 20 °C, about 1.4 m² at 60 °C, about 1 m² at 85 °C, and roughly 40% more after five years as the radiator coating degrades. A 40 kW rack-equivalent came out near 80 m². A system study from NASA's Jet Propulsion Laboratory published in April 2026 sized the radiator for a 1 MW orbital cluster at about 2,500 m² and the solar array at about 5,640 m², with photovoltaics, storage and radiators alone weighing about 29 kg per kilowatt; the Spectrum piece estimated radiators and arrays at 65 to 70% of satellite mass.

Two things follow for the materials. First, the temperature at which heat reaches the radiator is the biggest single lever in the design, and it is set by the chain of conduction between the die and the radiator face: package lid, interface material, cold plate or heat pipe, strap, structure, radiator skin. Each joint drops some temperature, and every degree dropped there either raises the junction temperature or grows the radiator. Second, there is a reason Google's Suncatcher write-up lists thermal management among its open engineering challenges. The problem is not exotic; it is relentless, and it runs through ordinary converted parts.

Question 1: The conduction path, and where every kelvin goes

In a terrestrial server the gap pad under a voltage regulator or a memory package is a packaging convenience. In orbit it is part of the radiator sizing. The arithmetic is short: the temperature drop across a pad is its thermal impedance multiplied by the heat flux through it. Bergquist GAP PAD TGP 6000ULM, a 6.0 W/m·K ultra-low-modulus pad, lists 0.34 °C·in²/W at 0.040 in and 10% deflection. At a heat flux of 10 W/in² that is a 3.4 °C drop; at 50 W/in² it is 17 °C. TGP 3500ULM (3.5 W/m·K, 70 Shore 000) lists 0.5 °C·in²/W at the same condition, and TGP 3000 (3.0 W/m·K, fiberglass-reinforced, dielectric breakdown above 3,000 VAC) is the soft, fiberglass-reinforced member for fixed-standoff and clip mounting. The datasheet impedance falls with deflection (6000ULM reaches 0.26 °C·in²/W at 30%), which is why the clamp design and the stack-up tolerance matter as much as the pad grade: the thinnest pad that still fills the gap at the coldest, loosest condition is the right one.

Liquid cold plate bolted over a processor on a server board, with coolant hoses and bundled cabling around it
Where the chain begins. A cold plate clamped over a processor. Everything between this surface and the radiator face, the interface material under the plate, the fluid or heat-pipe path, the structural joints, drops temperature, and in orbit every degree of that drop is bought back with radiator area.

Where the interface must also insulate, a transistor tab to a chassis or a busbar to a cold plate, the Bergquist SIL PAD TSP K1300 is the kind of part that does both jobs: a 0.15 mm Kapton-reinforced silicone insulator at 1.3 W/m·K with 6,000 VAC minimum breakdown, rated −60 to +180 °C. It is also one of the few interface materials on our pages with vacuum weight-loss data, 0.36% TML and 0.09% VCM to NASA SP-R-0022A, the NASA specification that preceded today's ASTM E595 screen.

Then there is the silicone question. Most gap pads are silicone, and silicone near optics, laser-link apertures or RF connectors is a contamination question before it is a thermal one. Henkel's silicone-free grades exist for exactly that reason: GAP PAD TGP 2200SF (2.0 W/m·K, electrically isolating, −60 to +125 °C) and GAP PAD TGP 40000SF (an oriented-filler pad at 40 W/m·K, −40 to +150 °C, not electrically insulating). Silicone-free is not the same as screened. Our product pages do not carry ASTM E595 results for the GAP PAD grades, so if a pad sits inside a contamination-controlled volume, the E595 report for that specific grade has to be requested from the maker before it goes on the drawing. The companion article on TIM pump-out and breathing joints under altitude cycling covers what repeated thermal cycling does to a pad over time; in vacuum the cycling is still there and the air that would re-wet the joint is not.

