Reticulated Foam
Doc No MAT-RETIC-01 Rev 1.0 Updated 2026-10 Document Material Guide · Reticulated Foam Classification Published · Engineering reference
Foam materials · Reticulated polyurethane

Reticulated Foam: 10 to 80 PPI Grades, Coatings and Specifications

Reticulated foam is open-cell polyurethane foam with its cell windows removed, leaving a skeleton of struts that lets air and water through while it holds back dust, debris and insects. H-O Products converts 34 reticulated grades, from 10 to 80 PPI in uncoated, acrylic coated, PVC coated and UL94 HF-1 versions plus FilterPore S-100X polyester, into weep baffles, filter pads, strips and acoustic covers cut to your drawing.

Best fit: window, door and curtain wall weep baffles · HVAC and air-conditioner filters · NEMA enclosure, generator and compressor ventilation · loudspeaker covers · filter media that needs a UL 900 Class 2 listing.

LocationConverted in Winsted, CT · Family-owned since 1971 · ISO 9001:2015 certified organization · 34 reticulated grades, 10 to 80 PPI
30-second read

Pick reticulated foam on three choices. Pore size (PPI) sets the balance between flow and filtration: our 10 PPI grade passes 25.5 cfm, the 45 PPI grade 12.5 cfm. Coating sets durability: uncoated for protected cavities, acrylic for sun without driving weather, PVC for harsh exterior exposure. Flame rating decides between the standard and UL94 HF-1 families. H-O cuts the result into finished parts and engineering recommends a grade with every quote. Skip to the quote form →

PVC coated reticulated polyurethane foam pads in three pore sizes, coarse to fine
PVC coated reticulated foam in three pore sizes. The open skeletal structure lets water weep and air flow while debris and insects stay out.
Quick Answer

Reticulated foam is a fully open-cell polyether polyurethane foam: reticulation removes the cell windows so the structure is almost all open path. It is specified by pores per inch (PPI), with volumetric air flow per ASTM D3574 as the measurable check, then by coating (uncoated, acrylic or PVC) and flame rating (standard or UL94 HF-1). H-O converts it into weep baffles, filters, pads, strips and covers.

Property values on this page are taken from the manufacturer datasheet published on each grade’s product page.

When To Spec What
  • Inside an extrusion, no sunlight: uncoated
  • Sun, but no driving weather: acrylic coated
  • Driving rain, dust or hail: PVC coated
  • Flame rating on the drawing: UL94 HF-1 family
  • UL 900 Class 2 filter media: FilterPore S-100X
How it works
  1. 1
    Send drawing
    Upload a DXF, STEP or PDF, or describe the baffle, filter or pad with its thickness and quantity.
  2. 2
    Grade review
    Engineering matches PPI, coating and flame rating to the job and confirms the grade with you.
  3. 3
    Prototype
    24-hour prototypes on in-house materials; otherwise samples typically 3–5 business days.
  4. 4
    Production
    Standard production runs ship about 2 weeks after drawing approval.
Grade finder

All 34 reticulated foam grades in one table

Five polyether polyurethane families in six pore sizes, plus FilterPore S-100X polyester. Every cell links to the grade’s product page with its full datasheet values, thickness list and FAQ.

FilterPore S-100X thermally reticulated polyester filtration foam, UL 900 Class 2 per its manufacturer: 10 PPI → 20 PPI → 30 PPI → 45 PPI →

Not sure where to start? The PPI chart and coating comparison below narrow it to one or two grades, or send the application and engineering will recommend one.

Pore size

Reticulated foam PPI chart: pore size, air flow and strength

PPI is the number of pores counted along one linear inch. More pores per inch means smaller openings, finer filtration and less air flow. In our range the drop is steady: 25.5 cfm at 10 PPI, 22 at 20, 18 at 30, 12.5 at 45 and 7.5 at 60 PPI.

