Specialty Silicones Explained: 14 Formulations and the Cure Systems Behind Them
A specialty silicone is a base VMQ or FVMQ polymer plus a deliberate change: a different side group, a functional filler, a cleaner cure, or a qualification program. This page explains the cure systems first, because they leave fingerprints on every property, then covers fourteen specialty families with what each changes, which property or document to evaluate, and the design risk that most often gets missed.
Part of the Silicone Materials guide. Start at the hub page for the forms, the selection matrix and the material families; this page goes deep on one topic.
Platinum cure gives clean, odorless, translucent material for medical and food grades; peroxide cure is the economical standard and needs a post-cure. On top of the cure, fillers and side groups create the specialty families: ceramic fillers for thermal pads, silver or nickel-graphite for EMI, trifluoropropyl groups for fuel resistance, flame packages for UL 94 V-0 and FST, low-volatile formulations for ASTM E595, and tested platinum grades for USP Class VI / ISO 10993 or FDA 21 CFR 177.2600. Every rating belongs to a specific grade and thickness, never to “silicone” in general. Skip to the quote form →

Specialty silicones are base silicone polymers modified for one requirement: fluorosilicone for fuel and oil, electrically conductive grades for EMI gaskets, thermally conductive ceramic-filled pads for heat sinks, flame-retardant grades rated UL 94 V-0 or FST-tested, low-outgassing grades passing ASTM E595, medical grades tested to USP Class VI or ISO 10993, food-contact grades meeting FDA 21 CFR 177.2600, plus high-temperature, antimicrobial, reinforced, high-tear, translucent and membrane grades. The cure system (platinum vs peroxide) decides purity, clarity and post-cure needs underneath all of them.
Property values are quoted from the source manufacturer TDS or the cited standard, not from H-O testing. H-O converts sheet and roll silicone; ratings belong to the specific grade and a finished assembly earns its own rating at the system level.
- Fuel, oil, hydraulic fluid: fluorosilicone (FVMQ)
- EMI gasket: conductive silicone, MIL-DTL-83528 Type
- Heat sink interface: thermally conductive pad, ASTM D5470
- Patient contact: platinum medical grade
- Aircraft, rail, switchgear flame duty: UL 94 V-0 / FST grade
-
1Send drawingUpload a DXF, STEP, or PDF, or describe the gasket, pad, or insulator and its environment. A sample part works too.
-
2Material reviewEngineering checks the candidate grade against the manufacturer TDS: closure force, compression set, service temperature, fluid exposure, flame or regulatory requirement, and adhesive compatibility.
-
3Prototype24-hour prototypes on in-house materials; otherwise samples typically ship in 3–5 business days for common die-cut configurations on materials we commonly convert. Made-to-order; MOQ varies by material and part.
-
4ProductionStandard production runs ship about 2 weeks after drawing approval, including kiss-cut-on-liner and laminated configurations. Expedited service available. Ongoing parts run with lot traceability and TDS records.
Platinum vs peroxide cure, HCR vs LSR, and why it matters to a converted part
The cure system is chosen by the silicone manufacturer, not the converter, but it leaves fingerprints on every property an engineer cares about: compression set, clarity, odor, extractables, regulatory eligibility, and how the sheet ages. A drawing that says “silicone, 50 Shore A” without naming the cure or the grade leaves those properties to chance.
| Attribute | Peroxide (free-radical) cure | Platinum (addition) cure | Condensation (RTV) cure |
|---|---|---|---|
| Mechanism | An organic peroxide (DCBP, dicumyl peroxide, or similar) decomposes at cure temperature and creates radicals that cross-link methyl and vinyl groups. | A platinum catalyst adds silicon-hydride cross-linker across vinyl groups; no leaving group. | Moisture-triggered condensation, usually tin-catalyzed; releases acetic acid, oxime, or alcohol. |
| By-products | Yes: acids and aromatic residues; DCBP leaves 2,4-dichlorobenzoic acid that can migrate to the surface as a white “bloom.” | None of consequence; volatile siloxanes only. | Acid, oxime, or alcohol during cure. |
| Post-cure | Required for stable properties: typically 2–4 h at 177–200 °C (350–400 °F) to drive off acidic by-products and stabilize properties. [27] | Optional; used to stabilize properties and remove volatiles for medical, optical, and low-outgassing grades. | Not applicable to sheet goods. |
| Typical products | Most commercial and mil-spec HCR sheet; most blown sponge; AMS 3302/3303/3304 grades (SSP352 is “peroxide catalyzed”). [22] | Medical and USP Class VI sheet (SSP2390, BISCO MS-1600, ElastaPro medical), LSR-molded sheet, BISCO cast foams, most translucent and optical grades. | RTV sealants and potting compounds; not a converting material. |
| Effect on compression set | Good after proper post-cure; poor if the sheet is not post-cured. | Good to excellent; the cast BISCO foams’ 2–5% set is partly a product of addition cure. | Not relevant. |
| Clarity, odor, taste | Slight odor possible; translucent grades can yellow. | Water-clear translucents; odorless and tasteless, which is why food and medical grades are usually platinum. | Acetic odor during cure. |
| Watch-outs | Bloom on unpost-cured stock; peroxide residues are a reason some regulatory grades exclude it. | Cure inhibition: sulfur, amines, organotin, and some nitrogen compounds poison platinum. Sheet is already cured when it reaches H-O, so this matters mainly to designers who bond, overmold, or pot around the part with other silicones. [28] | Shrinkage 2–5%; thin-section only. |
HCR, LSR, and the sheet the converter actually receives
HCR (high-consistency rubber) is a gum-like solid before cure. It is calendered into sheet, extruded into profiles, or compression-molded, and cured by peroxide or platinum. Virtually all solid and sponge sheet stock is HCR. LSR (liquid silicone rubber) is a pumpable two-part platinum system that is injection-molded; its cross-link network is more regular, elongation is often higher, and compression set is typically better than an equivalent peroxide HCR. LSR reaches converters mainly as molded sheet for medical and food grades. Cast cellular silicone (the BISCO HT/BF foams) is a liquid platinum system cast on a carrier. RTV silicones are sealants, not sheet.