Between the pad and the radiator there is usually a spreading job as well: a hot spot the size of a die has to become a warm area the size of a cold plate or a conduction strap before the heat can be carried away, and in-plane conductivity does that work. That is where flexible graphite earns its place on a satellite. SpreaderShield SS400 natural graphite sheet carries 400 ±100 W/m·K in-plane against 2.2 W/m·K through-plane, in five gauges from 0.051 to 0.94 mm at a density of 1.75 g/cm³, roughly a fifth of copper's; its page lists die-cut and laminated heat spreaders for satellites among its uses, rates the uncoated sheet from −250 °C upward in vacuum, and rates the standard PET and adhesive coatings to −30 to +140 °C long-term, which is the number that governs a coated part. At the interface itself, eGRAF HiTherm HT-C3200 is a 200 µm compressible graphite TIM with 7 W/m·K through-plane at 700 kPa and a thermal impedance of 0.18 K·cm²/W at that pressure, about 0.03 °C·in²/W, an order of magnitude below a gap pad, at the cost of needing a flat, firmly clamped joint: it takes up about 125 µm of flatness variation where a gap pad takes up millimetres. Neither NeoGraf page shows an ASTM E595 result, so graphite joins the ask-for-the-data column in a contamination-controlled volume, and it is electrically conductive (HT-C3200 lists 19,000 S/cm in-plane), which decides where it can and cannot sit.

Roll of die-cut SpreaderShield flexible graphite heat-spreader parts on kraft release liner, converted by H-O Products
Spreading before conducting. Die-cut SpreaderShield flexible graphite heat spreaders on a kraft liner. Several hundred W/m·K in-plane turns a die-sized hot spot into a cold-plate-sized warm area at about a fifth of copper's density; on a coated part it is the PET and adhesive, not the graphite, that set the service temperature.

Question 2: Outgassing. Screen the bill of materials before you compare properties

ASTM E595 holds a sample for 24 hours at 125 °C under vacuum and weighs what left it (total mass loss, TML) and what condensed on a 25 °C collector plate (collected volatile condensable material, CVCM). NASA's screening limits, adopted in NASA-STD-6016, are TML ≤1.0% and CVCM ≤0.10%, and CVCM is the one that fogs a star tracker or a laser-link optic. We have written a full guide to reading those two numbers on a datasheet; what matters for a compute node is which of the ordinary materials inside it have results at all. On our product pages the list is short: SSP2390-60D platinum-cured solid silicone (0.05% TML, 0.004% CVCM, ASTM E595-15); Low Outgassing Silicone Sheeting (≤1.00% and ≤0.10% across its 40, 50, 60 and 70 Shore A grades); PORON 4701-50 (0.6 to 0.8% TML, 0.04 to 0.06% CVCM by density) and PORON 4701-60 (0.6 to 0.7% and 0.02 to 0.05%); PORON AquaPro 37 (0.58% and 0.02%) and AquaPro 4701-41 (0.84 to 1.0% and 0.04 to 0.06%); SOLIMIDE AC-550H and its AC-530 and AC-550 siblings (below 1.0% and 0.1%); the AeroZero AZ-TPS 102, 103 and 104 polyimide-aerogel films (below 1% and 0.1%); and the SIL PAD TSP K1300 above.

The same pages show why "it is the material we always use" is not an argument. BISCO HT-800 cellular silicone, a staple of enclosure gaskets, reports 0.98% TML and 0.25% CVCM: inside the mass-loss limit, two and a half times over the condensables limit. HT-820 and HT-840 report 2.11% and 2.08% TML with 0.63% and 0.57% CVCM. PORON 4790-92 slow-rebound foam reports 1.63 to 1.73% TML and 0.14 to 0.29% CVCM; PORON 4701-30 sits at the limits (1.0 to 1.3% TML, 0.1 to 0.2% CVCM) and exceeds them in its 400 kg/m³ grade; PORON 4701-40V0 reports 1.07% TML with no CVCM published. The EPDM sheet grades state plainly that the manufacturer has published no E595 data. The conductive silicones 502-40-V0 and 502-60-V0 list E595 testing, with and without their conductive adhesive, as available on request. A blank on a datasheet is not a pass.

