Metal-Detectable Silicone for Food, Beverage & Pharmaceutical Equipment
Doc No SIL-MAT-04 Rev 1.0 Updated 2026-09 Document Material Guide · Metal-Detectable Silicone Classification Published · Engineering reference
Silicone materials guide · Contamination control

Metal-Detectable Silicone for Food, Beverage & Pharmaceutical Equipment

Every gasket on a processing line wears, and a fragment of ordinary silicone is invisible to the metal detectors already installed on that line. Metal-detectable silicone carries a ferrous-detectable additive through the whole part so an appropriately configured detector can flag a fragment, the affected product can be segregated, and the worn seal can be found. This page covers the material, the manufacturer test conditions, and what H-O converts it into.

Part of the Silicone Materials guide. Start at the hub page for the forms, the selection matrix and the material families; this page goes deep on one topic.

LocationConverted in Winsted, CT · Family-owned since 1971 · ISO 9001:2015 certified organization · APQP / PPAP support on contract
30-second read

Metal-detectable silicone is a food-contact silicone (solid or sponge) compounded with a ferrous-detectable additive. Silicone Engineering’s metectSil™ family (ST, XP, XS solids; SP sponge; newer NG 60) is the reference product; H-O’s catalog lists a Metal Detectable Grade sheet in 40–85 Shore A with a 4 kg magnet-pull test and FDA 21 CFR 177.2600 compliance. Detectability is system-dependent: validate the material on the plant’s own detector and product. H-O converts the sheet into gaskets, seals, pads, washers, strips and adhesive-backed parts; it does not manufacture the material. Skip to the quote form →

Blue metal-detectable silicone gasket beside a white FDA-grade silicone gasket on stainless steel
A metal-detectable silicone gasket (blue, ferrous-loaded) next to a plain white FDA-grade gasket. The color is for visual detection; the additive is what the in-line detector sees.
Quick Answer

Metal-detectable silicone is a silicone rubber compounded with a ferrous-detectable additive dispersed through the material, so that a fragment from a worn gasket can be flagged by an in-line metal detector or captured by a magnet separator and the affected product segregated. It is used for seals and gaskets on food, beverage, dairy and pharmaceutical equipment where a lost fragment is a recall. Detection depends on the detector, aperture, calibration, fragment size and shape, and product effect, so a manufacturer’s test specimen is a test condition, not a threshold for your line.

Property values are quoted from the source manufacturer TDS or the cited standard, not from H-O testing. H-O converts sheet and roll silicone; ratings belong to the specific grade and a finished assembly earns its own rating at the system level.

When To Spec What
  • Flange, valve and pump seals: solid detectable sheet, 40–85 Shore A
  • Door, lid and hopper seals: detectable sponge (metectSil™ SP class)
  • Compliance: FDA 21 CFR 177.2600; EC 1935/2004 per grade
How it works
  1. 1
    Send drawing
    Upload a DXF, STEP, or PDF, or describe the gasket, pad, or insulator and its environment. A sample part works too.
  2. 2
    Material review
    Engineering checks the candidate grade against the manufacturer TDS: closure force, compression set, service temperature, fluid exposure, flame or regulatory requirement, and adhesive compatibility.
  3. 3
    Prototype
    24-hour prototypes on in-house materials; otherwise samples typically ship in 3–5 business days for common die-cut configurations on materials we commonly convert. Made-to-order; MOQ varies by material and part.
  4. 4
    Production
    Standard production runs ship about 2 weeks after drawing approval, including kiss-cut-on-liner and laminated configurations. Expedited service available. Ongoing parts run with lot traceability and TDS records.
Contamination control

Metal-Detectable Silicone for Food, Beverage & Pharmaceutical Equipment

Every gasket on a processing line wears. Ordinary silicone is invisible to the metal detectors and magnet separators already installed on those lines, so a fragment of a worn seal travels with the product until a customer finds it. Metal-detectable silicone incorporates a ferrous-detectable system in the rubber itself, so an appropriately configured in-line detector can flag a fragment, the affected product can be segregated, and the deteriorating seal can be found and replaced before the next fragment leaves.