Extrusion, injection molding, compression molding, calendering, casting, and compounding are the silicone manufacturer’s processes; they are described here only because they determine the properties of the sheet and roll stock H-O converts. H-O’s role is precision converting of the appropriate sheet and roll materials: die cutting, flash and CNC knife cutting, waterjet cutting, slitting, PSA lamination, kiss-cutting on liner, inspection, and kitting. Where a design needs an extruded profile or a molded part, H-O can route it through its partner network, with tooling lead times that differ from die-cut parts.
Practical rules for drawings
- Medical, food, and translucent parts: call out platinum cure (or the specific platinum-cured grade). It removes the peroxide-residue question from the regulatory file.
- Hot, permanently compressed gaskets in solid sheet: call out the compression-set requirement (ASTM D395, condition, and limit) so a non-post-cured peroxide sheet cannot be substituted.
- Parts that will be over-molded or bonded with a platinum RTV: tell the material supplier; residual sulfur or amine from a mating material can inhibit the cure of the adhesive, not of the sheet.
- Space, vacuum, and optical parts: ask for post-cured, low-volatile stock with ASTM E595 data; see low-outgassing silicone.
Specialty silicones: what each family changes, and what to verify
A specialty silicone is a base VMQ or FVMQ polymer plus a deliberate change: a different side group, a functional filler, a cleaner cure, or a qualification program. Each card below states what the family is for, which property or document to evaluate, and the design risk that most often gets missed. Fourteen families are covered; metal-detectable silicone has its own full section.
High-temperature silicone
Rule: “Silicone withstands 500 °F” is a slogan, not a specification. Ask for continuous rating, intermittent rating, and heat-aging retention data for the specific grade.
General-purpose silicone is commonly rated to about 200–230 °C continuous; BISCO® HT/BF foams list −55 to +200 °C; kSil® GP solids list −60 to 230 °C with 250 °C intermittent. Dedicated high-temperature solids publish heat-aging data rather than a single ceiling: H-O’s Extreme High-Temperature sheet reports retained tensile above 750 psi and retained elongation above 90% after 168 h at 300 °C, which is the kind of number a thermal engineer can design against. [4] [18] [7]
Heat aging in silicone is mostly oxidative hardening: durometer rises, elongation falls, and a compressed gasket loses recovery long before it chars. The rating that matters is the temperature at which the part still recovers, not the one it survives.
Flame-retardant silicone (UL 94, FST)
Rule: A UL 94 V-0 rating belongs to a grade at a tested thickness. It does not transfer to the assembly, and it says nothing about service temperature.
UL 94 V-0 requires afterflame of 10 s or less per specimen and 50 s or less total for the set, with no flaming drips that ignite cotton; HB, V-1, V-2 and the foam-specific HBF/HF-1/HF-2 categories are progressively less demanding. [12] All BISCO HT/BF foams carry V-0 and HF-1 under UL file E83967; kSil® V-0 sponge and V-0 70 solid, BISCO HT-6360 Fire-Safe solid, and SSP 502-40-V0 conductive silicone are V-0 examples in other forms. [4] [15]
Aircraft interiors add FAR 25.853: 60-second vertical burn (burn length ≤6 in, flame time ≤15 s) for most parts, and heat release (OSU 65/65) plus smoke density (Ds ≤200) for large cabin components. Rail uses EN 45545-2 or NFPA 130 with ASTM E162/E662. These are separate programs; a V-0 foam is not automatically an FST-qualified foam. [29]
Low-outgassing silicone
Rule: The NASA screen is TML ≤1.0% and CVCM ≤0.10% per ASTM E595. Most cellular silicone passes TML and fails CVCM; only specific low-volatile solid grades pass both.