Job in the nodeGrade (links to specifications)TMLCVCMAs shown on the manufacturer datasheet
Thermal interface, electrically insulatingSIL PAD TSP K13000.36%0.09% (VCM)NASA SP-R-0022A; 1.3 W/m·K; 6,000 VAC min.; −60 to +180 °C
Seals and gaskets, solid siliconeSSP2390-60D (the 50D page quotes the 60D test)0.05%0.004%ASTM E595-15, third-party report; platinum cure; WVR 0.04%
Seals and pads, solid siliconeLow Outgassing Silicone Sheeting, 40–70 Shore A≤1.00%≤0.10%Post-cured; 0.005 to 0.500 in; −85 to +525 °F intermittent
Cushions, bumpers, card-guide padsPORON 4701-600.6 / 0.7 / 0.7%0.05 / 0.02 / 0.03%At 240 / 320 / 400 kg/m³; ASTM E595-93; 90 °C continuous, 121 °C intermittent
Cushions and low-load gasketsPORON 4701-500.6 / 0.8%0.04 / 0.05 / 0.06%At 240 / 320 (/ 480) kg/m³; ASTM E595-93
Soft sealing foamPORON AquaPro 370.58%0.02%ASTM E595; WVR 0.09%
Lightweight insulation and acoustic fillSOLIMIDE AC-550H (also AC-530, AC-550, polyimide foam)<1.0%<0.1%ASTM E595; 8 kg/m³; 0.043 W/m·K at 24 °C; 200 °C continuous
Thin conformal thermal barrierAeroZero AZ-TPS 102 / 103 / 104<1%<0.1%ASTM E595; acrylic PSA; 0.037 to 0.049 W/m·K; 190.5 to 292.1 µm total
Reported, and outside the limits: BISCO HT-800 (0.98% / 0.25%), HT-820 (2.11% / 0.63%), HT-840 (2.08% / 0.57%), PORON 4790-92 (1.63–1.73% / 0.14–0.29%). Not reported on our pages: GAP PAD TGP family, flexible graphite (SpreaderShield, eGRAF HiTherm), the silver-filled silicone and fluorosilicone shielding elastomers (MIL-DTL-83528 Types A, B and D), polyimide films, aerogel blankets, GORE vents; ask for the maker's grade-specific data before specifying any of these inside a contamination-controlled volume.
Rule for the BOM. List every polymer, adhesive and liner in the node, mark which volumes are contamination-controlled, and strike anything in those volumes without a published or requested E595 result before you compare conductivities and compression curves. The thermal comparison is only worth doing among grades that can fly.
Cleanroom technician pushing an anti-static trolley loaded with cubesat magnetorquer rods wrapped in amber polyimide
Everything on the trolley is on the list. Flight hardware moving through a cleanroom on an anti-static trolley. The tape, the wrap, the cushioning it sits on and the bag it ships in are all polymers, and all of them belong on the outgassing bill of materials before any of them is compared on performance.

Question 3: Thermal cycling between a sunlit face and a shaded one

A low-Earth-orbit satellite passes from sunlight into Earth's shadow roughly every 90 minutes. NASA's thermal engineers at Johnson Space Center quote the uncontrolled skin of the International Space Station at about +121 °C (250 °F) in sunlight and −157 °C (−250 °F) in shadow. A dawn–dusk sun-synchronous orbit like the one modelled in Google's Suncatcher study is chosen partly to avoid most eclipses, but the radiator and anything thermally tied to it still live far from room temperature, and the electronics bay stays in its band only because the thermal design holds it there. For materials that means three checks: the service range on the datasheet, how the part behaves at the cold end (embrittlement, loss of compliance, loss of adhesive tack), and how its expansion compares with the aluminium or composite it is bonded between over thousands of cycles.

The ranges on our pages span a great deal. Kapton HN polyimide film has been used from −269 to +400 °C and has no melting point, which is why it is the default multilayer-insulation layer and wrap. SSP2575 low-outgas silicone keeps its low-temperature flexibility to −116 °C (−177 °F), the grade to ask about for a seal that must stay elastic in a cold compartment (its datasheet calls it a low-outgas formulation but publishes no E595 values, so request test data before specifying it). The Bergquist GAP PAD TGP 3000, 3500ULM and 6000ULM are rated −60 to +200 °C; the silicone-free TGP 2200SF only to +125 °C and TGP 40000SF from −40 to +150 °C. PORON 4701-60 lists an embrittlement temperature of −40 °C and 4701-30 of −51 °C, with 90 °C continuous and 121 °C intermittent use; they belong inside the controlled bay, not against the radiator. BISCO EC-2130 conductive silicone is rated −79.6 to 392 °F (about −62 to +200 °C). The rule is to match the datasheet range to the location in the spacecraft, not to the spacecraft as a whole, and to read the cold-end line as carefully as the maximum.