Volumetric air flow by pore size for H-O reticulated foam grades Bar chart. Air flow per ASTM D3574 falls as pore count rises: 10 PPI 25.5 cfm, 20 PPI 22 cfm, 30 PPI 18 cfm, 45 PPI 12.5 cfm, 60 PPI PVC coated 7.5 cfm. Nominal pore pitch shown under each bar. AIR FLOW VS PORE SIZE · ASTM D3574 · FROM THE GRADE DATASHEETS 0 10 20 air flow, cfm 25.5 22 18 12.5 7.5 10 PPIpitch ≈ 2.5 mm 20 PPIpitch ≈ 1.3 mm 30 PPIpitch ≈ 0.85 mm 45 PPIpitch ≈ 0.56 mm 60 PPIPVC coated grade Pitch = 25.4 mm ÷ PPI, a geometric approximation of the spacing between pores, not a measured pore diameter.
Figure 1. Air flow falls as the pore count rises. Thickness, coating and how hard the part is compressed in service also change the flow you get in the assembly.
Acrylic coated reticulated foam squares in three pore sizes showing the coarse to fine cell structure
Acrylic coated foam, three pore sizes: the cells get finer as PPI rises.
Uncoated reticulated polyurethane foam pads in three pore sizes
Uncoated foam, three pore sizes, from coarse to fine.

Properties by pore size

GradeCell count (Crest)Air flow, ASTM D3574CFD at 25%Compression set at 50%Tensile, minElongation, minTear, minDensityThickness
10 PPI10 ±525.5 cfm ±4.50.30 psi min15% max5 lb/in100%2 lb/in1.4 lb/ft³1/4 to 2 in
20 PPI20 ±522 cfm ±3.50.50 ±0.10 psi15% max18 lb/in180%5 lb/in1.4 lb/ft³1/4 to 2 in
30 PPI30 ±518 cfm ±20.55 ±0.10 psi25% max20 lb/in180%5 lb/in1.4 lb/ft³1/4 to 2 in
45 PPI45 ±512.5 cfm ±20.65 ±0.10 psi25% max22 lb/in200%4.5 lb/in1.4 lb/ft³1/4 to 1 in
60 PPI, PVC coated60 ±57.5 cfm ±1.50.65 ±0.20 psi15% max30 lb/in200%4.0 lb/in1.9 lb/ft³1/4 to 2 in
60 and 80 PPI, other families55–65 / 65–80Published as ranges on the grade datasheets; see each grade page1/4 to 1 in

All values from the manufacturer datasheets on the grade pages, tested per ASTM D3574. At a given PPI the coated and UL94 HF-1 versions list the same air flow and compression values as the uncoated grade.

What the numbers mean for your part

  • PPI is a visual count; air flow is the measurement. The Crest visual standard is how the industry names pore size, and it carries a ±5 PPI tolerance. The datasheets point to volumetric air flow as the only quantifiable value for confirming PPI, so if flow matters, put the air flow value and tolerance on the drawing next to the PPI.
  • The foam is very soft. 0.30 to 0.65 psi to compress it 25% means a baffle or filter seats in its slot with very little force and will not bow a thin frame. It also means compression changes the part: squeezing open-cell foam closes its flow path, so size the part for a light fit rather than heavy interference.
  • Coarse grades are the most fragile. 10 PPI has the fewest struts per inch: 5 lb/in tensile and 2 lb/in tear, against 20 and 5 lb/in at 30 PPI. Keep narrow webs, thin bridges and long unsupported strips in mind when you design a 10 PPI part.
  • Coarse grades recover better. 10 and 20 PPI allow 15% compression set at 50% deflection; 30 and 45 PPI allow 25%. For a part that lives under compression, that is worth weighing against filtration.
  • Thickness works with PPI. Dirt-holding capacity and flow resistance both rise with thickness. A thicker coarse grade can beat a thin fine grade where you need both flow and capacity.

Typical starting points by application

ApplicationTypical PPIFamily
Residential window and door weep baffles30Uncoated in protected slots; coated where the baffle sees UV
Curtain wall and commercial windows30 (40 on high-rise)PVC coated
HVAC and air-conditioner filters20 to 30; 40 to 45 for equipment with more airflowAcrylic or PVC coated outdoors
Power switch and electrical enclosure vents45PVC coated, UL94 HF-1
Coarse pre-filters, maximum flow10 to 20By exposure
Restricted flow, finer filtration60 to 80By exposure; most families to 1 in thick
Structure and chemistry

How reticulated foam is made, and why it behaves the way it does

Ordinary flexible polyurethane foam is a mass of cells, each closed off by thin membranes called windows. Reticulation removes those windows.