ASTM E595 heats a specimen at 125 °C for 24 h under vacuum and weighs what leaves (total mass loss, TML) and what condenses on a 25 °C collector (CVCM). Condensables are the problem for optics, sensors, connectors, and vacuum chambers because they redeposit on cold surfaces. [13] BISCO HT-800 reports TML 0.98% and CVCM 0.25%; HT-820 reports 2.11% and 0.63%. Both fail the CVCM limit. H-O’s Low-Outgassing Silicone Sheeting (40–70 Shore A) lists TML ≤1.00% and CVCM ≤0.10% with NASA-STD-6016 compliance on its TDS. [4] [25] [30]
Electrically insulating silicone
Rule: Unfilled silicone is a good, temperature-stable dielectric, but a foam is not a barrier film. Use silicone where compliance and heat matter; use dedicated films where thin, high dielectric strength per mil matters.
Dielectric strength (ASTM D149) is thickness-dependent and is reported in V/mil or kV/mm. Representative TDS values: BISCO HT-800 foam 75 V/mil; HT-6240 transparent solid 386 V/mil; kSil® GP solids 23 kV/mm (about 580 V/mil) with volume resistivity 3×10¹⁵ Ω·cm; Bergquist® Sil-Pad® TSP 900 insulator 3,500–4,500 Vac at 0.007–0.009 in. [31] [32] [18] [32]
In switchgear, busbar, motor, and battery insulation, silicone competes with polyimide, aramid paper, polyester, and mica. Silicone wins on conformability, heat aging, and combined seal-plus-insulate duty; the films win on dielectric strength per mil, creepage in thin sections, and cost. H-O covers the film side on its busbar, transformer and motor insulation page.
Electrically conductive silicone (EMI/RFI)
Rule: Electrically conductive and thermally conductive silicone are different materials with different fillers. Specify by MIL-DTL-83528 Type (filler and polymer) or by grade, never by “conductive silicone.”
EMI elastomers load silicone or fluorosilicone with silver-coated copper, aluminum, glass, or nickel, with pure silver, or with nickel-graphite. MIL-DTL-83528 organizes them by Type: A (silver/copper, silicone), B (silver/aluminum, silicone), C and D (the fluorosilicone counterparts), M (silver/glass), and others, with typical volume resistivities of 0.004–0.012 Ω·cm and shielding effectiveness of roughly 90–110 dB (20 MHz–10 GHz) for the silver-filled types, per SSP. [33] [34] Nickel-graphite grades (SSP 502 series, BISCO EC-2130 at under 1 Ω·cm and 30 Shore A) trade conductivity for cost and softness. [35]
Grounding and shielding are separate functions. A gasket can shield without being a low-resistance ground path, and any conductive gasket introduces galvanic questions against aluminum and stainless flanges (see the galvanic compatibility chart). H-O’s conductive-elastomer catalog and cross-references live on the EMI/RFI shielding materials page.
Thermally conductive silicone (gap pads, insulator pads)
Rule: These are engineered silicone composites, not gasket silicone. Compare them by ASTM D5470 thermal impedance at your pressure and thickness, not by headline W/m·K.
Thermal interface pads load silicone with ceramic fillers (alumina, boron nitride) and often a fiberglass carrier. Bergquist® Gap Pad® TGP 3000 lists 3.0 W/m·K, Shore OO 30, 3,000 Vac breakdown, and −60 to 200 °C; TGP 5000 lists 5.0 W/m·K and 5,000 Vac; Sil-Pad® TSP 900 (0.9 W/m·K, 85 Shore A, 0.007–0.009 in) is the clamped-insulator class; Rogers/Arlon PROTECT® 1500FG lists 1.5 W/m·K with UL 94 V-0 on its H-O product page. [36] [32] [69] Soft gap fillers absorb stack tolerance; thin reinforced insulators win at flat, bolted joints.
Electronics, EV inverters, battery modules, and battery energy storage (BESS) racks are the main markets. Dielectric versions dominate because the pad usually sits between a live device and a grounded sink. H-O’s application guidance is on power module thermal management and the thermal resistance calculator.
Fluorosilicone (FVMQ)
Rule: Choose fluorosilicone when the seal sees fuel, oil, or non-polar solvent and still needs silicone’s low-temperature flexibility. Expect to pay for it in price, tear, and hot-air limit.