Satellite with a gold multilayer-insulation-wrapped instrument barrel and deployed solar arrays against the dark of space
Two temperature worlds on one spacecraft. The gold multilayer insulation on this instrument barrel sees the full swing between sunlight and shadow; the electronics behind it are held in a narrow band by the thermal design. The datasheet range a material needs depends on which side of that blanket it sits.

Question 4: Launch. Loads for eight minutes, vacuum for five years

Launch imposes random vibration, acoustic loading and pyrotechnic shock that no rack ever sees. The isolation and cushioning materials that handle those loads on aircraft (our article on isolator resonance, natural frequency and transmissibility covers the mechanics) are the same ones here, with the outgassing screen applied on top. That is why PORON 4701-50 and 4701-60 appear twice in this article: they are firm microcellular urethanes with low compression set (4701-60: 4.7 to 7.9% maximum at 70 °C across its densities; 4701-50: 10% maximum), with compression force deflection at 25% from 69 kPa (10 psi) in the softest 4701-50 grade to 783 kPa (114 psi) in the densest 4701-60 (each by the method on its own datasheet), and they report E595 results. The cellular silicone foam that would be the reflex choice for a board-edge cushion on the ground, BISCO HT-800, does not clear the CVCM limit. Board-level pads, card-guide cushions, battery cell spacers and bumpers are die-cut from the PORON grades; perimeter seals that must hold compression for years in vacuum are cut from SSP2390-60D or Low Outgassing Silicone Sheeting.

Ascent also empties the box. A sealed enclosure with one atmosphere inside it on the pad has a full bar of pressure trying to get out by the time it reaches orbit, and multilayer blankets balloon if their vent path was an afterthought (the spacecraft materials page walks through that failure case). Every enclosed volume needs a deliberate vent, and during integration the vent is also the particulate barrier. GORE protective vents in adhesive, snap-in and screw-in series use ePTFE membranes that pass gas and stop particles and liquid water on telecom, industrial and outdoor electronics enclosures; whether a given vent is suitable for a flight article, and what it outgasses, is a question for the maker and the program, and we say so rather than imply it.

Die-cut black microcellular urethane board-level shock and cushioning pads in several shapes on a white release liner, converted by H-O Products
Cushions that can fly. Die-cut PORON board-level pads on a liner. The firm 4701-50 and 4701-60 grades handle launch vibration and shock with low compression set, and their datasheets report ASTM E595 results inside the NASA limits; the very soft 4701-30 sits at the limits and the slow-rebound 4790-92 exceeds them.

Question 5: EMI in a box full of switching regulators, optical transceivers and radios

An orbital compute node packs kilowatts of switching power conversion next to optical inter-satellite links (Google's bench demonstrator carried 800 Gbps each way on a single transceiver pair, against a stated requirement of tens of terabits per second) and RF downlinks. The emissions and susceptibility budget is set by the spacecraft and tested to MIL-STD-461 rather than FCC Part 15, but the hardware is familiar from any dense enclosure: conductive elastomer gaskets at box seams and connector flanges, board-level shield-can gaskets and ground pads, foil and conductive-fabric tapes. The silver-filled shielding elastomers we convert to MIL-DTL-83528 Types A, B and D, 2368 (silver-plated-aluminium silicone, Type B), 2569 (silver-plated-copper silicone, Type A, QPL-listed) and 2486-70 (silver-plated-aluminium fluorosilicone, Type D, for fuel and fluid exposure), are the choices where a QPL listing or a fluid environment is specified. BISCO EC-2130, a 30 Shore A nickel-graphite silicone listing 110 to 130 dB from 100 MHz to 10 GHz per the MIL-G-83528 method with a 3.33 W/m·K thermal conductivity, is the soft option for low closure force on thin-walled boxes. None of those product pages carries an E595 result; the maker, SSP, states on its own site that 2368-65 and 2486-70 meet the ASTM E595 TML and CVCM requirements, and the conductive 502-40-V0 and 502-60-V0 grades list the data as available on request, so the report is something to ask for rather than assume. For a contamination-controlled node the EMI gasket is screened like everything else, and the conductive pressure-sensitive adhesive on it is screened with it. Our telecom and data-center EMI shielding page covers the enclosure-level choices.