In thermal reticulation the foam block is sealed in a chamber with a combustible gas mixture that is then ignited. The flame front passes through the block in a fraction of a second. The thin cell windows have very little mass and melt away; the thicker struts that frame each cell survive. What is left is a three-dimensional skeleton of struts, commonly described as roughly 97% open volume, with no closed cells to trap water or block air.

Close-up of uncoated reticulated foam pads showing the open skeletal cell structure
Close-up of uncoated reticulated foam. The struts left after reticulation form a fully open path for air and water.

That structure explains every use on this page. Air and water move through it with little resistance, so it drains and breathes. The strut network still has to be crossed by anything carried in the flow, so dust, debris and insects are caught on it. And because the struts are slender, the foam is light (1.4 lb/ft³ for most grades here) and compresses under almost no load.

Polyether or polyester

Polyether polyurethanePolyester polyurethane
Grades on this pageAll five uncoated, acrylic, PVC and UL94 HF-1 familiesFilterPore S-100X
Moisture and humidityBetter resistance to moisture and mildew; the usual choice for wet service such as weep bafflesCan hydrolyze in hot, humid service; keep it out of long-term wet heat
Typical strengthsStable in water and outdoor cavitiesGenerally stronger, with good resistance to oils and many solvents; widely used for filtration media
Coatings

Reticulated foam coatings: uncoated vs acrylic vs PVC

A coating is applied over the strut skeleton after reticulation. It thickens the struts rather than closing the pores, which is why the datasheets list the same air flow for the coated and uncoated version at each PPI. What the coating changes is how long the foam lasts where it is installed.

Uncoated polyurethane yellows and loses strength when it is left in sunlight, and the grade datasheets limit the uncoated foam to extrusions and cavities that are not exposed to UV. The black acrylic and PVC coatings shield the struts: both are rated Excellent after 252 hours of accelerated UV exposure per ASTM G154, a fluorescent-lamp weathering test.

20 PPI reticulated foam pads in uncoated and coated finishes
The same 20 PPI pore size in uncoated and coated finishes. The coating changes durability, not the listed air flow.
FamilyColorUV, ASTM G154 (252 h)Where it goesFlame rating
Uncoated (30 PPI)Charcoal gray to 30 PPI; black at 45 PPI and finerNot rated; keep out of sunlightInside extrusions and protected cavities; indoor filtersFlame-retardant version by special request; UL94 HF-1 uncoated family available
Acrylic coated (30 PPI)BlackExcellentSunlight without driving weather: commercial windows, outdoor HVAC filtersFlame-retardant version by special request
PVC coated (30 PPI)BlackExcellentHarsh exterior: driving rain, dust storms, hail; curtain wall weep baffles, outdoor loudspeaker coversUL94 HF-1 PVC coated family available
30 PPI acrylic coated reticulated foam pads

Acrylic: the economical UV upgrade

Adds UV resistance at lower cost than PVC. Choose it for parts that see the sun but are sheltered from direct weather.

30 PPI PVC coated reticulated foam pads

PVC: the most durable coating

The heaviest-duty option in the range and the one architects specify for exposed exterior parts. It is also the coating on the exposed-location UL94 HF-1 family.

30 PPI uncoated reticulated foam pads

Uncoated: the protected-location choice

The lowest-cost family and the right one when the part sits inside a frame or housing, out of the sun.

Flame rating and listings

UL94 HF-1 reticulated foam, and UL 900 for filter media

If a flame classification is on the drawing, choose the family that carries it rather than asking for a standard grade to be upgraded.

UL 94 tests foamed plastics in a horizontal burn and assigns one of three ratings: HBF, HF-2 and HF-1. HF-1 is the most demanding of the three: flaming has to stop quickly, the burned length is limited, and burning drips may not ignite the cotton indicator under the specimen. Two families carry it in every pore size from 10 to 80 PPI: uncoated UL94 HF-1 for protected locations and PVC coated UL94 HF-1 for exposed ones. A UL 94 rating applies at a stated thickness, so confirm that your part thickness is covered.