Replacing part of the methyl groups with trifluoropropyl groups makes the polymer resistant to hydrocarbon swelling: in one manufacturer comparison, general silicone swelled roughly 26–30% by volume in IRM 903 oil (150 °C, 70 h) while fluorosilicone stayed under 5%, and fluorosilicone in Fuel C swelled about 4%. [6] MIL-DTL-25988 covers the sheet grades (Type II) in Classes 1–4 and 40–80 Shore A, with continuous service to about 175 °C. [37] H-O’s FVMQ calendered sheet lists 40 Shore A, 1,200 psi, 600% elongation, and 17% swell in Fuel B. [38]
The trade-offs: fluorosilicone is a higher cost tier than VMQ, its upper temperature is lower (about 175–200 °C), compression set on sponge grades is higher (Norseal® R10490 sponge lists 25%), and tear can be lower. It is the aerospace default for fuel-tank access, hydraulic zones, and engine-bay seals, and the conductive Types C/D/F of MIL-DTL-83528 use it as the base polymer.
Medical and biocompatible silicone
Rule: No silicone is “inherently biocompatible.” A medical grade is a specific platinum-cured formulation with a test file (USP Class VI and/or ISO 10993 endpoints) that you must confirm still applies after converting.
USP Class VI is a set of systemic, intracutaneous, and implantation screens on extracts; ISO 10993 is the device-level biological evaluation framework (cytotoxicity, sensitization, irritation, and so on) chosen by contact type and duration. Medical sheet is platinum-cured to avoid peroxide residues, is typically translucent or pigment-free, and carries sterilization data (autoclave, EtO, gamma or e-beam). H-O’s Medical Grade Silicone Sheeting lists USP Class VI, ISO 10993, European Pharmacopeia, and FDA 21 CFR 177.2600 across 30–70 Shore A with 1,100–1,350 psi tensile; SSP2390 and BISCO MS-1600 are platinum-cured alternatives in the catalog. [11]
Converted parts serve as device cushioning, enclosure and diagnostics seals, fluid-path gaskets, and skin-interface pads in wearables. H-O supports these programs with cleanroom converting and medical packaging and IQ/PQ documentation on request; the biocompatibility file stays with the device manufacturer.
FDA and food-contact silicone
Rule: “FDA silicone” means the formulation’s ingredients are listed in 21 CFR 177.2600 and the cured article meets its extractives limits. It is grade- and color-specific, and it is not the same as EC 1935/2004, 3-A, NSF, or WRAS.
21 CFR 177.2600 covers rubber articles intended for repeated use in contact with food and sets extraction limits (for example ≤20 mg/in² in distilled water over the first 7 h of reflux). [39] EC 1935/2004 is the EU framework regulation, usually paired with the German BfR XV recommendation for silicone; WRAS/BS 6920 covers drinking-water contact; 3-A covers dairy equipment design. Manufacturers list these separately for a reason. H-O’s catalog carries FDA white and translucent solids from 20 to 80 Shore A, gray BISCO HT-800 and BF-1000 foam with 177.2600 extractives statements, and Norseal® R10460 sponge with FDA 21 CFR 177.2600 on the TDS. [21] [4] [23]
Processing environments add sanitation duty: clean-in-place chemicals, steam, hot water, and mechanical cleaning. Silicone tolerates steam and most CIP alkalis well but not oil-rich products in the long term. Where fragments could reach the product stream, see metal-detectable silicone.
Antimicrobial silicone
Rule: An antimicrobial additive is intended to inhibit microbial growth on the material’s surface. It is not an infection-control device, and the claims must stay within the manufacturer’s test data and applicable biocide regulations.
Silicone Engineering’s neutraSil™ uses a silver-ion additive and cites JIS Z 2801 / ISO 22196 surface testing, reporting greater than 99.99% reduction of E. coli and Salmonella at 6 and 18 hours and a 48% (6 h) to greater than 99.99% (18 h) reduction of MRSA at 25 °C in its brochure; the manufacturer also lists FDA 21 CFR 177.2600 and EC 1935/2004 for the material. [40] Typical uses are hospital-equipment touch points, food-plant seals, and freezer and dairy gaskets, where surface hygiene between cleanings is the goal.
Limitations to state plainly: efficacy is measured under laboratory conditions on a clean surface; soil, biofilm, and cleaning chemistry change the outcome; and in the EU and US, treated-article rules (the Biocidal Products Regulation, EPA treated-article exemption) govern what may be claimed. Manufacturer literature reviewed for this page does not publish durability or wash-off data.
Glass- and fabric-reinforced silicone
Rule: Add a reinforcing ply when the part must hold its dimensions under load or survive repeated installation; accept that it will no longer stretch or conform like plain silicone.
A woven fiberglass or polyester ply is calendered into or between silicone layers. H-O’s Fiberglass Reinforced Silicone Sheeting lists 70 ±10 Shore A, a 0.014 in plain-weave fiberglass ply at 12.5 oz/yd², 1,300 psi minimum combined tensile, 35% maximum compression set, and AMS 3320 / AMS 3315 compliance. [41] Reinforced sponge (Norseal® R10450) and reinforced foam (BISCO IF-200, A2 fiberglass-reinforced sound barrier) apply the same idea to cellular materials.