Die-cut board-level EMI shield-can gaskets, conductive ground pads and foil strips laid out on a release liner
Board-level shielding, screened like everything else. Shield-can gaskets, ground pads and foil strips die-cut on a liner. In a spacecraft the gasket's conductive adhesive is part of the outgassing budget, and the shielding figures on the datasheet are measured to the MIL-DTL-83528 method, not to the box.

Question 6: Insulation and MLI, where heat must not go

The same node that is desperate to shed heat from its processors has places it must keep warm, batteries above all, and faces it must decouple from the radiator. Multilayer insulation is built from polyimide films: Kapton HN and FEP-coated Kapton FN are the layer and heat-sealable face materials, and converting them into blanket layers, spacers and tabs with the vent paths cut in is routine slitting and die-cutting work; our spacecraft material-selection article covers the blanket side. Where a thin conformal barrier is needed on a bracket, a battery face or an enclosure wall, the AeroZero polyimide-aerogel films give 0.037 to 0.049 W/m·K in 0.19 to 0.29 mm; the AZ-TPS 102, 103 and 104 constructions on acrylic adhesive are the ones with E595 results, while the silicone-adhesive versions (AZ-TPS 100, 101, PI 100 and the aluminised VDA PI 100) are the ones to screen before use. SOLIMIDE polyimide foam at 8 kg/m³ is the lightweight, non-wicking fill for thermal and acoustic lagging and reports below 1.0% and 0.1%. Aerogel blankets, ArmaGel XGC to −292 °F (−180 °C), Cryogel Z for sub-ambient service and Pyrogel XTE to 1,200 °F (about 650 °C), are the answer for cryogenic lines and hot structure rather than for the compute bay, and are covered on the cryogenic and space systems insulation page.

Cleanroom technician holding a roll of amber polyimide film up to the light
The blanket layer, before it is a blanket. Polyimide film is the working material of multilayer insulation: Kapton HN has no melting point and has been used from −269 to +400 °C, and it is converted into blanket layers, spacers and tabs by slitting and die-cutting, with the vent paths cut in.
Finished die-cut SOLIMIDE polyimide foam parts converted by H-O Products, shown with foil-faced and perforated foam sheet stock
Eight kilograms per cubic metre, and screened. Die-cut SOLIMIDE polyimide foam with foil-faced and perforated stock. The aerospace grades report ASTM E595 results below 1.0% TML and 0.1% CVCM and a 200 °C continuous rating, which is why they turn up as lagging and acoustic fill where every gram and every volatile counts.

Where a converter fits, and what to send

H-O does not run ASTM E595, does not qualify hardware for flight and does not design the thermal system. What we do is convert the screened materials above into the parts the drawing calls for: die-cut and kiss-cut gap pads and insulators with pull tabs on liners, slit and laminated film layers for MLI, PORON cushions and spacers, silicone and conductive-elastomer gaskets, SOLIMIDE and aerogel pieces, kitted by assembly and bagged with the manufacturer's data sheet and lot traceability, under our ISO 9001:2015 certified quality management system in Winsted, Connecticut. The quote is faster and the part is right when the request carries:

  • What the part sits near. Optics, a laser-link aperture, RF connectors, a cold surface or the radiator decide the outgassing requirement and the temperature band before any property does.
  • The outgassing requirement, and the paperwork. ASTM E595 to the NASA limits, a program-specific limit, or none; and whether the E595 report or a certificate of conformance must travel with the part.
  • The service temperature band at that location, including the cold end and the number of cycles expected.
  • For interface parts, the heat flux and the allowable temperature drop, the gap at nominal and at tolerance extremes, and the clamping pressure available. That fixes the grade and the thickness.
  • For cushions and isolators, the load case: random vibration level, shock, the mass supported and the deflection allowed.
  • Geometry, adhesive, format and quantities. Outline and thickness with tolerances; whether a pressure-sensitive adhesive is wanted and on which face (its outgassing counts too); sheet, roll, die-cut or kiss-cut on a liner; prototype and production quantities; kitting and bagging requirements for cleanroom integration.
Die-cut thermal interface pads in several grades and colours on release liners, with pull tabs, converted for an electronics assembly
What leaves Winsted. Die-cut thermal interface pads with pull tabs on liners, kitted by assembly. In orbit the temperature drop across each of these is paid for in radiator area, so the grade, the thickness and the deflection the clamp delivers are design variables, not packaging details.

