AP/ArmaFlex Duct Liner/Wrap is a black, flexible, fiber-free, closed-cell elastomeric duct insulation supplied in sheet and roll form, with a declared thermal conductivity as low as 0.0353 W/(m·K) at 75°F (24°C) for NBR/PVC-based walls. It is rated for service from -297°F to 220°F (-183°C to 105°C) on 3/8″ through 1″ NBR/PVC-based walls, or up to 300°F (150°C) on 1-1/2″ and 2″ EPDM-based walls, and is available with or without factory-applied pressure-sensitive adhesive (PSA). Surface burning characteristics meet a 25/50 rating (Flame Spread Index less than 25, Smoke Developed Index less than 50) per ASTM E84 and UL 723.

Key Properties

  • Thermal Conductivity: λd ≤ 0.0353 W/(m·K) at 75°F (24°C) [k ≤ 0.245 Btu·in/(h·ft²·°F)] for 3/8″ through 1″ NBR/PVC walls; λd ≤ 0.040 W/(m·K) at 75°F (24°C) [k ≤ 0.28 Btu·in/(h·ft²·°F)] for 1-1/2″ and 2″ EPDM walls (ASTM C518, ASTM C177)
  • Water Vapor Permeability: 0.05 perm-inch (0.725 x 10⁻¹³ kg/(s·m·Pa)) for NBR/PVC products; 0.08 perm-inch (1.16 x 10⁻¹³ kg/(s·m·Pa)) for EPDM products (ASTM E96, procedure A)
  • Service Temperature Range: -297°F to 220°F (-183°C to 105°C) for 3/8″ through 1″ Walls (NBR/PVC-based); -297°F to 300°F (-183°C to 150°C) for 1-1/2″ and 2″ Walls (EPDM-based) (ASTM C534)
  • Fire Performance: Flame Spread Index less than 25 and Smoke Developed Index less than 50, 25/50 rated (ASTM E84 and UL 723, CAN/ULC S102)
  • Density: 3 to 6 lb/ft³ (48 to 96 kg/m³) (ASTM D1667)
  • Water Absorption: 0.2% by volume (ASTM C209, ASTM C1763)

We want to help!

Enter your information and we'll get you in touch with our knowledgable staff. We know how important to the right product for your project.

Call

E-Mail

Request a Consultation

    Get a material engineering quote

    Send a drawing set, BOM, or product spec. We typically respond within one business day with a material recommendation, prototype lead time, and TDS verification against your requirements.

    Contact
    Part & quantity
    Typical response in one business day. Prefer the phone? Call (860) 469-1144.

    Physical Properties

    Property Value Test Method
    Density 3 to 6 lb/ft³ (48 to 96 kg/m³) ASTM D1667
    Sheet Size (Width x Length) 36″ x 48″ (0.915 m x 1.22 m)
    Roll Width 48″ (1.22 m) (all thicknesses); 56-1/4″ (1.42 m), 59″ (1.49 m), 60″ (1.5 mm) for 1/2″, 1″, and 1-1/2″ thick (13, 25, 38 mm)
    Available Thickness — AP ArmaFlex Duct Liner/Wrap 1/2″ and 1″ (13, 25 mm)
    Available Thickness — AP ArmaFlex FS Duct Liner/Wrap 1-1/2″ and 2″ (38, 51 mm)

    Thermal Properties

    Property Value Test Method
    Service Temperature, 3/8″ through 1″ Walls (NBR/PVC-based) -183°C to 105°C (-297°F to 220°F) ASTM C534
    Service Temperature, 1-1/2″ and 2″ Walls (EPDM-based) -183°C to 150°C (-297°F to 300°F) ASTM C534
    Full Bonding Sheet Insulation Remark 82°C (180°F)
    Declared Thermal Conductivity, 3/8″ through 1″ Walls (NBR/PVC), at 75°F (24°C) λd ≤ 0.0353 W/(m·K); k ≤ 0.245 Btu·in/(h·ft²·°F) ASTM C518, ASTM C177
    Declared Thermal Conductivity, 3/8″ through 1″ Walls (NBR/PVC), at 100°F (38°C) λd ≤ 0.037 W/(m·K); k ≤ 0.257 Btu·in/(h·ft²·°F) ASTM C518, ASTM C177
    Declared Thermal Conductivity, 1-1/2″ and 2″ Walls (EPDM), at 75°F (24°C) λd ≤ 0.040 W/(m·K); k ≤ 0.28 Btu·in/(h·ft²·°F) ASTM C518, ASTM C177
    Declared Thermal Conductivity, 1-1/2″ and 2″ Walls (EPDM), at 100°F (38°C) λd ≤ 0.041 W/(m·K); k ≤ 0.289 Btu·in/(h·ft²·°F) ASTM C518, ASTM C177
    R-Value at 1/2″ (13 mm) 2.1
    R-Value at 1″ (25 mm) 4.2
    R-Value at 1-1/2″ (38 mm) 6
    R-Value at 2″ (50 mm) 8