Uses: large flange gaskets that must be handled without stretching, insulation and barrier blankets, high-temperature diaphragms, and gaskets with bolt holes that would tear in unreinforced sheet. Converting implication: the ply limits elongation, so die-cut features cannot rely on stretch-to-fit, and the cut edge exposes glass fibers that may need sealing in clean applications.
High-tear and high-strength silicone
Rule: When a gasket fails at a bolt hole, a thin web, or during assembly, the fix is mechanical properties, not more temperature resistance.
Ordinary silicone has modest tear strength (commercial sheet often 75–130 ppi Die B). High-tear grades reformulate the silica reinforcement and polymer to reach 150–250 ppi with elongation of 600–900%. A-A-59588 Class 3 defines the “tear and flex resistant” category; SSP’s Class 3 grades list roughly 1,240–1,490 psi tensile and 460–800% elongation. H-O’s medical and low-outgassing sheets list 170–205 ppi tear. [11] [30]
Clear and translucent silicone
Rule: “Translucent” is honest; “optically clear” is a specification. Most translucent sheet lets you see through it, not image through it.
Unpigmented platinum-cured silicone is naturally translucent to nearly transparent depending on filler and thickness. BISCO HT-6240 Transparent lists 40 Shore A, 1,040 psi, 112 ppi tear, and 386 V/mil dielectric strength; H-O’s translucent FDA grades cover 20–70 Shore A. [31] Uses include seals where a technician must see fluid or contamination behind the gasket, light-pipe and indicator gaskets, and medical parts where pigment migration is unwanted. Where true optical clarity, haze, or refractive index is specified, that is a separate optical-grade product with its own data.
Vacuum-forming and membrane silicone
Rule: Membrane silicone is specified by elongation and tear, not durometer, because the sheet is the tool.
Membrane grades are high-elongation, high-tear solid sheets used as the flexible diaphragm in vacuum presses, thermoforming, composite bagging, and solar-module lamination. Silicone Engineering’s kSil® VAC lists 780–900% elongation in translucent sheet up to 1,800 mm wide and 4 mm thick; a typical 40 Shore A press membrane lists about 8 MPa tensile and up to 700% elongation with service to 200 °C. [42] [43]
H-O’s role here is converting only: slitting membrane rolls to width, cutting blanks and frames to size, and adding edge reinforcement or attachment features. H-O does not perform vacuum forming or thermoforming.
Metal-detectable silicone
Rule: Use it where a gasket fragment in the product stream is a recall, and where an in-line metal detector or magnet separator is already part of the line.
A ferrous-detectable additive dispersed through the silicone lets appropriately configured detectors flag seal fragments. Food, beverage, dairy, and pharmaceutical processors use it in solid and sponge form. Because detection depends on the detector, the fragment, and the product, this family gets a full section with the manufacturer test conditions and the system-dependence caveat spelled out.
Questions engineers ask about this topic
Direct answers with the source. The same questions appear in the page’s structured data.
Is all silicone FDA-approved or food-grade?
No. “FDA-compliant” means a specific formulation and color uses ingredients listed in 21 CFR 177.2600 and the cured article meets its extractives limits (for example ≤20 mg/in² in water over the first 7 h). It is grade- and color-specific: gray BISCO HT-800 has an extractives statement; the black version is a different formulation. EC 1935/2004 with BfR XV (EU), WRAS (drinking water), 3-A (dairy), and NSF are separate programs. Specify the grade, color, and regulation on the drawing. [39] [4]
What is the difference between medical-grade and FDA-grade silicone?
FDA 21 CFR 177.2600 is a food-contact regulation about ingredients and extractables. Medical grade refers to biocompatibility testing: USP Class VI (systemic, intracutaneous, and implantation screens on extracts) and ISO 10993 endpoints chosen for the device’s contact type and duration. Medical sheet is platinum-cured to avoid peroxide residues and carries sterilization data. A silicone can be FDA-compliant without any biocompatibility testing, and a laminated adhesive needs its own file. H-O’s Medical Grade sheet lists USP Class VI, ISO 10993, European Pharmacopeia, and 21 CFR 177.2600 together. [11]
Platinum-cured vs peroxide-cured silicone: which should I specify?
Platinum (addition) cure leaves no acidic by-products, gives clear and odorless material, and is the default for medical, food, translucent, and low-outgassing grades; its catalyst can be inhibited by sulfur, amines, and tin in mating materials during bonding. Peroxide cure is the economical standard for commercial and mil-spec sheet and most sponge; it needs a post-cure (typically 2–4 h at 177–200 °C) to remove by-products and stabilize compression set, and unpost-cured sheet can bloom and harden. For hot, permanently compressed gaskets, specify the compression-set requirement rather than the cure system; for regulated parts, specify platinum. [27] [28]
Is silicone electrically conductive or insulating?