Our how-to-spec guide for spacecraft and launch-vehicle materials walks through the nine facts engineering uses and what each one decides.

Have an orbital compute part reviewed

Send what the part sits near, the outgassing and temperature requirements, the heat flux or load case, the geometry and quantities. We will confirm the candidate materials against their current datasheets, tell you plainly which grades carry published E595 results and which do not, and convert samples on your geometry.

24-hour prototypes on in-house materials; otherwise samples typically ship in 3 to 5 business days for common die-cut configurations; standard production runs about two weeks; special orders are quoted to the job.

Family-owned since 1971 · ISO 9001:2015 certified organization · Send us a drawing and get back your part.

Related reading

Frequently asked questions

What is the biggest materials difference between a terrestrial server and an orbital compute node?

Heat has no air to leave through. On the ground the rack's heat ends up in facility air or water; in orbit it has to be conducted to a radiator and radiated away, and radiator area grows quickly as the temperature at the radiator falls. That makes every thermal interface in the path part of the radiator sizing, not a packaging detail. After that come the satellite rules: every polymer in the box is screened for outgassing (ASTM E595), the part sees a wider temperature band than any data hall, and the assembly has to survive launch vibration and the pressure drop of ascent.

Do thermal gap pads need outgassing data for a satellite?

If the pad sits inside a contamination-controlled volume or shares a line of sight with optics, sensors or cold surfaces, yes. Most gap pads are silicone, and the usual concern is silicone volatiles condensing where they are not wanted. The Bergquist GAP PAD TGP grades on our pages do not show ASTM E595 results, so the grade-specific report has to be requested from the maker before the part is specified; silicone-free grades such as TGP 2200SF and TGP 40000SF remove the silicone but are not automatically screened. The SIL PAD TSP K1300 insulator is the interface material on our pages that reports vacuum weight loss (0.36% TML and 0.09% VCM to NASA SP-R-0022A).

Which PORON grades report ASTM E595 results that pass the NASA limits?

As shown on the Rogers datasheets reproduced on our product pages: PORON 4701-60 (0.6 to 0.7% TML, 0.02 to 0.05% CVCM across its three densities), PORON 4701-50 (0.6 to 0.8% TML, 0.04 to 0.06% CVCM), PORON AquaPro 37 (0.58% TML, 0.02% CVCM) and PORON AquaPro 4701-41 (0.84 to 1.0% TML, 0.04 to 0.06% CVCM, the 480 kg/m³ grade right at the TML limit) sit inside the 1.0% and 0.10% limits. PORON 4701-30 sits at the limits (1.0 to 1.3% TML, 0.1 to 0.2% CVCM) and exceeds them in its 400 kg/m³ grade; PORON 4790-92 (1.63 to 1.73% TML, 0.14 to 0.29% CVCM) exceeds both; PORON 4701-40V0 reports 1.07% TML with no CVCM published. The values are the maker's, at the maker's test conditions, and are confirmed against the current datasheet at order.

Can a silicone foam gasket be used in a spacecraft electronics box?

Not on the strength of its ground-side heritage. BISCO HT-800 cellular silicone, a common enclosure gasket, reports 0.98% TML and 0.25% CVCM, which passes the mass-loss limit and fails the condensables limit by two and a half times; HT-820 and HT-840 fail both. For a seal that must clear the screen, the solid silicones with published results are the starting point: SSP2390-60D platinum-cured silicone (0.05% TML, 0.004% CVCM in a third-party test of that grade) and Low Outgassing Silicone Sheeting (TML ≤1.00%, CVCM ≤0.10% for all four hardness grades). Our guide to reading E595 numbers on a datasheet explains why foams and peroxide-cured compounds tend to fail where solid, platinum-cured or post-cured grades pass.

What temperature range should orbital compute materials be designed for?

The one at the part's location, not the spacecraft's. NASA's thermal engineers quote the uncontrolled skin of the International Space Station at roughly +121 °C in sunlight and −157 °C in shadow, while an electronics bay is held within a much narrower band by the thermal design. So a radiator-side film or a blanket layer needs a material such as Kapton HN polyimide film, used from −269 to +400 °C, whereas a cushion inside the controlled bay can be a PORON grade rated to 90 °C continuous with a −40 °C (4701-60) or −51 °C (4701-30) embrittlement point. The Bergquist GAP PAD TGP 3000, 3500ULM and 6000ULM are rated −60 to +200 °C; the silicone-free TGP 2200SF only to +125 °C. Match the datasheet range to the zone and check the cold-end behaviour, not only the maximum.