    Flame & Fire Performance

    Property Value Test Method
    Hot Surface Performance Meets requirements ASTM C411
    Surface Burning Characteristics Flame Spread Index less than 25 and Smoke Developed Index less than 50, 25/50 rated ASTM E84 and UL 723, CAN/ULC S102 (up to 1″ thickness)

    Environmental Performance

    Property Value Test Method
    Water Vapor Permeability (NBR/PVC products) 0.05 perm-inch (0.725 x 10⁻¹³ kg/(s·m·Pa)) ASTM E96, procedure A
    Water Vapor Permeability (EPDM products) 0.08 perm-inch (1.16 x 10⁻¹³ kg/(s·m·Pa)) ASTM E96, procedure A
    Water Absorption 0.2% by volume ASTM C209, ASTM C1763
    Mold Growth Pass ASTM G21, ASTM C1338
    Fungal Growth Pass ASTM G21, ASTM C1338
    Outdoor Use Painting with WB finish or other protective jacketing is required to prevent damage in exterior applications and to comply with the insulation protection sections of the IECC and ASHRAE 90.1
    Erosion Resistance Does not break away, flake off, or show evidence of delamination at velocities of 10,000 ft/min ASTM C1071

    Acoustic Properties

    Property Value Test Method
    Sound Absorption Average (SAA) at 1″ (25 mm) 0.38 ASTM E909
    Sound Absorption Average (SAA) at 1-1/2″ (38 mm) 0.49 ASTM E909
    Sound Absorption Average (SAA) at 2″ (50 mm) 0.51 ASTM E909
    Octave Band Sound Absorption Coefficient at 125 Hz (1″ / 1-1/2″ / 2″) 0.01 / 0.07 / 0.14
    Octave Band Sound Absorption Coefficient at 250 Hz (1″ / 1-1/2″ / 2″) 0.13 / 0.26 / 0.62
    Octave Band Sound Absorption Coefficient at 500 Hz (1″ / 1-1/2″ / 2″) 0.39 / 0.92 / 0.44
    Octave Band Sound Absorption Coefficient at 1000 Hz (1″ / 1-1/2″ / 2″) 0.69 / 0.31 / 0.43
    Octave Band Sound Absorption Coefficient at 2000 Hz (1″ / 1-1/2″ / 2″) 0.29 / 0.49 / 0.51
    Octave Band Sound Absorption Coefficient at 4000 Hz (1″ / 1-1/2″ / 2″) 0.26 / 0.53 / 0.45
    Sound Transmission Class (STC) at Nom. 1″ (25 mm) 25 ASTM E413

    Compliance

    • GREENGUARD Gold Certified — Compliant
    • ASTM C534 Grade 1 Type II Sheets (NBR/PVC) — Compliant
    • ASTM C534 Grade 2 Type II Sheets (EPDM) — Compliant
    • ASTM E84, UL 723 — Compliant
    • CAN/ULC S102 — Compliant (up to 1″ thickness)
    • City of New York Approval MEA 107-89M — Compliant
    • Title 24 California Building Energy Efficiency Standards — Compliant
    • MIL-P-15280J, FORM S — Compliant
    • Manufactured without CFCs, HFCs, HCFCs, PBDEs, or Formaldehyde — Compliant
    • Made with EPA Registered MICROBAN® Antimicrobial Product Protection — Compliant
    • ASTM C1534, Type 1 — Compliant
    • ASTM G21 / ASTM C1338 — Compliant
    • ASTM D1056, 2C1 — Compliant
    • UL 94 — Compliant (File Number E535094)
    • Conforms to International Mechanical Code (IMC), International Energy Conservation Code (IECC), and International Residential Code (IRC) — Compliant
    • ISO 9001 — Compliant (Armacell North America quality management systems certified by Intertek)
    Standard Thicknesses:1/2", 1" (13, 25 mm) — AP ArmaFlex Duct Liner/Wrap; 1-1/2", 2" (38, 51 mm) — AP ArmaFlex FS Duct Liner/Wrap
    Standard Colors:Black
    Supply Formats:Sheet stock, Slit rolls, Precision die-cut components, Kiss-cut parts, Laminated constructions, Sheet: 36" x 48" (0.915 m x 1.22 m), Roll widths: 48" (1.22 m, all thicknesses), 56-1/4" (1.42 m), 59" (1.49 m), 60" (1.5 mm) for 1/2", 1", and 1-1/2" thick material, Available with or without factory-applied pressure-sensitive adhesive (PSA)
    Misc Notes:Custom dimensions and converted formats available based on application requirements and production volume.
    • Interior duct liner insulation for sheet metal HVAC ductwork
    • Exterior duct wrap insulation for HVAC ductwork
    • Indoor air quality-sensitive HVAC insulation in occupied building spaces
    • HVAC noise attenuation and acoustic duct treatment
    • Long-service-life insulation for mechanical equipment ductwork

    Common industries: HVAC and mechanical contracting, commercial and institutional building construction, industrial ventilation.