Unfilled silicone is an insulator: BISCO HT-800 foam lists 75 V/mil dielectric strength and 10¹⁴ Ω·cm volume resistivity; kSil® GP solids list 23 kV/mm and 3×10¹⁵ Ω·cm. Electrically conductive silicone is a separate product loaded with silver-coated or nickel-graphite fillers to reach 0.004–1 Ω·cm for EMI gaskets (MIL-DTL-83528 Types). Thermally conductive silicone gap pads are a third product, ceramic-filled and usually still electrical insulators. Specify the function and the test, never “conductive silicone” alone. [4] [33]
What is high-temperature silicone rated to?
It depends on the grade and on whether the figure is continuous or intermittent. General silicone is commonly rated about 200–230 °C continuous (BISCO® foams −55 to +200 °C; kSil® GP −60 to 230 °C, 250 °C intermittent). Dedicated high-temperature solids publish heat-aging retention instead of a ceiling: H-O’s Extreme High-Temperature sheet keeps over 750 psi tensile and over 90% elongation after 168 h at 300 °C. Design to the continuous rating and to retained properties, and remember that PSA and liners are usually the lower limit. [7] [18]
Does UL 94 V-0 silicone meet FAR 25.853?
Not automatically. UL 94 V-0 is a small-flame test on a specimen at a stated thickness. FAR 25.853 Appendix F is a separate aircraft-interior program: a 60- or 12-second vertical burn for most parts, plus OSU heat release and smoke density for large cabin components. Rail uses EN 45545-2 or NFPA 130 with ASTM E162/E662. Many silicone foams carry both V-0 and FAR data, but each is a separate test report for a specific grade and thickness, and the finished assembly earns its own qualification. [12] [29]
What is low-outgassing silicone and who needs it?
Silicone formulated and post-cured so that very little condensable material leaves it under vacuum and heat. The NASA screen per ASTM E595 is total mass loss ≤1.0% and collected volatile condensable material ≤0.10%. Most cellular silicone passes TML and fails CVCM (BISCO HT-800: 0.98% / 0.25%); H-O’s Low Outgassing Silicone Sheeting lists TML ≤1.00% and CVCM ≤0.10%. Spacecraft, vacuum chambers, optics, sensors and connectors need it, and the adhesive must be screened too. [13] [30]
What is fluorosilicone used for?
Seals that see fuel, oil, hydraulic fluid or non-polar solvent and still need silicone’s cold flexibility: fuel-tank access, hydraulic zones, engine bays, and fluid-exposed EMI gaskets (MIL-DTL-83528 Types C, D and F use it as the base polymer). Sheet grades are specified to MIL-DTL-25988 Type II in 40–80 Shore A with continuous service to about 175 °C. It costs more than VMQ, has a lower hot-air ceiling and higher compression set in sponge form, and gives no advantage against water, steam, ketones or brake fluid. [37] [6]
References
Every quantitative claim on this page traces to one of the sources below. Reference numbers are shared across all eight pages of the Silicone Materials guide so a value cited as [4] here is the same source as [4] on any other page. Values change between data-sheet revisions; the revision on file at publication governs.
Show all 30 sources cited on this page tap to expand
Rogers BISCO® HT-800 data sheet (Pub. 180-070)
Density 22 pcf; CFD 6–14 psi (9.7 typ.); compression set 2.4% typ.; −55 to +200 °C; ASTM D746 −55 °C; UL 94 V-0/HF-1 file E83967; 75 V/mil; 10¹⁴ Ω·cm; 0.076 W/m·K; TML 0.98% / CVCM 0.25%; AMS 3195; FDA 21 CFR 177.2600 extractives (gray). rogerscorp.com (PDF) · H-O product page
Shin-Etsu silicone rubber performance data
Oil-swell comparison: general silicone +26–30% volume in IRM 903 (150 °C/70 h) vs fluorosilicone under 5%; fluorosilicone in Fuel C about +4%; compression-set and heat-aging ranges by grade. shinetsusilicone-global.com (PDF)