Air filter assemblies are judged to UL 900. FilterPore S-100X is listed to UL 900 Class 2 by its manufacturer in 10, 20, 30 and 45 PPI. The standard uncoated, acrylic and PVC grades offer a flame-retardant formulation by special request; ask with your RFQ if you need one.

Specifying

How to call out reticulated foam on a drawing

A complete callout names the chemistry, the pore size with its measurable check, the coating, the flame rating and the geometry. Here is one written for a curtain wall weep baffle.

Example callout

FOAM, RETICULATED POLYETHER POLYURETHANE, 30 PPI ±5 (CREST VISUAL), AIR FLOW 18 ±2 CFM PER ASTM D3574, PVC COATED, BLACK, UL94 HF-1, THICKNESS AND TOLERANCE PER DRAWING.
H-O GRADE: 30 PPI PVC COATED RETICULATED FOAM UL94 HF-1.

Five mistakes we see on reticulated foam drawings

  • PPI with no air flow value. Two lots can both read 30 PPI on the visual standard and still differ in flow. Add the air flow and tolerance when performance depends on it.
  • Uncoated foam where it will see the sun. It will discolor and lose strength. Move to acrylic or PVC coated.
  • Heavy interference fit. Squeezing the part closes its pores and cuts the flow you designed for.
  • Narrow webs in coarse grades. At 10 PPI a thin bridge has very few struts holding it together.
  • Flame rating added late. Switching to a UL94 HF-1 family after approval can mean re-qualifying the part. Decide it with the grade.
Where reticulated foam is used

Applications, with the reason the open-cell structure fits

The same skeleton does two jobs at once: it passes air or water and it stops what you do not want to pass. These are the places that combination is specified most.

Window, door and curtain wall weep baffles

A weep hole has to drain water out of a frame while keeping wind-driven rain, insects and drafts from coming in. A die-cut reticulated baffle seated in the weep slot does both.

Window and door systems → · Residential window and door components →

HVAC and air-conditioner filters

Washable, reusable filter pads and frames in 20 to 45 PPI, coated where the unit sits outdoors.

Filtration and venting →

Enclosure, generator and compressor ventilation

Vent openings on NEMA enclosures and generator or compressor housings need controlled air flow with dust, water and insect exclusion, often with a UL94 HF-1 rating.

Enclosure sealing and IP protection →

Loudspeaker and grille covers

Open cells pass sound with little loss while keeping dust and moisture off the driver. PVC coated grades hold up on outdoor speakers.

Acoustic isolation and sound control →

Fluid management and filtration

Pre-filters, wicks and flow media where liquid has to pass while particulate is held back. FilterPore S-100X covers filtration that needs a UL 900 Class 2 listing.

Fluid management and filtration →

Medical devices

Filter and fluid-path parts where the device maker qualifies the material for its program.

Medical and clean components →

What H-O does with it

From reticulated foam sheet to a finished baffle, filter or pad

The foam is made by the reticulated foam mill. H-O turns it into the part on your drawing, and engineering reviews every RFQ to recommend a pore size and coating.

ProcessBest forReticulated foam notes
Flatbed steel-rule die cutting (capability)Production weep baffles, filter pads, gaskets and framesClean through-cuts on open-cell foam; repeatable outlines at volume
CNC knife cutting (capability)Prototypes, revisions and large partsNo tooling, so a new outline can be cut straight from your file
Waterjet cutting (capability)Thick sections and large blocksShapes up to 5 in thick and 60 x 118 in on our CNC waterjet and digital cutting equipment
Slitting (capability)Strips and narrow widthsReticulated foam strips cut to width for frames, slots and channels
PSA lamination (capability)Parts that need to stay in place during assemblyPressure-sensitive adhesive on one face, supplied on a liner
Flexible 20 PPI acrylic coated reticulated foam pads standing on edge
Die-cut 20 PPI acrylic coated pads, flexed to show how easily the foam conforms to a slot or frame.

What to send with a reticulated foam RFQ

  • Drawing or model (DXF, STEP or PDF), or a sample part.
  • Job of the part: weep baffle, filter, vent cover, acoustic cover, wick or cushion.
  • Flow or filtration target: PPI, air flow value, or the pressure drop you can accept.
  • Exposure: protected cavity, sunlight, or harsh exterior weather.
  • Flame or listing requirement: UL94 HF-1, UL 900 Class 2, or none.
  • Thickness, adhesive and quantity: prototype count and annual volume.