Why it exists: the engineering problem

Silicone is the default elastomer in food, beverage, dairy, and pharmaceutical equipment because it tolerates steam, hot water, clean-in-place chemistry, and repeated thermal cycling while meeting FDA 21 CFR 177.2600 and EC 1935/2004. Its weakness is mechanical: modest tear strength and abrasion resistance. Over thousands of cycles, a door seal, hopper gasket, pipe-flange gasket, or valve seat can nick, abrade, or fragment. Because the fragments are soft, light, and non-metallic, neither an X-ray system tuned for bone and stone nor a metal detector will reliably see them. Hazard analysis (HACCP) treats this as a physical-hazard control point, and the usual controls are inspection intervals and preventive replacement, both of which depend on someone noticing wear.

Metal-detectable silicone changes the failure from silent to detectable. The material is compounded with a ferrous additive that gives fragments a magnetic and conductive signature. Silicone Engineering, which developed the metectSil™ family, describes the purpose directly: it was “first created for the food and beverage industry seals, helping to identify eroding seal particles, which would be recognised by an in-line metal detector, preventing them from entering the process line.” [44]

How metal-detectable silicone works in a processing line Left: a gasket cross-section in a flange with a ferrous-detectable additive dispersed through the silicone; a small fragment has broken away. Center: the fragment travels with product on a conveyor through a metal detector aperture. Right: the detector signals, a reject gate diverts the affected product, and maintenance traces the fragment back to the worn seal. A caption notes that detection depends on detector type and calibration, aperture size, fragment size and shape, product effect, and line speed. CONTAMINATION CONTROL · DETECTABLE SEAL FRAGMENT PATH 1 · Seal wears upper flange detectable silicone gasket lower flange Ferrous-detectable additive is dispersedthrough the whole cross-section, so anyfragment carries the signature. 2 · Fragment travels with product metal detector aperture Balanced-coil detector senses the ferrous /conductive disturbance as the fragment passes.Sensitivity is set per product and aperture. 3 · Detect, reject, trace Detector signals · reject gate diverts Affected product segregated Worn seal located and replaced Detectability is system-dependent. Detector design and calibration · aperture size · fragment size and geometry · product effect (wet, salty, frozen) · conveyor speed · material formulation and additive loading
Figure 2. The detectable additive is dispersed through the entire gasket, so a fragment of any origin carries the signature. Whether a given fragment is caught depends on the detector and the line, which is why manufacturers report test conditions rather than a universal threshold.

How detection works, and why “detectable” is not a number

Industrial metal detectors use a balanced-coil system: a transmitter coil and two receiver coils inside an aperture. A conductive or magnetic object passing through disturbs the balance and produces a signal. The signal is set against a sensitivity threshold calibrated with certified test spheres (ferrous, non-ferrous, and stainless) for each product. Wet, salty, or frozen products generate their own signal (“product effect”) that forces the threshold higher; larger apertures are less sensitive at their centerline than small ones; and a fragment’s orientation and shape change the signal it produces. A ferrous-loaded silicone fragment is far more detectable than a plain silicone fragment of the same size, but the size it can be caught at depends on all of the above.

Silicone Engineering’s published test statement for metectSil™ reads: tests were “conducted using a 10mm long x 5mm wide x 3mm high piece of each type of metectSil™” on “the MET30+ Universal metal detector manufactured by Lock Inspection Systems Ltd.”, with results described as “outstanding” and detailed “test results … available upon request.” The manufacturer does not publish aperture size, sensitivity setting, or product type for that test. [45] That is the correct way to read any detectability claim: a specimen size, a detector, and a report on request, not a universal minimum fragment size.

Engineering callout

Detectability is system-dependent. No metal-detectable elastomer guarantees that every fragment will be found. Detection performance depends on detector design, aperture size, calibration and sensitivity setting, fragment size and geometry, product effect and packaging, conveyor speed, and the material’s additive loading. Validate the specific gasket material on the specific line with the plant’s own test protocol, and keep the result in the HACCP file. A manufacturer’s test specimen (for example, a 10 × 5 × 3 mm piece) is a test condition, not a detection threshold for your line.