How much radiator does a GPU need in orbit, and why does the interface material matter?

IEEE Spectrum's June 2026 analysis put a single 700 W accelerator at just under 3 m² of radiator if its heat reaches the radiator at 20 °C, about 1.4 m² at 60 °C and about 1 m² at 85 °C, growing roughly 40% over five years as the radiator surface degrades; a 40 kW rack-equivalent came out near 80 m². Radiated power rises with the fourth power of radiator temperature, so every degree dropped between the die and the radiator face, across the interface material, cold plate contact and structural joints, is paid for in radiator area and launch mass. A pad's temperature drop is its thermal impedance times the heat flux: a 0.34 °C·in²/W pad at 50 W/in² costs 17 °C.

Does H-O test outgassing or qualify parts for flight?

No. H-O Products is a die-cut converter. The ASTM E595 results belong to the material manufacturer and are quoted from its datasheet; flight qualification, contamination-control budgets and thermal design belong to your program. What H-O does is convert the screened materials to your drawing, kit them by assembly, and ship them with the manufacturer's data sheet and lot traceability under our ISO 9001:2015 certified quality management system. If a grade you want has no published E595 result, we will say so rather than send a sample as though it were screened.

What should an RFQ for an orbital data-center part include?

What the part sits near (optics, RF, a cold surface, the radiator), the outgassing requirement and whether an E595 report must accompany the part, the service temperature band at that location, the heat flux and allowable temperature drop for any interface part, the launch load case or isolation requirement, geometry and thickness with tolerances, the adhesive requirement, prototype and production quantities, and whether a certificate of conformance or lot traceability to the manufacturer's certificate is required. Our spacecraft how-to-spec guide lists the nine facts engineering uses and what each one decides.

Request a quote

Request a quote for your orbital compute or spacecraft parts

Send H-O what the part sits near, the outgassing and temperature requirements, the heat flux or load case, the geometry, the adhesive requirement and quantities. Engineering reviews every RFQ, confirms the material against the manufacturer's current datasheet, and converts samples on your geometry.

Contact
Company address
Your application
Part & quantity
Typical response in one business day. 24-hour prototypes on in-house materials; otherwise samples typically 3–5 business days; production in about 2 weeks.

Last updated · Reviewed by H-O Products engineering (ISO 9001:2015 certified organization).