H-O TDS: Extreme High-Temperature Grade Silicone Sheeting
55/60 Shore A; 1,050/1,200 psi; 450%; heat aging 168 h at 300 °C: retained tensile >750 psi, elongation >90%, tear >70 ppi. H-O product page · TDS (PDF)
H-O TDS: Medical Grade Silicone Sheeting
30–70 Shore A; tensile 1,100–1,350 psi; elongation 600–900%; tear 170–205 ppi (Die B); USP Class VI, European Pharmacopeia, ISO 10993, FDA 21 CFR 177.2600. H-O product page · TDS (PDF)
UL 94, Standard for Tests for Flammability of Plastic Materials
HB, V-2, V-1, V-0, 5VA/5VB and foam classes HBF/HF-1/HF-2; V-0 afterflame ≤10 s per specimen, ≤50 s per set, no flaming drips igniting cotton. ul.com
ASTM E595 and NASA outgassing criteria
125 °C, 24 h, vacuum, 25 °C collector; screening pass TML ≤1.0% and CVCM ≤0.10%. NASA GSFC outgassing database
H-O product pages: kSil® V-0 KSV001 and KSV004 sponge
KSV001 V-0 Super Soft: 10.0 pcf, 2.8 psi at 25%, UL 94 V-0, −76 to 446 °F. KSV004 Medium: 24.3 pcf, 9.0 psi at 25%. KSV001 · KSV004 · manufacturer: silicone.co.uk
kSil® GP solid sheet TDS (Silicone Engineering, SE-NEU-V7-2019) and H-O GP50 page
GP30–GP80: tensile 7–10 MPa, elongation 215–525%, tear 16–23 N/mm, compression set 9–25% (ISO 815, 24 h/150 °C) and 10–22% (ASTM D395 B, 22 h/300 °F); −60 to 230 °C (250 °C intermittent); 0.24 W/m·K; 23 kV/mm; 3×10¹⁵ Ω·cm; FDA 21 CFR 177.2600, BfR XV, WRAS, FAR 25.853. TDS (PDF, distributor-hosted) · silicone.co.uk/ksil · H-O GP50 page
H-O TDS: 50 Durometer FDA Grade Solid Silicone
SG 1.33; 50 ±5 Shore A; 950 psi; 600%; tear 105 ppi; −80 to 450 °F; FDA 21 CFR 177.2600; 1/32–1/2 in white. H-O product page
SSP: AMS silicone specifications map and SSP352
AMS 3301 (40 A), 3302 (50), 3303 (60), 3304 (70), 3305 (80), 3325 (fluorosilicone 60), 3332 (extreme low temperature 20); SSP352 (AMS 3303) 60 A, 1,000 psi, 350%, 75 ppi, peroxide cure. sspinc.com/ams-silicones · sspinc.com/products/ssp352
Saint-Gobain Norseal® R10460 sponge TDS (Form 1349)
29 pcf; CFD 10 psi; compression set 5% (D1056); −100 to +500 °F; UL 94 HBF; water absorption under 5%; AMS 3195, MIL-R-6130 Type II, ASTM D6576 Type 2, FDA 21 CFR 177.2600. saint-gobain.com (R10480M page) and the R10460 TDS on file.
Rogers BISCO® HT-820 data sheet (Pub. 180-071)
24 pcf; CFD 12–20 psi (15.3 typ.); compression set under 5%; 0.09 W/m·K; 66 V/mil; TML 2.11% / CVCM 0.63%; AMS 3196; 0.031–0.250 in gray. rogerscorp.com
Dow: Post-Curing of Silicone Elastomers
Peroxide post-cure removes 2,4-dichlorobenzoic acid bloom and related residues; typical schedules 2 h at 177 °C, 2–4 h at 200 °C; for platinum-cured parts, curing continues after molding so hardness rises and elongation falls until post-cured; peroxide post-cure is primarily to drive off acidic by-products. rdabbott.com (PDF)
Silicone cure systems: platinum, peroxide, condensation (BIO Corporation)
By-products, post-cure needs, shrinkage (platinum under 1%, peroxide and condensation 2–5%), and platinum inhibitors (amines, sulfur, organotin, nitrogen compounds). bio-corporation.com
14 CFR Part 25, Appendix F (FAR 25.853)
Part I vertical burn (60 s: burn length ≤6 in, flame time ≤15 s; 12 s: ≤8 in); Part IV heat release (peak ≤65 kW/m², total ≤65 kW·min/m²); Part V smoke (Ds ≤200 at 4 min). ecfr.gov
H-O TDS: Low Outgassing Silicone Sheeting
40–70 Shore A; 1,100–1,250 psi; 650–900%; tear 175–200 ppi; TML ≤1.00%, CVCM ≤0.10% (ASTM E595); NASA-STD-6016; FDA 21 CFR 177.2600. H-O product page · TDS (PDF)
Rogers BISCO® HT-6000 series and HT-6240 data sheet (Pub. 180-093)
HT-6240 Transparent: 40 ±5 Shore A; 1,040 psi; 325%; 112 ppi; SG 1.07; 386 V/mil; −55 to +200 °C. HT-6360 Fire-Safe: 60 A; UL 94 V-0; ASTM E162/E662. rogerscorp.com
Henkel Bergquist® Sil-Pad® TSP 900 TDS