The metectSil™ family (Silicone Engineering Ltd)

Silicone Engineering Ltd of Blackburn, Lancashire, UK, an HCR silicone manufacturer owned by Rogers Corporation since October 2021, develops and manufactures the metectSil™ range. [46] What the manufacturer’s current literature supports, as of the date of this draft: [45] [44] [46]

Grade (manufacturer designation)FormWhat the manufacturer statesVerification status for this page
metectSil™ ST (“Standard”)Solid sheetThree solid grades “with varying detection strengths” (increasing additive loading from ST to XS). Service temperature −60 to +230 °C. Solid grades “tested to and comply with” FDA 21 CFR 177.2600 for repeated food contact and EC 1935/2004. Resistant to ozone, UV, and weathering.Listed on the manufacturer material page (last revised 2021). Hardness options, colors, mechanical properties, thicknesses, and cure system are not published on the page; per-grade TDS is available from the manufacturer on request. Distributor data (e.g. ST60, blue, about 63 Shore A) is not manufacturer-verified and is not quoted here.
metectSil™ XP (“Premium”)Solid sheet
metectSil™ XS (“Super”)Solid sheet
metectSil™ SPClosed-cell spongeSponge form of the detectable material for lower-closure-force door, lid, and hopper seals.Named on the manufacturer page; no published firmness, density, or compliance table. Confirm food-contact status for the sponge separately from the solid grades.
metectSil™ NG 60Solid sheet, 60 Shore A, jet blackNewer-generation grade announced with FDA and BfR (German food-contact) approval.Supported by a 2021 manufacturer news release; not yet listed on the material page. Whether NG grades replace or supplement ST/XP/XS, and whether an NG sponge exists, should be confirmed with the manufacturer before a drawing callout.

No X-ray-detectable metectSil variant appears in the manufacturer’s literature; the family is metal-detectable only. Silicone Engineering’s other current ranges are kSil® (sheeting: solid, sponge, fabric-reinforced), kSil® V-0 (flame-retardant sponge and solid), kSil® VAC (membranes), neutraSil™ (antimicrobial), expanSil™ (sponge extrusions), and suraSil™ (solid extrusions). [42] H-O converts kSil® sheet and sponge grades listed in its catalog; H-O is not the manufacturer of any of these materials and does not represent itself as an authorized distributor.

Metal-detectable silicone in the H-O catalog

H-O currently lists a solid Metal Detectable Grade Silicone Sheeting in four durometers with a published magnet-pull test and FDA 21 CFR 177.2600 compliance. Values below are from the H-O product TDS. [47]

Property (test method)40 Shore A50 Shore A60 Shore A85 Shore A
Specific gravity (ASTM D297)1.291.311.361.56
Durometer, Shore A (ASTM D2240)40 ±550 ±560 ±585 ±5
Tensile strength, psi (ASTM D412)1,1001,0501,2501,050
Elongation, % (ASTM D412)800700800100
Tear, ppi Die B (ASTM D624)130130190100
Detectability: magnet pull test, 20.5 mm diameter magnet4 kg maximum pull (all grades)
Service temperature (per TDS)−85 °F to +525 °F (intermittent); peroxide-free, odorless, tasteless
ComplianceFDA 21 CFR 177.2600
Supply0.010–0.500 in gauges (contact H-O for availability); opaque colors; sheet, slit roll, die-cut, kiss-cut, laminated

A magnet-pull figure characterizes the ferrous loading of the material; it is a comparative material property, not a line-detection guarantee, and it should be read alongside a detector trial on the actual product. The higher specific gravity of these grades relative to unfilled silicone (1.29–1.56 versus about 1.1–1.2) is the additive.

Solid vs sponge, hardness, and color

  • Solid detectable sheet (40–85 Shore A in the H-O grade; the manufacturer’s ST/XP/XS solids) suits flange gaskets, valve and pump seals, hopper and chute liners, washers, and wear strips. Higher durometers resist extrusion and abrasion; 40–50 Shore A conforms to stainless flanges at lower bolt load.
  • Detectable sponge (metectSil™ SP class) suits door and lid seals on ovens, dryers, mixers, and enclosures where closure force is limited. Confirm the sponge grade’s food-contact status and compression set separately; blown sponge sets more than solid.
  • Color is a second line of defense. Detectable silicones are supplied in visually distinct colors (blue is the food-industry convention; the NG 60 grade is black), so a fragment is also findable by eye and camera. Specify color on the drawing.
  • Adhesive backing is possible for positioning, but in a food-contact zone the PSA needs its own compliance review, and many processors prefer mechanically retained gaskets in product-contact areas.

What H-O converts metal-detectable silicone into

H-O does not compound or manufacture detectable silicone; Silicone Engineering (metectSil™) and other mills develop and produce the material. H-O converts the sheet and roll stock into finished components to the customer’s drawing: custom flange and door gaskets, valve and pump seals, pads and wear strips, washers, slit strips, die-cut and kiss-cut parts, and adhesive-backed parts where the application permits. Parts can be supplied with lot traceability, first-article inspection, and 100% dimensional inspection on contract, and can be kitted by machine or line. See from silicone sheet to finished component.