References

  • Google Research, Exploring a space-based, scalable AI infrastructure system design (Project Suncatcher), 4 November 2025: dawn–dusk sun-synchronous orbit, 81-satellite illustrative configuration at about 650 km, Trillium TPU proton-beam results (67 MeV; no hard failures to 15 krad(Si); HBM irregularities after 2 krad(Si)), 1.6 Tbps bench demonstrator, two prototype satellites with Planet by early 2027, thermal management listed among open challenges. research.google
  • CNBC, Nvidia-backed Starcloud trains first AI model in space as orbital data center race heats up, 10 December 2025: Starcloud-1 launched November 2025 with an Nvidia H100; ran Google's Gemma and trained a small model (nanoGPT) in orbit; next satellite planned for October 2026 with H100s and Blackwell. cnbc.com
  • Axiom Space, Orbital Data Centers program page: the first two ODC nodes "successfully launched to low-Earth orbit on January 11, 2026" with the first tranche of Kepler Communications' optical relay network constellation; compatible with Space Development Agency Tranche 1 optical communication standards. axiomspace.com
  • FCC Space Bureau, public notice accepting for filing SpaceX's application for a non-geostationary system of up to one million satellites at 500 to 2,000 km for orbital data centers (DA 26-113, February 2026; comments due 6 March 2026). Summary via Benton Institute
  • A. Cavalier, Why Orbital Data Centers Are Harder Than Silicon Valley Thinks, IEEE Spectrum, 11 June 2026: radiator area per 700 W chip at 20, 60 and 85 °C; 40% growth over five years; about 80 m² per 40 kW rack-equivalent; solar irradiance 1,361 W/m²; radiators and arrays at 65 to 70% of satellite mass. spectrum.ieee.org
  • S. G. Turyshev (NASA Jet Propulsion Laboratory), Orbital Data Centers: Spacecraft Constraints and Economic Viability, arXiv:2604.27197, April 2026: 1 MW base case with about 2,500 m² of radiator and 5,640 m² of photovoltaics; 29.4 kg/kW for photovoltaics, storage and radiators. arxiv.org
  • NASA Johnson Space Center thermal specialists quoted in Staying Cool on the ISS (Space Daily, 2001): uncontrolled ISS surfaces at about 250 °F (121 °C) in sunlight and −250 °F (−157 °C) in shadow; heat moved by water and ammonia loops to radiators and rejected as infrared. spacedaily.com
  • ASTM E595, Standard Test Method for Total Mass Loss and Collected Volatile Condensable Materials from Outgassing in a Vacuum Environment (24 h at 125 °C in vacuum, 25 °C collector); NASA-STD-6016, Standard Materials and Processes Requirements for Spacecraft (TML ≤1.0%, CVCM ≤0.10% screening limits); NASA SP-R-0022A, the predecessor vacuum-stability specification cited on the SIL PAD TSP K1300 datasheet; NASA Outgassing Database.
  • Specialty Silicone Products, ASTM E595 Outgassing and EMI Elastomers (SSP-2368-65 and SSP-2486-70 stated to meet the ASTM E595 TML and CVCM requirements) and the Exova OCM ASTM E595-15 report no. 351714 on SSP2390-60D (TML 0.050%, CVCM 0.004%, WVR 0.041%). sspinc.com
  • MIL-STD-461, Requirements for the Control of Electromagnetic Interference Characteristics of Subsystems and Equipment; MIL-DTL-83528, Gasketing Material, Conductive, Shielding Gasket, Electronic, Elastomer, EMI/RFI, and its Qualified Products List.
  • Manufacturer technical data sheets for every grade named, as reproduced on the linked H-O product pages: Henkel (Bergquist GAP PAD TGP, SIL PAD TSP), Rogers Corporation (PORON, BISCO), NeoGraf Solutions (SpreaderShield, eGRAF HiTherm), Specialty Silicone Products (SSP2390, SSP2575, 2368, 2569), Blueshift Materials (AeroZero), the Kapton® trademark owner (DuPont, now Qnity Electronics), Aspen Aerogels (Cryogel, Pyrogel), Armacell (ArmaGel), W. L. Gore & Associates (GORE protective vents), and the respective producers of the SOLIMIDE polyimide foams, the 2486-70 fluorosilicone, the 502-series conductive silicones and the Low Outgassing Silicone Sheeting, whose technical data sheets are attached to each product page.

Bergquist, GAP PAD™ and SIL PAD™ are trademarks of Henkel; PORON® and BISCO® of Rogers Corporation; eGRAF®, HiTherm™ and SpreaderShield™ of NeoGraf Solutions; Kapton® of DuPont de Nemours, Inc. or its affiliates and successors (Qnity Electronics); SOLIMIDE® of its manufacturer as named on the product datasheet; AeroZero® of Blueshift Materials; Cryogel® and Pyrogel® of Aspen Aerogels; ArmaGel® of Armacell; GORE® of W. L. Gore & Associates. Nvidia, H100, Google, Gemma, TPU, Starcloud, Axiom Space, Kepler, Planet and SpaceX are the marks of their owners and are referenced for identification only; none of those organizations is a customer of or affiliated with H-O Products unless separately stated. Outgassing, thermal and electrical values quoted in this article are as published on the manufacturers' technical data sheets at the stated test conditions, are not specifications, and are confirmed against the manufacturer's current data sheet at the time of order.

H-O Products is a precision die-cut converter, not a raw-material producer, a testing laboratory or a spacecraft designer; we do not test materials to ASTM E595, do not qualify parts for flight, and do not design or certify the thermal, structural or electromagnetic systems the parts go into. Contamination-control limits, thermal budgets and flight qualification are set and verified by your program.

H-O Products is an ISO 9001:2015 certified organization; that certification covers our quality management system, not individual materials or parts. Grade-specific values are confirmed against the manufacturer's current technical data sheet and an engineering drawing review. All parts are custom manufactured to order and minimum production run quantities apply.

H-O Products Corp · Precision die-cut converting · ISO 9001:2015 certified organization