0.9 W/m·K; 85 Shore A; 3,500–4,500 Vac; 0.007–0.009 in; −60 to 180 °C; thermal impedance 1.13 °C·in²/W at 50 psi; UL 94 V-0. henkel.com (PDF)
SSP: MIL-DTL-83528 QPL conductive elastomers
Type map (A: SSP2569-65 Ag/Cu; B: SSP2368-65 Ag/Al; C: SSP2573-75; D: SSP2486-70; K: SSP2571-85); SSP page values: Type A (SSP2569-65) 0.004 Ω·cm and 110 dB; Type B 0.008 Ω·cm, 100 dB; Type D 0.012 Ω·cm, 90 dB; Type K 110 dB (20 MHz–10 GHz). sspinc.com
Parker Chomerics elastomer selector guide
CHO-SEAL® 1215 (Ag/Cu silicone) 0.004 Ω·cm max; 1285 (Ag/Al) 0.008; 1287 (Ag/Al FVMQ) 0.012; 6502 (Ni/Al) 0.150; temperature ranges by grade. Used as industry cross-reference only. parker.com (PDF)
Rogers BISCO® EC-2130 data sheet (Pub. 180-034)
Nickel-graphite; volume resistivity under 1.00 Ω·cm; SE 105/108/108/103 dB at 100 MHz/600 MHz/1 GHz/10 GHz; 30 ±5 Shore A; compression set 10% max (D395 B, 70 °C/70 h/25%); −62 to +200 °C. rogerscorp.com (PDF)
Henkel Bergquist® Gap Pad® TGP 3000 and TGP 5000 TDS
TGP 3000: 3.0 W/m·K, Shore OO 30, 3,000 Vac, 0.254–3.175 mm, −60 to 200 °C, 3.2 g/cm³, UL 94 V-0. TGP 5000: 5.0 W/m·K, Shore OO 35, 5,000 Vac, 3.6 g/cm³. henkel-adhesives.com (TGP 3000) · TGP 5000
SSP: Understanding MIL-DTL-25988 fluorosilicone
Types I–IV (Type II sheet/roll), Classes 1–4, Grades 40–80 Shore A; continuous −55 to +175 °C, short-term to +200 °C. sspinc.com
H-O product page: Fluorosilicone (FVMQ) Calendered Sheet
40 Shore A; SG 1.41; 1,200 psi; 600%; Fuel B swell 17%; −80 to 450 °F. H-O product page
21 CFR 177.2600, Rubber articles intended for repeated use
Permitted substances (silicone with methyl, phenyl, vinyl, fluoro groups listed) and extractives limits: distilled water ≤20 mg/in² first 7 h, ≤1 mg/in² next 2 h; n-hexane ≤175 mg/in² first 7 h, ≤4 mg/in² next 2 h. ecfr.gov
Silicone Engineering: neutraSil™ antimicrobial silicone
Silver-ion additive; JIS Z 2801 / ISO 22196; brochure efficacy at 25 °C (E. coli and Salmonella >99.99% at 6 and 18 h; MRSA 48% at 6 h, >99.99% at 18 h); FDA 21 CFR 177.2600 and EC 1935/2004. silicone.co.uk/neutrasil · brochure (PDF, 2018)
H-O TDS: Fiberglass Reinforced Silicone Sheeting
70 ±10 Shore A; 0.014 in fiberglass ply, 12.5 oz/yd²; 1,300 psi min combined tensile; compression set 35% max; AMS 3320, AMS 3315; FDA 21 CFR 177.2600 ingredients. H-O product page · TDS (PDF)
Silicone Engineering: kSil® sheeting and kSil® VAC membranes
kSil solid 30–80 Shore A, 0.3–20 mm, to 1,800 mm wide; sponge 150–600 kg/m³, 2–45 mm, closed cell; −60 to 230 °C; kSil VAC elongation 780–900%, to 4 mm, translucent. Current family list: kSil, kSil VAC, kSil V-0, metectSil, neutraSil, expanSil, suraSil. silicone.co.uk/ksil · kSil VAC · our materials
Vacuum-press silicone membrane SM-40 (representative TDS)
40 Shore A; tensile 8 N/mm²; elongation up to 700%; 1–3 mm; to 200 °C. Representative of membrane-grade sheet; not an H-O catalog item. vacuum-presses.com
H-O product page: Rogers / Arlon PROTECT® 1500FG thermal pad
PROTECT 1500FG: 1.5 W/m·K thermally conductive silicone / fiberglass pad; dielectric strength above 19 kV/mm; UL 94 V-0; 7–20 mil. h-oproducts.com/product/protect-1500fg (values per the Arlon TDS hosted on the page)
Need help selecting a silicone?
Send H-O your drawing, operating temperature, environment, compression requirements, regulatory requirements, adhesive needs, and expected quantity. Our team reviews the application against current manufacturer data and helps identify appropriate material constructions for prototyping and production. We typically respond within one business day.
See also: the rest of the Silicone Materials guide
The guide is one hub and seven topic pages that share one set of sources and one set of numbers.