Application checklist for a detectable gasket. (1) Which regulation(s) apply to the product zone: FDA 21 CFR 177.2600, EC 1935/2004 + BfR XV, 3-A, WRAS. (2) Detector type, aperture, and current test-sphere sensitivity on the line. (3) Product effect: dry, wet, salty, frozen. (4) Minimum fragment the plant wants to catch, and whether a magnet separator is also present. (5) Cleaning regime: CIP chemistry, temperature, and mechanical cleaning. (6) Closure force available at the joint, which decides solid vs sponge. (7) Color requirement. (8) Whether an adhesive is acceptable in the zone. Send these with the drawing and H-O can shortlist grades and arrange material samples for the plant’s own detector trial.

Engineering FAQ

Questions engineers ask about this topic

Direct answers with the source. The same questions appear in the page’s structured data.

6 questions · click a question to expand its answer

What is metal-detectable silicone and how does it work?

Metal-detectable silicone is a food-contact silicone (solid or sponge) compounded with a ferrous-detectable additive dispersed through the material, so that a fragment from a worn gasket can be flagged by an in-line metal detector or captured by a magnet separator and the affected product segregated. Silicone Engineering’s metectSil™ family (ST, XP, XS solids, SP sponge, and a newer NG 60 grade) is the reference product; H-O’s catalog lists a Metal Detectable Grade sheet in 40–85 Shore A with a 4 kg magnet-pull test and FDA 21 CFR 177.2600 compliance. Detection depends on detector type, aperture, calibration, fragment size and shape, and product effect, so the material must be validated on the actual line. [45] [47]

Can every metal detector find every fragment of metal-detectable silicone?

No. Silicone Engineering reports testing 10 × 5 × 3 mm specimens on a Lock Inspection MET30+ detector with detailed results available on request; that is a test condition, not a universal threshold. Balanced-coil detectors are calibrated per product with test spheres, sensitivity falls toward the aperture centerline and with larger apertures, wet or salty products raise the threshold, and orientation changes the signal. Run a detector trial with samples of the actual material on the actual line and record it in the HACCP file. [45]

Is metal-detectable silicone FDA compliant?

The grades on this page are. H-O’s Metal Detectable Grade sheet lists FDA 21 CFR 177.2600 compliance in all four durometers, and Silicone Engineering states its metectSil™ solid grades are tested to and comply with 21 CFR 177.2600 and EC 1935/2004, with the NG 60 grade also carrying BfR approval. Compliance is grade- and color-specific, so confirm it for the exact grade, and confirm the sponge version separately from the solid. [47] [45]

Is metal-detectable silicone also X-ray detectable?

Not by default. The metectSil™ family is documented by its manufacturer as metal-detectable only, and no X-ray-detectable variant appears in the current literature. X-ray systems detect density contrast; a ferrous-loaded silicone fragment is denser than plain silicone (specific gravity 1.29–1.56 versus about 1.1–1.2) but that does not guarantee detection in a given product. If X-ray detection is a requirement, it must be validated on the plant’s system with the actual material. [45] [47]

What hardness and colors is metal-detectable silicone available in?

H-O’s catalog grade is offered in 40, 50, 60 and 85 Shore A in opaque colors, 0.010–0.500 in thick. Silicone Engineering publishes three solid detection strengths (ST, XP, XS), a sponge (SP) and a 60 Shore A jet-black NG 60 grade; per-grade hardness and color tables are available from the manufacturer on request. Blue is the food-industry convention for visual detectability; specify the color on the drawing because it is a second line of defense. [47] [44]

Does H-O manufacture metectSil or metal-detectable silicone?

No. Silicone Engineering Ltd (a Rogers Corporation company) develops and manufactures metectSil™; other mills produce the detectable sheet in H-O’s catalog. H-O converts the sheet and roll stock into finished gaskets, seals, pads, washers, strips, die-cut and kiss-cut parts, and adhesive-backed parts where the application permits, with lot traceability and inspection on contract. H-O does not compound, mold or extrude the material and is not an authorized distributor for it. [46]

Sources for technical claims

References

Every quantitative claim on this page traces to one of the sources below. Reference numbers are shared across all eight pages of the Silicone Materials guide so a value cited as [4] here is the same source as [4] on any other page. Values change between data-sheet revisions; the revision on file at publication governs.