    AP/ArmaFlex Duct Liner/Wrap is a black, flexible, closed-cell elastomeric thermal and acoustical insulation engineered specifically for HVAC ductwork, supplied in sheet and roll form and available with or without a factory-applied pressure-sensitive adhesive. As a fiber-free, closed-cell material, it is designed to safeguard indoor air quality, attenuate HVAC noise, and reduce energy waste, with a service life intended to match that of the mechanical equipment it insulates. The product line is offered in two wall-thickness/polymer configurations: 1/2″ and 1″ (13 and 25 mm) NBR/PVC-based walls, and 1-1/2″ and 2″ (38 and 51 mm) EPDM-based walls carrying a higher maximum service temperature.

    The material demonstrates low water vapor permeability and low water absorption (0.2% by volume), supporting condensation control performance in duct applications, and passes mold and fungal growth resistance testing per ASTM G21 and ASTM C1338. Acoustic performance is documented via Sound Absorption Average (SAA) values ranging from 0.38 to 0.51 depending on thickness, and a Sound Transmission Class (STC) of 25 at nominal 1″ thickness. The insulation resists erosion at airstream velocities up to 10,000 ft/min without breaking away, flaking off, or delaminating, and for exterior applications requires painting with a WB finish or other protective jacketing to prevent weather and UV damage. Compliant with GREENGUARD Gold Certification; ASTM C534 Grade 1 Type II (NBR/PVC sheets) and Grade 2 Type II (EPDM sheets); ASTM E84 and UL 723; CAN/ULC S102; City of New York Approval MEA 107-89M; Title 24 California Building Energy Efficiency Standards; MIL-P-15280J, FORM S; ASTM C1534, Type 1; ASTM G21/C1338; ASTM D1056, 2C1; UL 94 File Number E535094; manufacture without CFCs, HFCs, HCFCs, PBDEs, or Formaldehyde; EPA registered MICROBAN® antimicrobial product protection; conformance with the International Mechanical Code (IMC), International Energy Conservation Code (IECC), and International Residential Code (IRC); and ISO 9001 certified quality management systems.

    What differentiates AP/ArmaFlex Duct Liner/Wrap from other duct insulation grades?

    AP/ArmaFlex Duct Liner/Wrap is offered in two configurations: a 1/2" and 1" (13, 25 mm) NBR/PVC-based construction rated to 220°F (105°C), and a 1-1/2" and 2" (38, 51 mm) EPDM-based AP ArmaFlex FS construction rated to a higher 300°F (150°C) service temperature. As a fiber-free, closed-cell elastomeric material, it also eliminates the fiber shedding associated with fibrous duct insulation, supporting indoor air quality performance that is GREENGUARD Gold Certified.

    Why does thermal conductivity matter for HVAC duct insulation?

    Thermal conductivity directly determines the energy efficiency of the ductwork system, since a lower λd/k-value reduces heat gain or loss through the duct wall and lowers the R-value needed to meet building energy code requirements. AP/ArmaFlex Duct Liner/Wrap achieves a declared thermal conductivity as low as 0.0353 W/(m·K) at 75°F (24°C), supporting the product's stated role in reducing energy waste.

    What is the service temperature range for AP/ArmaFlex Duct Liner/Wrap?

    -297°F to 220°F (-183°C to 105°C) for 3/8" through 1" Walls (NBR/PVC-based), and -297°F to 300°F (-183°C to 150°C) for 1-1/2" and 2" Walls (EPDM-based), per ASTM C534.

    lity-regulated environments?

    Yes. The material is 25/50 rated (Flame Spread Index less than 25, Smoke Developed Index less than 50) per ASTM E84, UL 723, and CAN/ULC S102, carries UL 94 File Number E535094, and is GREENGUARD Gold Certified, in addition to City of New York Approval MEA 107-89M and conformance with the International Mechanical Code (IMC), IECC, and IRC.

    How should AP/ArmaFlex Duct Liner/Wrap be specified?

    Specify grade (AP ArmaFlex Duct Liner/Wrap or AP ArmaFlex FS Duct Liner/Wrap), thickness, adhesive option (with or without factory-applied PSA), compliance requirements, dimensional tolerances, and finished format (sheet or roll).