Other porosities, from 4 to 100 PPI, can be sourced for special requirements. Tell us the target and we will confirm availability with the quote.

Engineering FAQ

Questions engineers ask about reticulated foam

Short answers drawn from the grade datasheets and the jobs we cut most often.

10 questions · click a question to expand its answer

What is reticulated foam?

Reticulated foam is flexible polyurethane foam that has been through reticulation, a process that removes the thin membranes (windows) between cells and leaves only the skeleton of struts. The result is a fully open structure, commonly described as roughly 97% open volume, that passes air and water while holding back dust, debris and insects. Pore size is stated in pores per inch (PPI).

How do I choose the right PPI?

Start from the job. 10 to 20 PPI passes the most air and water, 30 PPI is the usual starting point for window and door weep baffles, 20 to 45 PPI covers most HVAC filters, and 60 to 80 PPI restricts flow for finer filtration. Across our grades, air flow per ASTM D3574 falls from 25.5 cfm at 10 PPI to 12.5 cfm at 45 PPI and 7.5 cfm at 60 PPI.

Why specify air flow as well as PPI?

PPI is a visual count against the Crest standard and carries a tolerance of plus or minus 5 PPI. The grade datasheets note that air flow is the only quantifiable value for confirming PPI, so a drawing that depends on flow should state the air flow value and tolerance per ASTM D3574.

Does a coating reduce air flow?

Not on the published data. The coating is applied over the strut skeleton rather than across the pores, and the datasheets list the same air flow and compression values for the uncoated, acrylic coated and PVC coated grade at each PPI. The coating changes UV and weather durability.

Uncoated, acrylic or PVC coated?

Uncoated grades are for extrusions and cavities that do not see sunlight. Acrylic coated grades add UV resistance (rated Excellent after 252 hours per ASTM G154) for parts that see sun but not driving weather. PVC coated grades carry the same UV rating and are the most durable choice for harsh exterior exposure such as driving rain, dust storms and hail.

Which reticulated foam is UL94 HF-1 rated?

Two families: uncoated UL94 HF-1 for protected locations and PVC coated UL94 HF-1 for exposed ones, each in 10, 20, 30, 45, 60 and 80 PPI. HF-1 is the most demanding of the three UL 94 foamed-material ratings (HBF, HF-2, HF-1). For filter media that needs a UL 900 Class 2 listing, FilterPore S-100X polyester is listed by its manufacturer in 10, 20, 30 and 45 PPI.

Polyether or polyester reticulated foam?

The five uncoated, acrylic, PVC and UL94 HF-1 families are polyether polyurethane, which resists moisture and mildew better and suits wet service such as weep baffles. FilterPore S-100X is polyester, generally stronger and widely used for filtration, but it can hydrolyze in hot, humid service.

What temperature can reticulated foam take?

A service temperature range is not stated on these grade datasheets. Tell us the continuous and peak temperature with your RFQ and we will confirm suitability with the foam manufacturer before quoting.

What shapes can H-O cut from reticulated foam?

Weep and air baffles, filter pads and frames, strips, loudspeaker and grille covers, and any outline on your drawing. We die-cut production quantities, cut prototypes on CNC knife equipment without tooling, slit strips to width and add pressure-sensitive adhesive for mounting. Shapes up to 5 in thick and 60 x 118 in can be cut on our CNC waterjet and digital cutting equipment.

How fast can I get reticulated foam samples?

24-hour prototypes on in-house materials; otherwise samples typically ship in 3 to 5 business days, and standard production runs about 2 weeks after drawing approval.

Engineering review

Request a reticulated foam quote

Send the drawing, the flow or filtration target and where the part is installed. Engineering reviews every RFQ and recommends a pore size and coating.

Contact
Your application
Typical response in one business day. 24-hour prototypes on in-house materials; otherwise samples typically 3–5 business days; production in about 2 weeks. MOQ varies by material and part. Prefer to talk? Call (860) 469-1144.
Get Quote →