Show all 5 sources cited on this page tap to expand
5 sources · click to expand, or expand all
Silicone Engineering: kSil® sheeting and kSil® VAC membranes

kSil solid 30–80 Shore A, 0.3–20 mm, to 1,800 mm wide; sponge 150–600 kg/m³, 2–45 mm, closed cell; −60 to 230 °C; kSil VAC elongation 780–900%, to 4 mm, translucent. Current family list: kSil, kSil VAC, kSil V-0, metectSil, neutraSil, expanSil, suraSil. silicone.co.uk/ksil · kSil VAC · our materials

Silicone Engineering news: “metectSil™ Gains Food Approval” (NG 60)

metectSil NG 60: 60 Shore A, jet black, FDA and BfR approval; origin statement on identifying eroding seal particles with in-line metal detectors. Published 27 May 2021, last modified December 2024. silicone.co.uk/news

Silicone Engineering: metectSil™ material page and brochure

Grades ST, XP, XS (solid, “varying detection strengths”) and SP (sponge); −60 to +230 °C; FDA 21 CFR 177.2600 and EC 1935/2004 for solid grades; detection test on Lock Inspection MET30+ Universal with 10 × 5 × 3 mm specimens, results available on request. Page last revised March 2021; brochure uploaded September 2018. silicone.co.uk/metectsil · brochure (PDF)

Rogers Corporation: acquisition of Silicone Engineering (2021)

Rogers completed the acquisition of Silicone Engineering Ltd (Blackburn, UK) on 8 October 2021; positioned as Rogers’ European center of excellence for silicones. rogerscorp.com/news

H-O TDS: Metal Detectable Grade Silicone Sheeting

40/50/60/85 Shore A; SG 1.29–1.56; tensile 1,050–1,250 psi; elongation 100–800%; tear 100–190 ppi; magnet pull test 4 kg max (20.5 mm magnet); FDA 21 CFR 177.2600; −85 to +525 °F intermittent; 0.010–0.500 in. H-O product page · TDS (PDF)

Engineering review

Need help selecting a silicone?

Send H-O your drawing, operating temperature, environment, compression requirements, regulatory requirements, adhesive needs, and expected quantity. Our team reviews the application against current manufacturer data and helps identify appropriate material constructions for prototyping and production. We typically respond within one business day.

Contact
Your application
Compression, part & quantity
Typical response in one business day. 24-hour prototypes on in-house materials; otherwise samples typically 3–5 business days; production in 2 weeks. MOQ varies by material and part. Expedited service available. Prefer the phone? Call (860) 469-1144.
Continue reading

See also: the rest of the Silicone Materials guide

The guide is one hub and seven topic pages that share one set of sources and one set of numbers.

Silicone materials guideSilicone Materials hubEngineering guide to silicone materials: solid rubber vs sponge vs foam, selection matrix and decision flow, specialty silicones, and the material families H-O converts, with TDS-cited data.Read the guideSilicone materials guideFoam vs sponge vs solidHow cast silicone foam, closed-cell silicone sponge and solid silicone sheet differ in structure, CFD, compression set, sealing and mechanical behavior, with grade data from Rogers, Silicone Engineering and Saint-Gobain.Read the guideSilicone materials guideProperties: CFD & compression setCompression force deflection vs compression set for silicone gaskets: test methods, formulas, a 14-material benchmark, a worked closure-force example, and 18 engineering properties explained by how they are used.Read the guideSilicone materials guideSpecialty silicones & cure systemsFourteen specialty silicone families and the cure systems behind them: high-temperature, flame-retardant, low-outgassing, insulating, conductive, thermally conductive, fluorosilicone, medical, food-contact, antimicrobial, reinforced, high-tear, translucent and membrane grades, with what to evaluate and the design risk for each.Read the guideSilicone materials guideAdhesive-backed siliconeHow to put pressure-sensitive adhesive on silicone foam, sponge and solid gaskets: why acrylic fails on silicone, silicone PSA vs differential tape, peel and temperature data from 3M and Rogers, shelf life, and the mounting-aid rule.Read the guideSilicone materials guideSilicone vs other elastomersAn honest comparison of silicone with EPDM, nitrile, FKM, neoprene, cellular urethane and natural rubber: temperature ranges, where each beats silicone, cost tiers, and the eleven most common silicone selection mistakes.Read the guideProductMetal Detectable Grade Silicone Sheeting40/50/60/85 Shore A; magnet-pull test; FDA 21 CFR 177.2600.Read the guide
Get Quote →